EEWORLDEEWORLDEEWORLD

Part Number

Search

2644LPA7/133001L220V3/6

Description
Rocker Switch, On-on-on, 5A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2644LPA7/133001L220V3/6 Overview

Rocker Switch, On-on-on, 5A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2644LPA7/133001L220V3/6 Parametric

Parameter NameAttribute value
Body length or diameter32.004 mm
Terminal length0.437 inch
Actuator length0.394 inch
body width24.9936 mm
body height16.9926 mm
Other features220VAC GREEN FLUROSCENT LAMP
Contact (DC) maximum rated R load5A@24VDC
Contact functionON-ON-ON
Dielectric withstand voltage2500VRMS V
Insulation resistance1000000000 Ω
Switch typeROCKER SWITCH
Actuator typeROCKER
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
Maximum contact current (DC)5 A
Contact resistance0.01 mΩ
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
Reach Compliance CodeCompliant
Country Of OriginUK
ECCN codeEAR99
Is SamacsysN
YTEOL7.3
Objectid313130986
Actuator materialPOLYAMIDE
center contact materialSILVER
End contact materialSILVER
Shell materialPOLYAMIDE
Installation featuresPANEL MOUNT
surface mountNO
Termination typeSCREW
Actuator colorGREEN
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
The International Telecommunication Union gives a preliminary definition of IPTV
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:59[/i]The International Telecommunication Union gives a preliminary definition of IPTV 2006-8-9The International Telecommunication Unio...
hkn Mobile and portable
Netizens' chat: I heard that some 103 have increased to 100, and 407 is already 70 per piece.
This morning I saw an engineer say in the group:——I heard that some 103 have increased to 100 ——407 is already 70 a pieceI've been hearing about price increases recently, and I'm curious. I feel like ...
nmg Domestic Chip Exchange
Help: 430 assembly division program, 32-bit/16-bit
I am a beginner in 430 and found that there is no division instruction in assembly language. Can the moderator and other experts provide a 32-bit/16-bit division assembly program? Thank you....
carmack Microcontroller MCU
R5F10AGC MCU automatic reset
Is anyone using this IC? It automatically resets when powered on....
新新之家 Renesas Electronics MCUs
Kinetis DAC module (Part 2)
4. DAC Control Register 0 (DACx_C0)l DACEN: DAC enable.DACEN=0: DAC is disabled;DACEN=1: DAC enabled.l DACRFS: DAC reference selection.DACRFS=0: select DACREF_1 as the reference voltage;DACRFS=1: Sele...
bluehacker NXP MCU
How to read the clock counter block diagram in the data sheet?
How do I read the clock counter block diagram in the data sheet? I don't understand...
QWE4562009 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2132  345  968  1255  1717  43  7  20  26  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号