EEWORLDEEWORLDEEWORLD

Part Number

Search

412-12-T3

Description
Rotary Switch, 12 Positions, SP12T, Latched, 50A, 20VDC, Screw Terminal, Shaft Type Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size146KB,2 Pages
ManufacturerOhmite
Websitehttps://www.ohmite.com
Download Datasheet Parametric View All

412-12-T3 Overview

Rotary Switch, 12 Positions, SP12T, Latched, 50A, 20VDC, Screw Terminal, Shaft Type Actuator, Panel Mount

412-12-T3 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator typeSHAFT TYPE
body height193.7 mm
Body length or diameter108 mm
Contact (AC) maximum rated R load50A@300VAC
Maximum contact current (AC)50 A
Maximum contact current (DC)50 A
Contact (DC) maximum rated R load50A@20VDC
Maximum contact voltage (AC)300 V
Maximum contact voltage (DC)20 V
Graduation angle30 deg
Manufacturer's serial number412
Installation featuresPANEL MOUNT
Number of positions12
Number of switching segments3
surface mountNO
Switch actionLATCHED
switch functionSP12T
Switch typeROTARY SWITCH
Termination typeSCREW
Base Number Matches1
Power Tap Switches
High-current, Non-shorting Type
Model 711
SPECIFICATIONS
Material
Body:
Ceramic, arc-proof
(models 212, 312, 412, 608).
Compression Molded Polyester
(model 111). Melamine Phenolic
(model 711)
Contacts:
Silver alloy. Common
contact is rounded for assured
seating. Self-cleaning with built
in wiping action.
Terminals:
Soldering. 711 also
accepts quick connectors; 412,
#10 screws; 608, 0.25” bolts.
Mounting
Typical
ceramic style
Typical
tandem model
Model 711:
Using
3
/
8
-32 bushing
for
1
/
8
” thick maximum panel.
Four non-turn lug positions are
possible on the single, unen-
closed switch. Recesses in body
of switch permit positioning of
non-turn washer at “12, 3, 6 and
9 o’clock.”
3
/
16
“ hole for non-turn
washer. Shaft
1
/
4
Model 111:
For
1
/
4
” panel, maxi-
mum, using
3
/
8
-32 bushing and
hex nut. A
3
/
16
” hole is required
for the non-turn washer. Shaft
1
/
4
Model 212:
Using
3
/
8
-32 threaded
bushing and hex nut. A
5
/
32
” hole
is required for the non-turn pin.
Shaft
1
/
4
Model 312:
For
1
/
4
” panel, maxi-
mum, use three 10-32 flat-head
machine screws
3
/
8
” long. Shaft
1
/
4
Model 412:
For
1
/
4
” panel, maxi-
mum, use three 10-32 flat-head
machine screws
3
/
8
” long. A
5
/
16
” hole in panel is required for
shaft.
Model 608:
For 1” panel, maxi-
mum, three flat-head machining
screws
1
/
4
-20, 1
1
/
4
” long. Drill
a
7
/
16
” hole in panel for shaft.
Shaft
3
/
8
NOTE:
Since all tap switches are
electro-mechanical devices, they
are subject to wear and, there-
fore, have a finite life.
Overall
Rating
Rating Max. no. Diameter
Model
(AC)
(DC)* of taps (max., in./mm)
711
7A 125V
7A 20V 11
1.56 /
39.6
111
15A 125V 15A 20V 11
2.19 /
56
212
20A 150V 20A 20V 12
2.25 /
57
312
30A 300V 30A 20V 12
3.31 /
84
412
50A 300V 50A 20V 12
4.25 /
108
608
100A 300V 100A 20V
8
6.25 /
159
Depth behind panel (in./mm)
Shaft
single
2 in tandem
3 in tandem
Torque
13
/
16
/
20.6
1
25
/
32
/
45.2
2
15
/
32
/
62.7
7-12 oz.-in.
1
/
8
/
28.7
3
/
4
/
69.9
1
2
1.5-3.8 in.-lbs.
1
3
/
4
/
44.5
4
3
/
16
/
106.4
6
3
/
16
/
157.2
3-7 in.-lbs.
1
/
4
/
57.2
5
/
8
/
117.5
2
4
7 /
177.8
3-7 in.-lbs.
2
7
/
16
/
61.9
5
1
/
32
/
127.8
7
5
/
8
/
193.7
3-8 in.-lbs.
5
/
16
/
84.1
13
/
16
/
173.0
5
/
16
/
261.9
3
6
10
25-35 in.-lbs.
*non-inductive load
All dimensions for reference only; consult factory for details.
Ohmite power Tap Switches
(high power rotary switches)
are constructed to provide
dependable, convenient
operation.
All Ohmite tap switches,
from 15 to 100 amps, have
ceramic arc-proof bodies and
metal alloy contacts. Their
all-soldered and all-riveted
construction assures mechani-
cal and operational integrity.
Even the smallest Ohmite Tap
Switch, rated at 7 amps, has
a reinforced non-metal body
and solid metal alloy contacts.
These units feature high cur-
rent handling capability in a
small package.
FEATURES
• “Slow-breaking, Quick-make”
action proved best for switching
AC current.
• Non-shorting type disconnects
previous circuit before establish-
ing contact for succeeding tap.
• Ceramic and metal construction
provides resistance to arcing,
burning and charring.
• Tandem assemblies available as
standard models.
• UL listed for models 111, 212,
312 and 412
• RoHS compliant product avail-
able Jan. 2006 Add “E” suffix to
part number to specify.
S TA N D A R D PA RT N U M B E R S F O R P O W E R TA P S W I T C H E S
Model 711
7A - 125V
711-
*
-T3
3 in tandem
711-
*
-T2
2 in tandem
Single unit
Model 111
15A - 125V
111-
*
-T2
2 in tandem
Single unit
Model 212
20A - 150V
212-
*
-T3
3 in tandem
212-
*
-T2
2 in tandem
Single unit
Model 312
30A - 300V
312-
*
-T3
3 in tandem
312-
*
-T2
2 in tandem
Single unit
Model 412
50A - 300V
412-
*
-T3
3 in tandem
412-
*
-T2
2 in tandem
Single unit
Model 608
100A - 300V
608-
*
-T2
2 in tandem
608-
*
-T3
3 in tandem
Single unit
608-
*
Number of taps
*
Number of taps
*
3
4
5
6
7
8
Total rotation
711-
*
111-
*
212-
*
312-
*
3
4
5
6
7
8
9
10
11
12
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
412-
*
80°
120°
160°
200°
240°
280°
Check product availability at
www.ohmite.com
See page 82 for knobs,
dials, and other hardware
= Non-standard values subject to minimum handling charge per item
*
Insert number of taps at asterisk for complete part number (e.g. 111-3-T2)
80
Ohmite Mfg. Co.
1-866-9-OHMITE • Int’l 1-847-258-0300 • Fax 1-847-574-7522 • www.ohmite.com • info@ohmite.com
Total rotation
Wuhan Recruitment_Urgent recruitment of hardware engineers
1. Hardware Engineer (Urgent) Job Requirements: 1. Bachelor degree or above, major in communication, electronics, computer, more than 1 year of hardware development experience. College degree, more th...
岚裳 Embedded System
[Sipeed LicheeRV 86 Panel Review] 6-Waft Graphical Interface Development Test (Part 1)
Waft (WebAssembly Framework for Things) is a high-performance application development framework for AIoT. It was developed by Alibaba engineers and is based on WebAssembly and self-developed rendering...
DDZZ669 Domestic Chip Exchange
CPU on-chip register read and write
Dear experts, I recently encountered a problem about reading and writing CPU registers. Please help me. In the bootloader, I tried to write the control registers in the CPU, but I couldn't write succe...
huangveijun Embedded System
Different 51 tutorials 5 Write a real... small program
Earlier, I finished talking about the addressing mode and instruction system of the 51 microcontroller, as well as several basic internal resources that the traditional 8051 has (the so-called traditi...
辛昕 51mcu
nioss problem
I have built a NIOSS2 minimum system. The hardware platform was compiled successfully. The software used was HELLO_LED in the template. After compiling, it was downloaded into the FPGA, but it did not...
wenhuawu FPGA/CPLD
lwip implements GPRS communication example code
My platform is S3C2410 (ucos-ii) + MC35I. I have ported LWIP1.3.1 on UCOS, but I don't know how to use the given functions in LWIP1.3.1 to implement GPRS communication. Does anyone have relevant code ...
cgl123456 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 213  1822  2389  456  2368  5  37  49  10  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号