EEWORLDEEWORLDEEWORLD

Part Number

Search

802-048Z112-201PSC-01B

Description
Circular Connector Adapter
CategoryThe connector    The connector   
File Size176KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

802-048Z112-201PSC-01B Overview

Circular Connector Adapter

802-048Z112-201PSC-01B Parametric

Parameter NameAttribute value
MIL complianceNO
GuidelineMIL
DIN complianceNO
IEC complianceNO
Filter functionNO
Maximum operating temperature200 °C
Minimum operating temperature-65 °C
Reach Compliance CodeCompliant
ECCN codeEAR99
Is SamacsysN
Objectid7049750598
Body/casing typeRECEPTACLE-RECEPTACLE
Connector typeCIRCULAR ADAPTER
Contact point genderMALE-FEMALE
Shell materialSTAINLESS STEEL
Total number of contacts12
Coupling typeTHREADED-THREADED
empty shellNO
Mixed contactsYES
OptionsHERMETIC
802-048 Ordering Information
Series 802 Hermetic Jam Nut Mount Bulkhead Feed–Thru Receptacles
feature
gold plated iron alloy contacts and compression glass dielectric material. The
316 series stainless steel connector shell provides excellent corrosion protection.
Available in PS, SP, PP and SS for PP or SS application, power applied to a given
contact on one end will result in power to contact directly opposite, regardless of
contact identification letter. DWV of contact size #23 is 500 VAC with sizes #20, #16
and #12 rated at 1800 VAC. Hermeticity is rated at: 1 x 10
-7
ccHe/sec @ 1 atmosphere
differential. 802-048 is designed to mate with Glenair 802 Series plugs
How To Order
Sample Part Number
Series
Shell Material and Finish
Shell Size - Insert
Arrangement
Contact Type
Jam Nut Side
Contact Type
Opposite Side
Keyway Position
(See Table I)
Panel Thickness
(See Table II)
O-ring Material
802-048
802-048
= Bulkhead Feed–Thru Hermetic Receptacle
Z1
= Stainless Steel / Passivated RoHS Compliant
ZL
= Stainless Steel / Nickel Plated
INC
= Inconel 600
See Table III
P
= Pin
S
= Socket
P
= Pin
S
= Socket
A
= Normal
B
= Pos. B
C
= Pos. C
D
= Pos. D
-01
= .125/.500
-04
= 1.500/2.00
-07
= 3.000/3.500
See Table IV
-02
= .500/1.00
-05
= 2.000/2.500
-08
= 3.500/4.000
E
= Pos. E
Z1
12-37
P
S
A
01
D
F
= Pos. F
-03
= 1.00/1.500
-06
= 2.500/3.000
Table I: Key Positions
Table II: Panel Thickness
Panel
Thickness
Code
-01
-02
-03
-04
-05
H Panel
Thickness
.125/.500
.500/1.000
1.000/1.5000
1.500/2.000
2.000/2.500
2.500/3.000
3.000/3.500
3.500/4.000
J Maximum
Length
1.750
2.250
2.750
3.250
3.750
4.250
4.750
5.250
Table III: Insert Arrangements
Shell Size
5
6
7
8
9
10
12
14
15
21
Insert Arrangement(s)
-3
-1, -4, -6, -7, -23
-1, -10, -25
-1, -2, -13, -28, -200
-4, -19, -200, -201, -210
-2, -5, -26, -200, -201, -202
-2, -3, -7, -37, -200, -201, -220
-2, -5, -12, -55, -235
-3, -7, -14, -85, -241
-5, -12, -22, -130, -269
A° B°
Key Position
A
Normal
B
C
D
E
F
Key Rotation
150°
75°
95°
140°
75°
95°
210°
210°
230°
275°
275°
210°
-06
-07
-08
Table IV: O-ring Material
Designator
C
E
V
N
Material
Fluorosilicone, Conductive
EPDM
Viton
Nitrile
Designator
S
B
K
Material
Silicone
Butyle Rubber
Kalrez
Dimensions in Inches (millimeters) are subject to change without notice.
© 2014 Glenair, Inc.
Series 80 Mighty Mouse
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
E-21
E-Mail: sales@glenair.com
Series 802
Series 802 AquaMouse™ Hermetic
Jam Nut Mount Bulkhead Feed–Thru
E
In a hard disk, is the area of each track the same? If not, what is the relationship between the capacity of each track?
In a hard disk, is the area of each track the same? If not, what is the relationship between the capacity of each track? Thank you...
XULAODA Embedded System
Rectifier technology and features
[size=4]In order to improve the range of input voltage and frequency and extend battery life, the POWERWARE UPS power supply three-phase input adopts the latest three-phase diode bridge rectifier + IG...
fish001 Analogue and Mixed Signal
I would like to ask an expert, when drawing a multi-layer board using PADS layout, how can the chip components be connected to the internal power layer (already divided)?
I would like to ask an expert, when using PADS layout to draw a multi-layer board, how can I connect the chip components to the internal power layer (the power layer has been divided), and I need deta...
Guilinlinxi PCB Design
z-stack routing table
Is the routing table code in the protocol stack open? How can I get the routing table data? Thank you very much......
烛坤12 RF/Wirelessly
Looking for a cheap board that can be used to program LabVIEW
I want to buy a cheap board that can be used to program LabVIEW. I don't know which board is better. I heard that LM38S8962 can be used....
paopaofan Buy&Sell
Show the process of WEBENCH design + peak current adjustable circuit design
Use WEBENCH to design a peak current adjustable DC-DC circuit. It is convenient to use in the circuit design process and can adjust the output peak current....
hanskying666 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1813  1366  535  1887  1432  37  28  11  38  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号