EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS150AF-12/J

Description
AC-DC Regulated Power Supply Module, 150W,
CategoryPower/power management    The power supply circuit   
File Size589KB,4 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS150AF-12/J Overview

AC-DC Regulated Power Supply Module, 150W,

ZWS150AF-12/J Parametric

Parameter NameAttribute value
Package formMICROELECTRONIC ASSEMBLY
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Package body materialUNSPECIFIED
encapsulated codeXMA
Package shapeRECTANGULAR
Is it Rohs certified?Yes
Objectid7212138011
package instruction,
Reach Compliance CodeCompliant
ECCN codeEAR99
Is SamacsysN
YTEOL0
Ripple voltage (main output)0.05303 Vrms
Maximum total power output150 W
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Efficiency (main output)79%
Number of functions1
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
JESD-30 codeR-XXMA-X
CertificationCE, CSA, UL
Nominal input voltage100 V
Maximum output current12.5 A
Maximum output voltage13.2 V
Minimum input voltage85 V
Output times1
Minimum output voltage10.8 V
Nominal output voltage12 V
surface mountNO
Maximum input voltage265 V
length222 mm
Maximum seat height38 mm
width75 mm
Maximum operating temperature70 °C
Minimum operating temperature-10 °C
• Universal Input (85 - 265VAC)
• Power factor Corrected
• Input transient Corrected
• Peak Power capability
• 2 year warranty
• High quality design
Key Market Segments & Applications
Factory Automation
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Gaming, Vending, Printers
ZWS-AF Series
50 - 150W
Single output power supplies
ZWS-AF Features and Benefits
Features
• Input Transient Protected
• 2 Year Warranty
• Power Factor Corrected
• Peak Power Capability
Test & Measurement
Light Industrial
Benefits
• Withstands Harsh Environments
• Low Cost of Ownership
• Supports Global Use
• Can Drive High current Start Up Devices
Specifications
MODELS
ITEMS
AC Input Voltage range
DC Input Voltage range
Input Current (Typ)
Inrush Current
Power Factor
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection
Hold Up Time (Typ)
Leakage Current
Remote On / Off
Operating Temperature
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock (in packaging)
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
Notes:
(1) 100/200VAC (2) ZWS150AF -10 to 60°C, Derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
ZWS50AF
ZWS75AF
ZWS100AF
ZWS150AF
(1)
(1)
(4)
(1)
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3V & 5V :120mV, 12V to 24V : 150mV, 36V & 48V : 200mV
<0.02%/°C
>105% of Peak Current Capability
20
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, Derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Gnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Gnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL/CSA60950-1, EN60950-1, EN50178, CE Mark
Designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
Designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
2 Years
ZWS-AF Series
1
Show a very low exposed point
[i=s]This post was last edited by ljj3166 on 2015-6-9 20:23[/i] Please call the original poster the title person[b]This post will discuss some nipple exposure issues (administrator, please do not dele...
ljj3166 Microcontroller MCU
RF Design
RF Design...
jayson RF/Wirelessly
【Design Tools】Xilinx Virtex-4 LX160/200 Development Tool Kit
The Xilinx Virtex-4 LX160/200 Development Kit provides a complete hardware environment that allows designers to accelerate product launch. This kit targets Xilinx's innovative Virtex-4 Platform FPGA s...
ddllxxrr FPGA/CPLD
Barcode classification
1. Classification by code system 1) UPC code In 1973, the United States took the lead in applying UPC code in domestic commercial systems, and Canada also adopted UPC code in commercial systems. UPC c...
JasonYoo RF/Wirelessly
Why does tms320f240 frequently reset?
Why does ms320f240 frequently reset? But when the receiving or sending of serial communication is turned off, the reset will no longer occur?...
pch1881 DSP and ARM Processors
Looking to buy a 2440 or 2410 core board
I want to learn 2440 or 2410, but the prices online are too expensive. For those of us who have just graduated, we cannot afford it. If you have any that you don't need or are still collecting dust, p...
jlm Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 175  131  854  695  11  4  3  18  14  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号