Part Number

Search

U5334-020006-3.5BS

Description
Peizoresistive Sensor, 0Psi Min, 50Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U5334-020006-3.5BS Overview

Peizoresistive Sensor, 0Psi Min, 50Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U5334-020006-3.5BS Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknown
Maximum accuracy(%)0.1%
Other featuresPort Height = 9.9 MM
body height66.5 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type1/8-27 NPT
Maximum pressure range50 Psi
Minimum pressure range
Pressure sensing modeSEALED
Sensor/Transducer TypePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCONNECTOR
Base Number Matches1
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
Embedded Linux driver arm driver header file corresponding problem
I am developing an analog-to-digital conversion driver for an S3C2440 development board under Linux. I don't know where to put my .c and .h files. Can I put them anywhere?...
deeply Linux and Android
Very good! ! 7-inch serial port & video LCD display module M070AS26 with patent
Key Features ●Support dual-channel PAL/NTSC input, single-channel real-time display ●Character images can be superimposed at any position, support 4- level video zoom, and can store and play back 6 vi...
KINGEYE88 MCU
What data is stored behind the OS in WM's NAND
We know that the nand allocation of WM is like this, stepldr, eboot, MBR, OS... What is stored immediately after OS? FAT table? Or something else? The second question is, when is the FAT table in WM c...
szbeta Embedded System
[2008新書]Advanced FPGA Design Architecture, Implementation, and Optimization
Copyright # 2008 by John Wiley & Sons, Inc. All rights reserved. Published by John Wiley & Sons, Inc., Hoboken, New Jersey. Published simultaneously in Canada. No part of this publication may be repro...
koras FPGA/CPLD
The upper computer uses labview as the control panel, and the lower computer uses vxworks socket to communicate with the upper and lower computers.
The host computer uses labview as the client control panel, and the slave computer uses the socket of the vxworks operating system. How do they establish serial port communication?...
fujianfeng Real-time operating system RTOS
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as running...
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as an op amp circuit...
QWE4562009 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2671  527  2786  117  682  54  11  57  3  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号