EEWORLDEEWORLDEEWORLD

Part Number

Search

34ASP12T6M3RT

Description
Toggle Switch, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size979KB,6 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance
Download Datasheet Parametric View All

34ASP12T6M3RT Overview

Toggle Switch, ROHS COMPLIANT

34ASP12T6M3RT Parametric

Parameter NameAttribute value
Contact resistance0.01 mΩ
Maximum contact voltage (DC)20 V
Electrical life40000 Cycle(s)
End contact platingGOLD
Switch actionLATCHED
switch functionSPDT
Maximum contact current (DC)0.02 A
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
Is it Rohs certified?Yes
ECCN codeEAR99
Is SamacsysN
Objectid7002697747
package instructionROHS COMPLIANT
Reach Compliance CodeCompliant
sealEPOXY TERMINAL SEALED
Actuator materialBRASS
Shell materialSTAINLESS STEEL
insulator materialDIALLYL PHTHALATE
surface mountNO
Termination typeSOLDER
Center contact platingGOLD
End contact materialCOPPER ALLOY
illuminationNON-ILLUMINATED
Installation featuresTHROUGH HOLE-STRAIGHT
Executor completedCHROME
Casing diameter0.249 inch
Casing type1/4-40
center contact materialCOPPER ALLOY
contact timeMAKE-BEFORE-BREAK
body height0.415 mm
Body length or diameter0.65 mm
Nozzle length0.297 inch
Terminal length0.25 inch
Actuator length0.2 inch
body width0.5 mm
Actuator typeTOGGLE
Other featuresUL
Contact (DC) maximum rated R load5A@28VDC
Contact functionON-ON
Dielectric withstand voltage1000VRMS V
Insulation resistance1000000000 Ω
Contact (AC) maximum rated R load5A@125VAC
Maximum contact current (AC)0.02 A
Maximum contact voltage (AC)20 V
Switch typeTOGGLE SWITCH
Series 34A: Miniature Toggle Switches
Miniature Toggle Switches
FEATURES
• Save Space and Weight
• SPDT, DPDT, 3PDT, and 4DPT Circuitry
• Choice of Actuators, Bushings and Terminations
• UL Recognized
MODELS
SPDT
MODEL NO.
SP1
SP2
SP3
SP4
SP5
TERM. COMM.
SERIES 34A
in inches (and millimeters)
.570
(14.48)
SWITCH POSITION
ON
NONE
ON
NONE
ON
OFF
OFF
(ON)
OFF
ON
2-3,5-6
OPEN
8-9
Toggle Switches
KEYWAY
ON
(ON)
ON
(ON)
(ON)
2-1,5-4
8-7
.415
(10.54)
.030
(0.76)
KEYWAY
THIS SIDE
9
6
3
.500
(12.7)
.650
(16.51)
1/4-40 UNS-2A
.350
(8.89)
.410
(10.41)
.185
(4.70)
EPOXY SEAL
.060
(1.52)
.190
(4.83)
8
5
2
7
4
1
()=MOMENTARY
02COMM.
05COMM.
08COMM.
Ø.115
(Ø 2.92)
1
3
SCHEMATIC
4
6
7
9
DPDT
MODEL NO.
DP1
DP2
DP3
DP4
DP5
TERM. COMM.
SWITCH POSITION
NONE
ON
NONE
ON
OFF
ON
OFF
(ON)
OFF
ON
2-3,
OPEN
5-6
05COMM.
KEYWAY
ON
(ON)
ON
(ON)
(ON)
2-1,
5-4
.350
(8.89)
.410
(10.41)
.505
(12.83)
.060
(1.52)
KEYWAY
THIS SIDE
6
5
4
3
2
1
.190
(4.83)
.500
(12.7)
.450
(11.43)
1/4-40 UNS-2A
Ø.115
(Ø 2.92)
.185
(4.70)
()=MOMENTARY
02COMM.
.350
(8.89)
1
3 4
SCHEMATIC
6
.030
(0.76)
EPOXY SEAL
3PDT
MODEL NO.
SP1
SP2
SP3
SP4
SP5
TERM. COMM.
.570
(14.48)
SWITCH POSITION
ON
NONE
ON
NONE
ON
OFF
OFF
(ON)
OFF
ON
2-3,5-6
OPEN
8-9
KEYWAY
ON
(ON)
ON
(ON)
(ON)
2-1,5-4
8-7
.415
(10.54)
.030
(0.76)
KEYWAY
THIS SIDE
9
6
3
.500
(12.7)
.650
(16.51)
1/4-40 UNS-2A
.350
(8.89)
.410
(10.41)
.185
(4.70)
EPOXY SEAL
.060
(1.52)
.190
(4.83)
8
5
2
7
4
1
()=MOMENTARY
02COMM.
05COMM.
08COMM.
Ø.115
(Ø 2.92)
1
3 4
SCHEMATIC
6 7
9
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Are there any rules for setting the serial port baud rate? Why are they 2400, 9600, 19200...
[i=s]This post was last edited by shijizai on 2018-12-14 15:13[/i] Is there any rule for setting the serial port baud rate? Why are they 2400, 9600, 19200..., just like the baud rate required values i...
shijizai stm32/stm8
Does CC2650 support JLINK debugging? Here is the answer
[url]http://processors.wiki.ti.com/index.php/CC13xx_CC26xx_Tools_Overview#Segger_J-Link[/url]...
littleshrimp Wireless Connectivity
Circuit Simulation Software
[:D] It is relatively easy to use. Let's share our experiences. WorkbenchEWB simulation is very easy to use....
fighting Analog electronics
I don't understand the meaning of some keywords in the PICS file, and I would like to ask for advice
; ChangePrPaGrid function tranffering PLL2 information to PLL3. Generating past Grid ; voltage information ; LockDetect function writing on PLL4 and generating PLL5 status ; SoftStart function is gene...
yuke30 Microchip MCU
Why does this program run successfully on the emulator, but has no effect when burned to 89S52? Thanks in advance!
The function is two timers , T0 controls P10 and T1 controls P17, which turn on and off respectively. The following program can see the effect on the emulator, but when burned into the AT89S52, it doe...
urcllr 51mcu
Launchpad serial port problem
Recently when I was learning about Launchpad, I encountered this problem: Is it impossible to achieve serial communication by connecting USB and PC? Using the same procedure, I connected RXD and TXD t...
zzzvvvxxxd Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2801  932  1295  2503  2815  57  19  27  51  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号