EEWORLDEEWORLDEEWORLD

Part Number

Search

MA-S20ASC3

Description
磁性 磁簧开关 磁体 NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size609KB,6 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MA-S20ASC3 Overview

磁性 磁簧开关 磁体 NC 电缆引线 盒

MA-S20ASC3 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMA-STI
PackageBulk
type磁簧开关
Output typeNC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply230VAC
must work-
must be released-
Operating temperature-10°C ~ 95°C(TA)
Package/casingbox
Basic product numberMA-S20
Safety Interlock Switches
MA-S Series
Stainless Steel Magnetically Actuated
Safety Interlock Switches and Actuators
• Stainless steel cases—both switch and actuator are housed in stainless steel
for applications that require the use of this robust and corrosion resistant
material
• Large selection—choose from a variety of contact configurations housed in
stainless steel to satisfy the most demanding applications
• NEMA 6 enclosure enables the MA-S Series switches to satisfy most applica-
tion requirements
• Misalignment tolerant—the non-contact actuation of the MA-S Series switches
makes them very tolerant to misalignment of up to 10 mm (0.39 in.)
• High temperature—the MA-S switches and cables are designed to operate in
temperatures up to 125°C (257°F)
• Long life—the MA-S Series safety interlock switches are designed for a
minimum of one million actuations
• A Rapid Delivery Product: Select models are available for shipment today or
within 3 to 5 days
R
C
US
Specifications
Electrical
Safety Contacts:
Conforms to EN1088, EN292, EN60204-1
UL and C-UL listed
G
All Models Unless Indicated
AC models
DC models
MA-S2, S21, 34, 35, 36
MA-S2, S21, 34, 35,S36
AC models
DC models
AC models
DC models: All except MA-35
DC model: MA-35
AC models
DC models: All except MA-35
AC models
DC models
Safety Contact Operating Distance:
Auxiliary Contacts:
Aux. Contact Operating Distance:
Safety Rated Voltage:
Safety Rated Current:
Internal Fuse
External Fuse (Customer Supplied)
Electrical Life:
Mechanical—Special Safety Reed
Closing Time:
Drop-Out Time:
Bounce Time:
Shock:
Vibration:
Mechanical
Mounting:
Case & Actuator Material:
Wiring Connection:
Weight:
Color:
Mechanical Life:
Environmental
Protection:
Operating Temperature:
MA-S2, 36 — 1 N/C
MA-S20, S21 — 2 N/C
MA-S2, 34, 36 — 1 N/C
MA-S20, S21, 35, 36 — 2 N/C
Make 7-12 mm (0.28-0.47 in.); Break 12-25 mm (0.47 to 0.98 in.)
1 N/O
Make 10-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.)
230 VAC
30 VDC
2 A max., fuse externally 1.6 A quick acting
1 A, fuse externally 800 mA quick acting
0.3 A max., fuse externally 0.2 A quick acting
2 A fast acting
1 A fast acting
1.6 A fast acting
0.8 A fast acting
1 x 10
6
Safety.
Aux.
3.0 mS
0.5 mS
2.1 mS
0.3 mS
0.7 mS
0.7 mS
10 G
10 G
10 G, 50 to 100 Hz
Any position
Stainless steel
Various lengths or male M12 micro connector
600 g (1 lb. 5 oz.)
Stainless steel
10 x 10
6
IP67 (NEMA 6)
-10 to 95°C (14 to 203°F); Connector Models: -10 to 55°C (14 to 131°F)
-10 to 55°C (14 to 131°F)
-10 to 125°C (14 to 257°F)
-20 to 70°C (-4 to 158°F)
MA-S2, S20, S21
MA-34, 35, 36
MA-35HT
EN1088, EN292, EN60204-1
CE marked for all applicable directives
MA-S2, S20, S21
UL and C-UL
MA-34, 35, 36
UL and C-UL
Reliability Data
per EN ISO 13849-1: – B10d: 2.00E+06
Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the
guard closed, actuator in place, and the machine able to be started.
Storage Temperature
Compliance
Standards:
Approvals/Listings:
www.omron247.com
G-103
The same BSP, but my computer can't generate eboot.nb0
As the title says, two people in the company develop drivers. We use the same BSP. His computer can generate eboot.nb0 but mine can't. I compared all the files and PB configurations, and they are all ...
skdarkness Embedded System
Msp430 Flash was accidentally erased
Under what circumstances will the MSP430 Flash be accidentally erased? Recently, after downloading the program through FET, I tested it and it worked fine. After a while, I tested it again and found t...
Num_jry Microcontroller MCU
How to choose the power chip of DSP? How to use software?
The development of ultra-large-scale integrated circuits has evolved from 1um to the current 0.1um, and the power supply voltage of the chip has also decreased, and the power consumption has also decr...
火辣西米秀 DSP and ARM Processors
Keil5 compilation error
Load "E:\\keil\\shiyan\\Boards\\ST\\NUCLEO-L053R8\\RTX_Blinky\\Flash\\RTX_Blinky.axf"_____^ *** error 56: cannot open file Error: Flash Download failed-Could not load file 'E:\keil\shiyan\Boards\ST\NU...
ddd4 stm32/stm8
Get the information of WCS2720
A current detection module. Here is the link to Taobao first. I don't want to buy his products, but I want to know its principle. Who has complete information? Can you give me a copy? I don't know if ...
ywlzh MCU
Could you please help me figure out what manufacturer's logo this is?
Thank you so much...
yshmily Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 696  1524  1267  2163  1500  14  31  26  44  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号