MA16DP20C6

Description
磁性 磁簧开关 磁体 NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size844KB,8 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MA16DP20C6 Overview

磁性 磁簧开关 磁体 NC 电缆引线 盒

MA16DP20C6 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMA-STI
PackageBulk
type磁簧开关
Output typeNC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply230VAC
must work-
must be released-
Operating temperature-10°C ~ 55°C(TA)
Package/casingbox
Basic product numberMA-16DP
Safety Interlock Switches
MA Series
Magnetically Actuated
Safety Interlock Switches
• Large selection—choose from a large selection of contact configurations
housed in plastic to satisfy most application requirements
• NEMA 6 enclosure enables the MA Series switches to satisfy most
application requirements (MA 3, 4, 5 are NEMA 4)
• Misalignment tolerant—the non-contact actuation of the switches makes
them very tolerant to misalignment of up to 10 mm (0.39 in.)
• Variety of terminations—select various cable lengths or terminal strip
termination for easy installation. Cable connector on selected models.
• Long life—the MA Series is designed for a minimum of one million actuations
• A Rapid Delivery Product: Select models are available for shipment today or within 3 to 5 days
R
C
US
Specifications
Electrical
Safety Contacts:
Safety Contact Operating Distance:
Auxiliary Contacts:
All Models Unless Indicated
AC models
DC models
Conforms to EN1088, EN292, EN60204-1
UL and C-UL listed
MA-2, 4, 12, 13, 14, 15, 16, 21
MA-3
Aux. Contact Operating Distance:
MA-2, 4, 16, 21
MA-3
Safety Rated Voltage:
AC models: All except MA-10
AC models: MA-10
DC models
Safety Rated Current:
AC models: All except MA-3
AC model: MA-3
DC models: All except MA-15
DC model: MA-15
Internal Fuse:
AC models
DC models
External Fuse (Customer Supplied): AC models
DC models: All except MA-15
Electrical Life:
Mechanical—Special Safety Reed
Closing Time:
Drop-Out Time:
Bounce Time:
Shock:
Vibration:
Mechanical
Mounting:
Any position
Case & Actuator Material:
Molded ABS
Wiring Connection:
Various lengths or male M12 micro connector
Weight:
Approx. 384 g (14 oz.)
Color:
Red
Mechanical Life:
10 x 10
6
Environmental
Protection:
All models except MA-3, 4, 5
IP67 (NEMA 6)
MA-3, 4, 5
IP65 (NEMA 4)
Operating Temperature:
All models except MA-3, 4, 5
-10 to 55°C (14 to 131°F)
MA-3, 4, 5
-10 to 65°C (14 to 149°F)
Compliance
Standards:
EN1088, EN292, EN60204-1
Approvals/Listings:
CE marked for all applicable directives
All models: except MA-3, 4, 5
UL and C-UL
MA-3, 4, 5
cCSAus
Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the
guard closed, actuator in place, and the machine able to be started.
MA-1 thru 5, 10, 12, 13, 16 — 1 N/C
MA-13, 16, 21 — 2 N/C
MA-12, 13, 14, 16 — 1 N/C
MA-13, 15, 16, 20, 21 — 2 N/C
Make 7-12 mm (0.28-0.47in.); Break 12-25 mm (0.47-0.98 in.)
1 N/O
1 N/C
Make 8-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.)
Make 21 mm (0.83 in.); Break 24 mm (0.94 in.)
230 VAC
110 VAC
30 VDC
2 A, fuse externally 1.6 A quick acting
3 A, fuse externally 2.5 A quick acting
1 A, fuse externally 800 mA quick acting
0.3 A max., fuse externally 0.2 A quick acting
2 A fast acting
1 A fast acting
1.6 A fast acting
0.8 A fast acting
1 x 10
6
Safety
Aux.
3.0 mS
0.5 mS
2.1 mS
0.3 mS
0.7 mS
0.7 mS
10 G
10 G
10 G, 50 to 100 Hz
G
www.sti.com/info
G-97
The most ridiculous joke in history (I will live by this joke in my life)
In order to liven up the atmosphere, everyone took out their own treasures and relaxed in the busy work! [color=red]This joke is what I live for in this life! [/color] [size=6][color=blue][b]Say[/b][/...
小娜 Talking
Motor inductance problem
According to the Ampere loop theorem of the entire circuit, the current direction of all the wires in the single-phase winding coil of the motor is the same, and the magnetic field strength H generate...
bigbat Motor Drive Control(Motor Control)
I especially want to know that some high-frequency transformers have two intermediate taps.
[backcolor=rgb(239, 245, 249)][size=14px]I would like to know where the high-frequency transformers have two intermediate taps. Where do these two taps come from? What are they used for? How are they ...
chuzhaonan LED Zone
Automatic reload value for serial communication
TH1 = TL1 = 256 - Crystal value/12 /2/16 /Baud rate What does the last part mean? Why should it be written like this?...
dongdong0071 51mcu
25 yuan a piece low price to process the new digital infrared sensor MLX90615SSG-DAG with LCD and routine program
The MLX90615 is an infrared thermometer for non-contact temperature measurement. The IR sensitive thermopile detector chip and the signal processing ASSP are integrated in the same TO-46 sealed can pa...
lishuchang1981 Buy&Sell
I just finished making a DIY visual placement machine
[i=s]This post was last edited by net2uizoo on 2014-11-28 16:49[/i]I have just finished making a DIY visual placement machine, with an effective placement range of about 200mmx450mm, double heads, and...
net2uizoo Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2623  1045  546  1622  2398  53  22  11  33  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号