Operating/Storage: 35% to 95% (with no condensation)
±10%
max. of sensing distance at 23°C in the temperature range of
−25
to 70°C
±2.5%
max. of sensing distance at rated voltage in the rated voltage
±15%
range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
2
3 times each in X, Y, and Z directions
IEC 60529 IP67, in-house standards: oil-resistant
*2
Pre-wired Models (Standard cable length: 2 m)
Approx. 45 g
Heat-resistant ABS
Instruction manual
*1. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
2
TL-W
DC 3-Wire Models
Model
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing
object
Response
frequency
TL-W1R5MC1
1.5 mm
±10%
0 to 1.2 mm
TL-W3MC@
3 mm
±10%
0 to 2.4 mm
TL-W5MC@
5 mm
±10%
0 to 4 mm
TL-W5E1, TL-W5E2
TL-W5F1, TL-W5F2
TL-W20ME1
TL-W20ME2
20 mm
±10%
0 to 16 mm
1% to 15% of
sensing distance
Iron, 50
×
50
×
1 mm
300 Hz min.
12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 20% max.
15 mA max. at 24 VDC (no-load)
40 Hz min.
12 to 24 VDC (10
to 30 VDC), ripple
(p-p): 10% max.
8 mA at 12 VDC,
15 mA at 24 VDC
100 mA max. at
12 VDC
200 mA max. at
24 VDC
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to
Engineering Data
on page 5.)
Iron, 8
×
8
×
1 mm
1 kHz min.
Iron, 12
×
12
×
1 mm Iron, 18
×
18
×
1 mm
600 Hz min.
500 Hz min.
Power supply volt-
age (operating volt-
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
age range)
Current
consumption
15 mA max. at 24 VDC (no-load)
10 mA max.
NPN open collector
50 mA max. at
12 VDC (30 VDC
max.)
100 mA max. at
24 VDC (30 VDC
max.)
Load
current
Control
output
NPN open collector
100 mA max. at 30 VDC max.
200 mA
Residual
1 V max. (under load current of 100 mA with
voltage
cable length of 2 m)
Indicators
Operation mode
(with sensing ob-
ject approaching)
Protection circuits
Ambient
temperature range
Ambient
humidity range
Temperature
influence
Voltage influence
Insulation
resistance
Dielectric strength
Vibration
resistance
Detection indicator (red)
NO
C1 Models: NO
C2/B2 Models: NC
1 V max. (under
1 V max. (under load
2 V max. (under load current of load current of
current of 50 mA with
200 mA with cable length of 2 m) 200 mA with ca-
cable length of 2 m)
ble length of 2 m)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under
I/O Circuit Diagrams
on page 6 for details.
Reverse polarity protection, Surge suppressor
Operating/Storage:
−25
to 70°C (with no icing or condensation)
*
Operating/Storage: 35% to 95% (with no condensation)
±10%
max. of sensing distance at 23°C in the temperature range of
−25
to 70°C
±2.5%
max. of sens-
±2.5%
max. of sensing distance at rated volt- ing distance at rated
age in the rated voltage
±10%
range
voltage in the rated
voltage
±20%
range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction:
500 m/s
2
10
times each in X,
Y, and Z direc-
tions
±2.5%
max. of sensing distance at rated voltage in
the rated voltage
±10%
range
Shock resistance
Destruction: 500 m/s
2
3 times each in X, Y, and Z directions
Degree of
protection
Connection
method
Weight
(packed state)
Materi-
als
Case
Sensing
surface
IEC 60529 IP67, in-house standards: oil-resistant
*
Pre-wired Models (Standard cable length: 2 m)
Approx. 30 g
Heat-resistant ABS
Heat-resistant ABS
Mounting Bracket, Instruction manual
Instruction manual
Approx. 45 g
Approx. 70 g
Aluminum die-cast
Approx. 180 g
Heat-resistant
ABS
Accessories
* For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
[align=center]This event is the same live broadcast as Fujitsu's "[url=https://www.eeworld.com.cn/huodong/Fujitsu_FRAM3D_20190523/index.html?sid=101]Talk about Automotive Grade FRAM and German Quality...
The MPLAB? ICD 2 module is a low-cost development tool that connects a PC to a design target board, allowing designers to directly debug the target PIC? microcontroller or dsPIC? DSC online. This modu...
The following is some of my understanding of the microcontroller reset circuit: 1. Why does the microcontroller need to be reset? To restore the microcontroller to its initial state, and start execu...
I recently used a wince machine for development. During the development process, I found that each time I saved about 800 bytes of data to a file, the speed slowed down after saving about 100, and inc...
Microcontrollers (MCUs), which are widely used in automotive electronics, are rapidly facing time and cost pressures. The main advantage of using MCUs has always been to create high-level system in...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
With the continuous improvement of the requirements of intelligent building security systems and the continuous improvement of people's safety awareness, indoor anti-theft has gradually attracted peop...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
At very low temperatures, certain metals and alloys lose their resistance to electric
current
and become
superconductors
. Two parameters that are often measured are the transition ...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
LED technology has made rapid progress, and improvements in chip design and materials have promoted the development of brighter and more durable light sources, and the scope of light source applica...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
One in five car failures are caused by batteries, a problem that will become more serious in the coming years as electric-by-wire, start/stop engine management and hybrid (electric/gas) vehicles be...[Details]