EEWORLDEEWORLDEEWORLD

Part Number

Search

MA-34DS10C10

Description
磁性 磁簧开关 磁体 NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size609KB,6 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MA-34DS10C10 Overview

磁性 磁簧开关 磁体 NC 电缆引线 盒

MA-34DS10C10 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMA-STI
PackageBulk
type磁簧开关
Output typeNC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply230VAC
must work-
must be released-
Operating temperature-10°C ~ 55°C(TA)
Package/casingbox
Basic product numberMA-34DS
Safety Interlock Switches
MA-S Series
Stainless Steel Magnetically Actuated
Safety Interlock Switches and Actuators
• Stainless steel cases—both switch and actuator are housed in stainless steel
for applications that require the use of this robust and corrosion resistant
material
• Large selection—choose from a variety of contact configurations housed in
stainless steel to satisfy the most demanding applications
• NEMA 6 enclosure enables the MA-S Series switches to satisfy most applica-
tion requirements
• Misalignment tolerant—the non-contact actuation of the MA-S Series switches
makes them very tolerant to misalignment of up to 10 mm (0.39 in.)
• High temperature—the MA-S switches and cables are designed to operate in
temperatures up to 125°C (257°F)
• Long life—the MA-S Series safety interlock switches are designed for a
minimum of one million actuations
• A Rapid Delivery Product: Select models are available for shipment today or
within 3 to 5 days
R
C
US
Specifications
Electrical
Safety Contacts:
Conforms to EN1088, EN292, EN60204-1
UL and C-UL listed
G
All Models Unless Indicated
AC models
DC models
MA-S2, S21, 34, 35, 36
MA-S2, S21, 34, 35,S36
AC models
DC models
AC models
DC models: All except MA-35
DC model: MA-35
AC models
DC models: All except MA-35
AC models
DC models
Safety Contact Operating Distance:
Auxiliary Contacts:
Aux. Contact Operating Distance:
Safety Rated Voltage:
Safety Rated Current:
Internal Fuse
External Fuse (Customer Supplied)
Electrical Life:
Mechanical—Special Safety Reed
Closing Time:
Drop-Out Time:
Bounce Time:
Shock:
Vibration:
Mechanical
Mounting:
Case & Actuator Material:
Wiring Connection:
Weight:
Color:
Mechanical Life:
Environmental
Protection:
Operating Temperature:
MA-S2, 36 — 1 N/C
MA-S20, S21 — 2 N/C
MA-S2, 34, 36 — 1 N/C
MA-S20, S21, 35, 36 — 2 N/C
Make 7-12 mm (0.28-0.47 in.); Break 12-25 mm (0.47 to 0.98 in.)
1 N/O
Make 10-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.)
230 VAC
30 VDC
2 A max., fuse externally 1.6 A quick acting
1 A, fuse externally 800 mA quick acting
0.3 A max., fuse externally 0.2 A quick acting
2 A fast acting
1 A fast acting
1.6 A fast acting
0.8 A fast acting
1 x 10
6
Safety.
Aux.
3.0 mS
0.5 mS
2.1 mS
0.3 mS
0.7 mS
0.7 mS
10 G
10 G
10 G, 50 to 100 Hz
Any position
Stainless steel
Various lengths or male M12 micro connector
600 g (1 lb. 5 oz.)
Stainless steel
10 x 10
6
IP67 (NEMA 6)
-10 to 95°C (14 to 203°F); Connector Models: -10 to 55°C (14 to 131°F)
-10 to 55°C (14 to 131°F)
-10 to 125°C (14 to 257°F)
-20 to 70°C (-4 to 158°F)
MA-S2, S20, S21
MA-34, 35, 36
MA-35HT
EN1088, EN292, EN60204-1
CE marked for all applicable directives
MA-S2, S20, S21
UL and C-UL
MA-34, 35, 36
UL and C-UL
Reliability Data
per EN ISO 13849-1: – B10d: 2.00E+06
Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the
guard closed, actuator in place, and the machine able to be started.
Storage Temperature
Compliance
Standards:
Approvals/Listings:
www.omron247.com
G-103
Have you found the difference between F28027 and F28027F?
I bought the Launchxl-F28027 board at a low price on Xianyu. It had been idle for a few months because I was using C2000 for wireless. Recently, I wanted to use FOC technology. I looked up information...
watershade Microcontroller MCU
Research on TinyOS in Wireless Sensor Networks
Abstract: Wireless sensor networks are a new information acquisition and processing technology that can monitor, sense and collect information from various environments or monitored objects in real ti...
吸铁石上 RF/Wirelessly
Design of NAND FLASH Driver Based on VxWorks
[b]0 Introduction[/b] At present, with the continuous development of electronic technology, computer technology has also developed rapidly, and many new technologies have emerged. However, in terms of...
yuandayuan6999 MCU
Ask about the example of CUDP_CE in evc advanced programming
In the CUDP_CE example in evc advanced programming, sending data is fine, but receiving data cannot be received. I wonder if anyone has used this example and knows the reason. If you have other UDP co...
wchq1 Embedded System
Problems using MPLAB XIDE
In MPLAB X IDE, can't a switch statement use a variable after a case? switch(Displacement[5]) { case Displacement[0]: Run_Section = 0; // break in acceleration section; Like above, the error is as fol...
asdmaill Microchip MCU
How to suppress common impedance in advanced PCB design?
In order to suppress the common impedance interference of PCB design, the following measures can be adopted: (1) Single-point grounding Make the grounding points of the same-level unit circuits as con...
ESD技术咨询 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1991  1555  330  166  901  41  32  7  4  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号