switch functionOn-momentary
Rated current (amps)1A(DC)
Actuator typespring, pole
Installation typeBase installation
Termination styleConnector
Intrusion protectionIP67 - dust and water resistant
characteristic-
Operating force150gf
release force-
Pre-trip15°
Differential travel-
Overtravel-
Operating temperature-10°C ~ 70°C
work location-
Electrical life200,000 cycles
Mechanical life10,000,000 cycles
Rated voltage - DC30 V
Basic product numberD4C
Miniature Limit Switch
D4CC
Many Models Including Roller Lever
Switches are Only 16-mm Thick with
Connector
• New center roller lever models that enable ganged mounting of
up to 6 Switches.
• Cable connectors for easy Switch replacement.
• Triple-seal construction for plungers to provide IEC IP67, UL,
and CSA (type 3, 4, 13) degree of protection.
• Operation indicators available for easy monitoring (standard in-
dicator is lit when Switch is not operating).
Model Number Structure
Model Number Legend
D4CC-@0@@
1
1. Rated Load
(These codes are different from suffix codes of the D4C)
1:
2:
3:
4:
1 A at 125 VAC
1 A at 125 VAC (with LED indicator)
1 A at 30 VDC
1 A at 30 VDC (with LED indicator)
2
2. Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
10: Bevel plunger
24: Roller lever
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller plunger
41: Panel mount pin plunger
42: Panel mount roller plunger
43: Panel mount crossroller plunger
50: Plastic rod
60: Center roller lever
Note:
With standard models, the operation indicator turns OFF when
the switch operates. If models with operation indicators that
turn ON when the switch operates are required, add "-B” to the
end of the model number.
Miniature Limit Switch
D4CC
1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 627  2558  2761  2668  1004  13  52  56  54  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号