EEWORLDEEWORLDEEWORLD

Part Number

Search

H5CX-A-N AC100-240

Description
可编程(多功能) 延时继电器 SPDT(1 Form C) 0.001 秒 ~ 9999 小时 延时 5A @ 250VAC 面板安装
CategoryMechanical and electronic products    Time delay and timing relay   
File Size7MB,44 Pages
ManufacturerOmron Automation and Safety
Environmental Compliance
Download Datasheet Parametric View All

H5CX-A-N AC100-240 Overview

可编程(多功能) 延时继电器 SPDT(1 Form C) 0.001 秒 ~ 9999 小时 延时 5A @ 250VAC 面板安装

H5CX-A-N AC100-240 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesH5CX
Packagebox
Installation typePanel mounting
Relay typeMechanical relay
FunctionProgrammable (multi-function)
circuitSPDT(1 Form C)
delay0.001 seconds ~ 9999 hours
Rated contact current at different voltages5A @ 250VAC
Voltage - Power supply100 ~ 240VAC
Termination stylescrew terminal
Timing adjustment methodUp/Down numeric keys
Timed start methodinput voltage, trigger signal
Basic product numberH5CX-A
Digital Timer
H5CX-@-N
Ultra-compact Timer Provides Advanced
Functions and Security Settings.
Basic Features
• Short body with depth of only 59 mm (for 24-VAC / 12 to 24-VDC Models with
Screw Terminals).
*1
• Character height of 12 mm for better readability (on models with 4 digits).
• The present value display characters can be switched between red, green,
and orange.
*2
Safety and Reliability
• Power supply circuit and input circuits are isolated for safety and reliability.
*3
• New set value limit and output counter functions have been added.
*4
Other Features
• Front Panel can be changed to white or light gray.
*5
• Models with instantaneous contact output added to the series.
*1.
For 100 to 240 VAC Models with Screw Terminals 78 mm, Models with Sockets: 63.7 mm
(case dimension).
*2.
The H5CX-A11, H5CX-L8 and H5CX-B Timers have only red characters.
*3.
Specifications: 100 to 240 VAC
*4.
The value of the output counter can only be monitored. It cannot be reset.
*5.
Replacement Front Panels sold separately.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to “Safety
Precautions”
on
page 41.
Features
Basic Features
Ultra Short Body
The body depth has been greatly reduced. Helps in making thinner
control panels. (Models with Screw Terminals)
24-VAC / 12 to 24-VDC Models with Screw Terminals: 59 mm
100 to 240-VAC / VDC Models with Screw Terminals: 78 mm
*
Models with Sockets: 63.7 mm (case dimension)
*
The shortest body for a timer with isolated power supply and input circuits and a maximum
ambient temperature of 55°C (according to OMRON investigation in June 2009).
Safety and Reliability
Isolated Power Supply and Input Circuits
*1
Power supply circuit and input circuits are isolated for safety and
reliability.
Previous non-isolated timers had wiring restrictions and could be damaged if
wired incorrectly. The New H5CX removes these worries.
Previous
H5CX
AC power
supply
*2
Output terminal on PLC
or other device
Input terminal
0-V terminal
COM terminal
–V
+V
Forget These
Worries with the
New H5CX
New models
Previous
models
Stabilized DC
power supply
*2.
The AC power supply ground is on the commercial power supply side.
Easier to Read
For better readability, the character height for the present value display
is 12 mm (on models with 4 digits), the largest class in the industry. The
wide viewing angle and brightness provide excellent visibility.
The number of display segments has also been increased to make settings
easier to understand, and the present value display can be switched between
red, green and orange so that output status can be seen from a distance.
*1.
New Models (H5CX-@-N) with 100 to 240-VAC specifications.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Model with 4 Digits Model with 6 Digits
12 mm
(actual size)
10 mm
(actual size)
Worry-free operation
is achieved with the
New H5CX by
restricting the time
that can be set.
(Display example)
Note:
The H5CX-A11 and H5CX-L8 Timers have only red characters.
Output Counter
An output counter counts the number of times that the output turns
ON. (An alarm can be set and the value of the output counter can be
monitored, Unit: 1,000 operations.) This counter is useful in managing
the service life of the Timrrer or the load.
The Easiest Operation
Operation is simplified by the
Up/Down Keys for each digit
on 4-digit models and Up Keys
for each digit on 6-digit
models.
Model with 4 Digits
Model with 6 Digits
1
An exciting wifi chip
[i=s]This post was last edited by wateras1 on 2015-4-18 14:07[/i] Recently, I came across a very cost-effective wifi chip for work, and I introduced it to everyone in the forum: ESP8266. I won't say m...
wateras1 RF/Wirelessly
Is there any good input method or provider?
Everyone knows that the input method on WINCE is not very easy to use. Now I want to find a better input method. I wonder if anyone has provided one. It is also OK if there is a provider. It requires ...
opcpwm Embedded System
The role of negative pressure in LCD screens
In daily work, we occasionally encounter customer feedback: the LCD screen does not display or displays very light after it is turned on. The impact of voltage on this problem is often ignored by us. ...
罗姆液晶技术站 Integrated technical exchanges
Jiangsu Haimen City - Haimen Shouwei Electronics Co., Ltd. - Recruitment of simulation layout/design
[table=98%] [tr][td][b]We sincerely recruit talents from the society. Welcome to send your resume or call us for inquiries. Thank you! [/b] Company name: Haimen Archer Electronics Co., Ltd. Workplace:...
mixinno Recruitment
A letter from a leader to his employees: a typical leader born in the 70s and an employee born in the 80s
I want to say to the marketing department: Please be happy to accept the work at hand, don't say no. In fact, I can understand your mood and situation. In fact, the current situation you are in is the...
向农 Talking about work
What you need to know about network engineering (Part 1)
The setting of IP address and subnet mask is the basic network knowledge that every network administrator must have. Only by understanding the true meaning of IP address and subnet mask can we manage ...
wangluochuxue RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1117  2407  2563  2910  760  23  49  52  59  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号