EEWORLDEEWORLDEEWORLD

Part Number

Search

MA-21DPC6

Description
磁性 磁簧开关 磁体 NO/NC 电缆引线 盒
CategoryThe sensor    MagneticSensor   
File Size844KB,8 Pages
ManufacturerOmron Automation and Safety
Download Datasheet Parametric View All

MA-21DPC6 Overview

磁性 磁簧开关 磁体 NO/NC 电缆引线 盒

MA-21DPC6 Parametric

Parameter NameAttribute value
category
MakerOmron Automation and Safety
seriesMA-STI
PackageBulk
type磁簧开关
Output typeNO/NC
Actuator materialmagnet
Termination styleCable leads
Voltage - Power supply230VAC
must work-
must be released-
Operating temperature-10°C ~ 55°C(TA)
Package/casingbox
Basic product numberMA-21
Safety Interlock Switches
MA Series
Magnetically Actuated
Safety Interlock Switches
• Large selection—choose from a large selection of contact configurations
housed in plastic to satisfy most application requirements
• NEMA 6 enclosure enables the MA Series switches to satisfy most
application requirements (MA 3, 4, 5 are NEMA 4)
• Misalignment tolerant—the non-contact actuation of the switches makes
them very tolerant to misalignment of up to 10 mm (0.39 in.)
• Variety of terminations—select various cable lengths or terminal strip
termination for easy installation. Cable connector on selected models.
• Long life—the MA Series is designed for a minimum of one million actuations
• A Rapid Delivery Product: Select models are available for shipment today or within 3 to 5 days
R
C
US
Specifications
Electrical
Safety Contacts:
Safety Contact Operating Distance:
Auxiliary Contacts:
All Models Unless Indicated
AC models
DC models
Conforms to EN1088, EN292, EN60204-1
UL and C-UL listed
MA-2, 4, 12, 13, 14, 15, 16, 21
MA-3
Aux. Contact Operating Distance:
MA-2, 4, 16, 21
MA-3
Safety Rated Voltage:
AC models: All except MA-10
AC models: MA-10
DC models
Safety Rated Current:
AC models: All except MA-3
AC model: MA-3
DC models: All except MA-15
DC model: MA-15
Internal Fuse:
AC models
DC models
External Fuse (Customer Supplied): AC models
DC models: All except MA-15
Electrical Life:
Mechanical—Special Safety Reed
Closing Time:
Drop-Out Time:
Bounce Time:
Shock:
Vibration:
Mechanical
Mounting:
Any position
Case & Actuator Material:
Molded ABS
Wiring Connection:
Various lengths or male M12 micro connector
Weight:
Approx. 384 g (14 oz.)
Color:
Red
Mechanical Life:
10 x 10
6
Environmental
Protection:
All models except MA-3, 4, 5
IP67 (NEMA 6)
MA-3, 4, 5
IP65 (NEMA 4)
Operating Temperature:
All models except MA-3, 4, 5
-10 to 55°C (14 to 131°F)
MA-3, 4, 5
-10 to 65°C (14 to 149°F)
Compliance
Standards:
EN1088, EN292, EN60204-1
Approvals/Listings:
CE marked for all applicable directives
All models: except MA-3, 4, 5
UL and C-UL
MA-3, 4, 5
cCSAus
Specifications are subject to change without notice. Note: The safety contacts of the STI switches are described as normally closed (N/C) i.e., with the
guard closed, actuator in place, and the machine able to be started.
MA-1 thru 5, 10, 12, 13, 16 — 1 N/C
MA-13, 16, 21 — 2 N/C
MA-12, 13, 14, 16 — 1 N/C
MA-13, 15, 16, 20, 21 — 2 N/C
Make 7-12 mm (0.28-0.47in.); Break 12-25 mm (0.47-0.98 in.)
1 N/O
1 N/C
Make 8-13 mm (0.39-0.51 in.); Break 8-10 mm (0.31-0.39 in.)
Make 21 mm (0.83 in.); Break 24 mm (0.94 in.)
230 VAC
110 VAC
30 VDC
2 A, fuse externally 1.6 A quick acting
3 A, fuse externally 2.5 A quick acting
1 A, fuse externally 800 mA quick acting
0.3 A max., fuse externally 0.2 A quick acting
2 A fast acting
1 A fast acting
1.6 A fast acting
0.8 A fast acting
1 x 10
6
Safety
Aux.
3.0 mS
0.5 mS
2.1 mS
0.3 mS
0.7 mS
0.7 mS
10 G
10 G
10 G, 50 to 100 Hz
G
www.sti.com/info
G-97
RTL buffer insertion and fault classification techniques that facilitate verification of untested functionality
At present, the design cycle of integrated circuits is required to be shorter, but the scale is larger and the structure is more complex. Improving the test coverage of chips has become one of the foc...
lhy FPGA/CPLD
printf has an impact on serial communication
I made a serial communication program under Linux and found a strange phenomenon. We used serial port 0 for communication, so we have turned off the option of serial port 0 as a control terminal - tha...
辛昕 Linux and Android
One PCI driver for multiple identical devices
I have multiple identical PCI devices plugged into the same host, but only one device functions normally. Can you tell me how to modify the driver so that it can drive multiple identical devices? I ho...
过云雨 Embedded System
HGI M0+ low power MCU RTC module example
[align=left][font=Calibri][color=#000000]/************************************************************/[/color][/font][/align] [align=left][color=#000000][font=Calibri]/******* [/font]Sample Usage Ins...
deepskin1213 MCU
Apply for LM3S811 to make a line-finding car
I don’t know if I can still apply for it!...
蓝雨夜 Microcontroller MCU
Agriculture in Germany
[i=s]This post was last edited by wangfuchong on 2014-2-3 11:42[/i] Some time ago, I saw someone on a website talking about Germany saying that Germany doesn’t grow crops, but grass, because Germany h...
wangfuchong Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1157  1741  1655  2569  2700  24  36  34  52  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号