EEWORLDEEWORLDEEWORLD

Part Number

Search

55.33.8.230.2000

Description
Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.33.8.230.2000 Overview

Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output

55.33.8.230.2000 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height37.2 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)184 V
Coil resistance17000 Ω
Maximum coil voltage (AC)253 V
Nominal coil voltage230 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER CADMIUM OXIDE
Number of terminals11
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
physical size27.7mm x 20.7mm x 37.2mm
Relay actionMBB
Relay style3 FORM C
Relay function3PDT-CO
release time5 ms
Terminal length0.0056 inch
Termination typeQUICK CONNECT
Base Number Matches1
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Need more bandwidth in Ka-band?
As the demand for global connectivity grows, many satellite communication (satcom) systems are increasingly using Ka-band frequencies, and the requirements for data rates are also rising. Currently, h...
btty038 RF/Wirelessly
(Serial 10) Calculation of energy storage inductance of parallel switching power supply
[p=null, 2, left][color=rgb(62, 62, 62)][font="][size=16px][b]1-4-3. Calculation of energy storage inductance of parallel switching power supply[/b][/size][/font][/color][/p][p=null, 2, left][color=rg...
木犯001号 Power technology
Basic knowledge of variable frequency constant pressure water supply
1. Features of variable frequency constant pressure water supply 1. Energy saving, can achieve 20%-40% electricity saving, can achieve green electricity use. 2. Small footprint, low investment, high e...
eeleader-mcu Industrial Control Electronics
Wind turbine charging control
400W wind turbine, need to make a rectifier, charging circuit, the battery is 24V100AH, please help!...
kacanmmx Embedded System
Rewrite data in the nor flash that already has data
Write data again in the nor flash which already has data, and only write data in part of it. It would be best if you give an example!!!...
kwyxp Embedded System
How to handle reserved IP when udhcpd allocates IP
I use udhcpd as a server to assign IP addresses. How does udhcpd handle reserved addresses? Is it written into udhcpd.leases? If so, in what format? If not, how should it be handled?...
xwinter123 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 506  1165  492  1644  1434  11  24  10  34  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号