low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
-20...90
100
10
85
Number of digital outputs: 2; Number of analogue outputs: 1
threaded connection G 1/2
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA2000-00 — 28.07.2021 —
SA2000
Flow sensor
SAR12XDBFRKG/US-100
Electrical data
Operating voltage
Current consumption
Protection class
Reverse polarity protection
Power-on delay time
Inputs / outputs
Number of inputs and outputs
Outputs
Total number of outputs
Output signal
Electrical design
Number of digital outputs
Output function
Max. voltage drop switching
output DC
Permanent current rating of
switching output DC
Number of analogue outputs
Analogue current output
Max. load
Short-circuit protection
Type of short-circuit
protection
Overload protection
Frequency of the output
Measuring/setting range
Probe length L
Operating mode
Note on factory setting
Temperature monitoring
Measuring range
Resolution
[°C]
[°C]
-20...90
0.2
[mm]
19.2
relative; absolutely liquid; absolutely gaseous;
(absolute: reference measurement recommended)
Operating mode: relative
[Hz]
[mA]
[Ω]
[V]
[mA]
2
switching signal; analogue signal; frequency signal; IO-Link; (configurable)
PNP/NPN
2
normally open / normally closed; (parameterisable)
2.5
250
1
4...20; (scalable)
350
yes
pulsed
yes
0...1000
Number of digital outputs: 2; Number of analogue outputs: 1
[s]
[V]
[mA]
18...30 DC
< 100
III
yes
10
Liquid media - absolute operating mode
Setting range
Greatest sensitivity
[m/s]
[m/s]
0.04...3
0.04...3
Liquid media - relative operating mode
Setting range
Greatest sensitivity
[m/s]
[m/s]
0.04...6
0.04...3
Gases - operating mode "absolute"
Setting range
Greatest sensitivity
[m/s]
[m/s]
0...100
30...100
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA2000-00 — 28.07.2021 —
SA2000
Flow sensor
SAR12XDBFRKG/US-100
Gases - operating mode "relative"
Setting range
Greatest sensitivity
Accuracy / deviations
Temperature drift
Temperature gradient
Absolute operating mode
Repeatability
Relative operating mode
Accuracy
Repeatability
Temperature monitoring
Temperature drift
Accuracy
Response times
Response time
Temperature monitoring
Dynamic response T05 / T09
Software / programming
Parameter setting options
Interfaces
Communication interface
Transmission type
IO-Link revision
SDCI standard
Profiles
SIO mode
Required master port type
Process data analogue
Process data binary
Min. process cycle time
[ms]
Type of operation
Supported DeviceIDs
Factory setting / ModE = (REL)
ModE = (LIQU)
ModE = (GAS)
Operating conditions
Ambient temperature
Storage temperature
Protection
[°C]
[°C]
-40...80
-40...100
IP 65; IP 67
IO-Link
COM2 (38,4 kBaud)
1.1
IEC 61131-9
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum
sensitivity under the following conditions:; water: 20...70 °C; inlet
length: 1.5 m; DN25 (DIN 2448); mounting position according to
instructions; Accuracy can differ for other media and mounting positions.)
0,05 m/s; (water; flow velocity: 0,05...3 m/s)
0,05 m/s; (water; flow velocity: 0,05...3 m/s)
[cm/s x 1/K]
[K/min]
0,003 m/s x 1/K (< 20 °C; > 70 °C)
100
[m/s]
[m/s]
0...200
30...100
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA2000-00 — 28.07.2021 —
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA2000-00 — 28.07.2021 —
frequency output volumetric flow quantity monitoring
IO-Link
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA2000-00 — 28.07.2021 —
[i=s]This post was last edited by bqgup on 2018-8-21 12:52[/i] This post teaches you how to design your own DC power supply, set the voltage and current by yourself, and select capacitors through theo...
I wish you all a happy new year. In the new year, you will not be caught for slacking off, your code will not have any bugs, your computer will not freeze, and you will not miss a card after get off w...
PROFIBUS, as a standard fieldbus communication method, is accepted and adopted by more and more customers and suppliers. Now Siemens' high-precision integrated ultrasonic level meter SITRANS Probe LU ...
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
When the WDP500-2A plane grating monochromator is used to test the emission wavelength of a high-power laser diode at different currents, the matching of the laser diode has the disadvantages of lo...[Details]
China's new energy vehicles are in a transition period from research and development to real industrial development. In 2012, with the intensive launch of new energy vehicle policy planning, the de...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
0 Introduction
With the rise and continuous improvement of the solid-state lighting industry, light-emitting diodes (LEDs) have become an alternative lighting technology and are gr...[Details]
LED lighting: Basic circuit design can be completed in as little as one day
Semiconductor manufacturers are also getting involved in the LED lighting business. The power circuit of LED req...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]
1 Introduction
With the improvement of people's quality of life, lamps are no longer just basic indoor lighting tools, but also a kind of practical art for architectural decoration. When ther...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]