ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM7004-02 — 12.08.2015 —
SM7004
Magnetic-inductive flow meter
SMR34GGX50KG/US100
Outputs
Total number of outputs
Output signal
Number of analogue outputs
Analogue current output
Max. load
Overload protection
Measuring/setting range
Measuring range
Display range
Resolution
Analogue start point ASP
Analogue end point AEP
In steps of
Temperature monitoring
Measuring range
Resolution
Analogue start point
Analogue end point
In steps of
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring
range)
Repeatability
Temperature monitoring
Accuracy
Response times
Flow monitoring
Response time
Damping for the switching
output dAP
Temperature monitoring
Dynamic response T05 / T09
Operating conditions
Ambient temperature
Storage temperature
Protection
[°C]
[°C]
-10...60
-25...80
IP 67
[s]
T09 = 20 (Q > 1 l/min)
[s]
[s]
0.15; (dAP = 0, T19)
0...3
[K]
± 2,5 (Q > 1 l/min)
± (2 % MW + 0,5 % MEW)
± 0,2% MEW
[°C]
[°C]
[°C]
[°C]
[°C]
-20...80
0.2
-20...60
0...80
0.2
0.2...50 l/min
-60...60 l/min
0.1 l/min
0...40 l/min
10...50 l/min
0.1 l/min
0.02...13.22 gpm
-15.86...15.86 gpm
0.02 gpm
0...10.58 gpm
2.64...13.22 gpm
0.02 gpm
[mA]
[Ω]
2
analogue signal
2
4...20; (scalable)
500
yes
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM7004-02 — 12.08.2015 —
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
500 V withstand voltage (V DC)
008MI
-
± 2,5 % FS
0,01 m³/h
-
3 m³/h
20 g (11 ms)
5 g (10...2000 Hz)
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM7004-02 — 12.08.2015 —
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM7004-02 — 12.08.2015 —