EEWORLDEEWORLDEEWORLD

Part Number

Search

204-805-08M10-13PPCGC

Description
Circular Connector, 13 Contact(s), Aluminum Alloy, Male, Solder Terminal, Receptacle,
CategoryThe connector    The connector   
File Size169KB,3 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

204-805-08M10-13PPCGC Overview

Circular Connector, 13 Contact(s), Aluminum Alloy, Male, Solder Terminal, Receptacle,

204-805-08M10-13PPCGC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT RESISTANT
Filter functionYES
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeBOARD AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size10
Termination typeSOLDER
Total number of contacts13
Base Number Matches1
A
B
C
D
E
F
G
H
J
TABLE I: CONNECTOR MATL/FIN
SYM
MATERIAL
Aluminum
Aluminum
Stainless
Steel
Aluminum
FINISH DESCRIPTION
Electroless Nickel
Cadmium O.D. Over
Electroless Nickel
Electro-Deposited Nickel
Zinc-Nickel Over
Electroless Nickel
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Filter
Filtered “Mighty Mouse”
SERIES 805 FILTERED CONNECTORS
Series 805 Filtered Connectors
feature
triple-start ACME coupling threads.
Available in
Jam Nut
and
Square
Flange
versions, these environmentally
sealed connectors offer aerospace filter
performance in a miniaturized package.
These connectors mate to standard Series
805 plugs.
Consult Factory
for Additional Filter
Types, TVS Diodes, and other Custom
Filter Connector Configurations.
Series 805
Triple-Start
Filter
Connector
Product Code
Insert Arrangement
(See Table III)
Connector
Matl/Fin
(See Table I)
Contact Gender
P
- Pin
S
- Socket
Capacitance Code
(See Table II)
240 - 805 - 02
Shell Style
01
-
Square Flange Receptacle
M
8-7
P
S
P
A
A
Filter Type
P
- Pi
C
- C
Contact Termination
S
- Solder Cup
P
(Shell Style 01 and 07 only)
- PC Tail
(Shell Style 02 and 08 only)
with Solder Cup Contacts and Band Platform
02
-
Square Flange Receptacle
with Printed Circuit Board Contacts
07
-
Jam Nut Receptacle with Solder Cup Contacts
and Band Platform
08
-
Jam Nut Receptacle
with Printed Circuit Board Contacts
Alternate Key
Position
A, B, C, D
(A = Normal)
TABLE III
INSERT ARANGEMENTS
Arr. No.
8-4
8-7
9-10
10-13
11-19
12-26
15-37
18-55
18-85
Contact Contact
Size
Qty.
23
23
23
23
23
23
23
23
23
4
7
10
13
19
26
37
55
85
TABLE II: CAPACITANCE CODE
CODE
A
B
C
D
E
F
G
PI - SECTION (pF)
38,000 - 56,000
32,000 - 45,000
18,000 - 33,000
8,000 - 12,000
3,300 - 5,000
800 - 1,300
400 - 600
C - SECTION (pF)
19,000 - 28,000
16,000 - 22,500
9,000 - 16,500
4,000 - 6,000
1,650 - 2,500
400 - 650
200 - 300
M
NF
ZL
ZN
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
J-10
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Keil4 and Keil5 coexist and do not interfere with each other's setting method
[size=5]Some demo projects use keil4 and some use keil5, so it is very convenient and worry-free to be compatible with both versions on the same computer. Let me share some of my experience[/size] [si...
gxt467138 MEMS sensors
How to choose the correct charging method for electric vehicles
[i=s]This post was last edited by qwqwqw2088 on 2016-6-6 08:47[/i] Although more and more people choose to buy electric cars, it is still a new thing for most electric car owners, and they don’t know ...
qwqwqw2088 Energy Infrastructure?
How to read PANID and channel parameters in ZigBee application layer? Urgent! ! ! ! !
As the title says, how can I read the network's PANID and channel parameters at the application layer, which are the attributes in _NIB?...
weiruiqi120 RF/Wirelessly
MFC ActiveX control cannot respond to WM_DEVICECHANGE message
As the title says, I made a control some time ago, and it could respond to it yesterday, but... There is no WM_DEVICECHANGE in vc6.0 classwizard, so I added the code manually as follows: 1. Add afx_ms...
allanfy Embedded System
ucos information
:victory:...
huzx189 Microchip MCU
AD0832 driver, please help!
In the program, data is output from D0 starting from the falling edge of the fourth pulse, and the lowest bit of data is sent out at the eleventh pulse. The output of one byte of data is completed. So...
北北 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 864  1862  1929  2665  961  18  38  39  54  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号