EEWORLDEEWORLDEEWORLD

Part Number

Search

35823

CategoryTools and equipment    Device suite   
File Size884KB,3 Pages
ManufacturerMENDA/EasyBraid
Download Datasheet Parametric View All

35823 Online Shopping

Suppliers Part Number Price MOQ In stock  
35823 - - View Buy Now

35823 Parametric

Parameter NameAttribute value
category
MakerMENDA/EasyBraid
seriesMenda®
PackageBulk
Accessory typefilter
Supporting use/related productsAnti-static vacuum cleaner 35867, 35868
USER GUIDE TB-4018
ESD Service Vacuum
Operation and Maintenance
Made in the
United States of America
35868 ESD Service Vacuum, 220 VAC, No Power Cord:
35822
Type 2 Filter for Dust and Toner
35825
7 Foot Dissipative Hose
35826
Crevice Tool
35827
Crevice Tool Brush
35828
Wand
35829
Needle Nose Nozzle
35830
Dust Brush
Optional Accessories
Figure 1. ESD Service Vacuum.
35823
Type 1 Filter for Fine Particles
35824
Carrying Strap
Description
Grounding Instructions
The 35867/35868 ESD Service Vacuum is designed
for high-efficiency cleanup of most business equipment
including removing toner and dust. Portability, quick
setup and efficient and safe operation are key features
of this vacuum. It contains a one horsepower, six amp
motor.
This product meets ANSI/ESD S20.20 and is designed
to be used in an ESD protected area. The hose and
accessories are conductive/dissipative so electrostatic
charges will be removed when properly grounded
through the power cord to electrical outlet ground prong.
The ESD Service Vacuum is available in two models:
Item
Description
The 35867 Vacuum is for use on a nominal 120 volt circuit
and has a grounding plug. The 35868 Vacuum is for use
on a nominal 240 volt circuit. Make sure the vacuum is
connected to an outlet having the same configuration as
the plug. No adapter should be used with this vacuum.
Any service on the vacuum should be performed by an
authorized service representative.
Warning:
Improper connection of the equipment-grounding
conductor can result in the risk of electric shock. Check
with a qualified electrician or service person if you are in
doubt as to whether the outlet is properly grounded. Do
not modify the plug provided with the appliance. If the plug
does not fit the outlet, have a proper outlet installed by a
qualified electrician.
Specifications
Electrical
35867
35868
Motor
Suction
Dimensions
Weight
120VAC, 50/60Hz, 6.0amps
220/240VAC, 50/60Hz, 4.25amps
1 Horsepower
Approx. 51”/H20
17.8" L x 7.8" W x 9.3" H
(45.2 cm L x 19.7 cm W x 23.5 cm H)
11 lbs.
35867
ESD Service Vacuum, 120 VAC, US Plug
35868
ESD Service Vacuum, 220 VAC, No Power Cord
Packaging
35867 ESD Service Vacuum, 120 VAC, US Plug:
Includes 8 Foot Power Cord, US Plug
35822
Type 2 Filter for Dust and Toner
35825
7 Foot Dissipative Hose
35826
Crevice Tool
35827
Crevice Tool Brush
35828
Wand
35829
Needle Nose Nozzle
35830
Dust Brush
3651 Walnut Avenue, Chino, CA 91710
Phone: (909) 627-2453 • Web Site:
MendaPump.com
TB-4018
Page 1 of 3 January 2018
© 2018 DESCO INDUSTRIES, INC.
Employee Owned
[TI Wireless Theme Collection] CC2540 wireless module for ECG connection
[i=s]This post was last edited by lonerzf on 2014-12-3 21:36[/i] When I first came into contact with TI Bluetooth 4.0 chip CC2540, I didn't expect that this thing would add so much fun and convenience...
lonerzf Wireless Connectivity
EEWORLD University Hall----Live Replay: Microchip Security Series 15 Simplifies Security Application Design with dsPIC33/PIC24 and ATECC608 Devices
Live Replay: Microchip Security Series 15 Simplifying Security Application Design with dsPIC33/PIC24 and ATECC608 Devices : https://training.eeworld.com.cn/course/6165...
hi5 Integrated technical exchanges
Newlyweds Greetings
Hello everyone, new member joined!...
锐迪芯电子 Analog electronics
Miscellaneous talks on rectification (V)
[align=left][size=3]In circuit theory, there are many quantities that are dual, such as: voltagecurrent, capacitanceinductance, etc. The following table is taken from "Basics of Circuit Analysis by Li...
maychang Power technology
Electronic components relay
[font=楷体_GB2312][size=4]This chapter mainly introduces the classification, selection and precautions of relays. [/size][/font] [font=楷体_GB2312][size=4]Relays[/size][/font]...
lixiaohai8211 Analog electronics
Help a backup power circuit
Hello everyone, I recently designed a terminal, which is usually powered by the mains. When the mains suddenly disappears, the terminal automatically switches to the battery. If the mains is restored,...
jileihello Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2851  1082  2075  2779  2775  58  22  42  56  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号