EEWORLDEEWORLDEEWORLD

Part Number

Search

HWS1000-36

Description
switching power supplies 1055w 36v 29.3A
CategoryPower/power management    The power supply circuit   
File Size57KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance
Download Datasheet Parametric View All

HWS1000-36 Online Shopping

Suppliers Part Number Price MOQ In stock  
HWS1000-36 - - View Buy Now

HWS1000-36 Overview

switching power supplies 1055w 36v 29.3A

HWS1000-36 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTDK Corporation
package instruction,
Reach Compliance Codeunknown
HWS300-1500 Series
Single Output Industrial Power Supplies
Features
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
High Efficiency
Class 1 Div 2 option (/RY suffix)
Wide Range AC Input
Key Market Segments & Applications
Specifications
Model
Input Voltage range (47-63Hz)
Input Current (Typ)
(1)
Inrush Current
(1)
Power Factor
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ)
Leakage Curr. (at 240VAC, 60Hz)
Remote Sense
Indicator
Remote on/off
Parallel operation
DC Good
Remote Adjust (PV)
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
(4)
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certifications (5)
Line Dip
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
-
A
A
-
-
-
V
ms
mA
-
-
-
-
-
-
-
°C
-
-
-
-
-
-
-
-
-
-
g
in
yrs
HWS600
HWS1000
HWS1500
85 - 265VAC or 120 - 330VDC (6)**
5V: 3.8/1.9;
5V: 7.5/3.6;
3.3V: 9.6/5.0;
3.3V: 15.0/8.0;
12-48V: 4.2/2.1
12-48V: 8.1/3.9
5-60V: 13.5/7.0
5-60V: 19.5/10.0
20 / 40
Meets EN61000-3-2
<0.02%/°C
>105% (>101% of peak current for peak current capable models)
See table on page 2 (Recycle AC or remote on/off to reset)
20
<0.75mA
<1.2mA
<1.5mA
Yes
Green LED = ON
Yes (Isolated from output)
Single wire connection (up to 5 units)
Yes
External voltage adjusts output, see options table
-10°C to +70°C, derate linearly to 50% load from 50C to 70C (2, 3)
-30 to +85°C
Operating: 10 - 90%RH, Non operating 10 - 95%RH
Internal fan
Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A)
IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11
1,000
1,600
3,200
3.3-7.5V: 4000; 12V+: 3800
2.4 x 3.23 x 6.5”
3.94 x 3.23 x 6.5”
5 x 3.25 x 9.45”
5 x 3.25 x 11”
Limited lifetime warranty (See TDK-Lambda’s terms and conditions)
(5) UL60601-1, EN60601-1, see options.
UL508; HWS300/600 5V, 12V, 24V & 48V models
(6) Not on HWS1500/ME, /HD or /RY versions
(*) Class 1 Div 2 option (/RY suffix)
(**) Safety certified for AC input only
HWS300
(1) 100/200VAC
(2) HWS start up -20°C. (-40°C see options table)
(3) HWS1000/1500 with 85VAC input: See installation manual
(4) 2kVAC HWS1000/1500 Input to ground
HWS1000: -10 to +71°C. HWS1000-5, HWS1500-3, -5 derate linearly above 40°C
1-800-526-2324 • www.us.tdk-lambda.com/lp/
61
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Switching Power Supply Interest Group 15th Task
Question 14  : 1. Figure (06) is a typical application circuit in the UC1525A manual. Transformer T1 has two secondary windings, which are used to drive a half-bridge circuit. If a full-bridge circuit...
maychang Switching Power Supply Study Group
[Electronic open source project] TCP two-wheeled self-balancing car
1. Project PurposeIn order to promote everyone's determination and courage to learn electronics, and to guide beginners to a cheaper and more hands-on and practical learning path.Use the cheapest tool...
wealding Robotics Development
Help! Does anyone have information about the <>? I need it urgently!
Help! Does anyone have information about the Mobile Phone User Numbering Plan? I need it urgently!!! best...
dn1031 RF/Wirelessly
EE_FPGA USB port driver
PL2303 Driver...
chenzhufly FPGA/CPLD
IO port clock setting problem
I would like to ask, (1) When I only use one IO port and it is used as input, should I enable the IO port when setting the clock? (2) If I do not enable the IO, can I set the IO speed? (3) The DAC of ...
mytostudy stm32/stm8
Omron E6A2
Does anyone know how to connect and use the Omron E6A2 cable? I didn't buy it on Taobao (I applied for it) so I can't find any information. Urgently needed...
萌新本体 DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2915  1773  2282  817  2638  59  36  46  17  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号