bench top power supplies 420w 0V-60v 0A-7A
CategoryPower/power management   
File Size584KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance
Download Datasheet View All

ZUP60-7/LUW Overview

bench top power supplies 420w 0V-60v 0A-7A

ZUP Series
Zero up programmable power supplies
Features
u
Constant Voltage / Constant Current
u
Last Setting Memory
u
Digital Meters
u
Built-in RS232 & RS485 Interface w/ GPIB optional
u
Bench or Rack Mount
u
Embedded Microprocessor Controller
u
Voltage up to 120V, Current up to 132A
Key Market Segments & Applications
Specifications
Model
Load Regulation
Line Regulation
Recovery Time (1)
Temperature Coefficient
Temperature Drift(2)
Up programming response time
Down prog. resp. time (CV)
Down prog. resp. time (CV)
Load Regulation
Line Regulation
Temperature Coefficient
Temperature Drift(2)
Prog Voltage resolution
Prog Voltage accuracy
Prog Current resolution
Prog Current accuracy
Overvoltage Shutdown
Thermal Protection
Display - Voltage
Display - Current
Display - Status
Remote On/Off
Output Good
Voltage & Current Programming
Remote Sense
Communication Interface
Series & Parallel Operation
AC Input Voltage range
Inrush Current (100/200VAC)(3)
Hold Up Time (Typ) at 100VAC
Power Factor Correction
Temperature Range
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration & Shock (non-op.)
Safety Agency Approvals
Conducted & Radiated EMI
Warranty
-
-
ms
-
-
ms
ms
ms
-
-
-
-
-
mV
-
-
V
-
-
-
-
-
-
-
-
-
-
VAC
A
ms
-
-
-
-
-
-
-
-
-
yrs
ZUP20
ZUP36
ZUP60
ZUP80
ZUP120
2mV + 0.005% over 0 - 100% load change
1mV + 0.005% over 85 - 132 or 170 - 265VAC line change
1ms
0.5ms
0.2ms
30ppm/°C following 30 minute warm up
0.01% + 2mV change in output
50 - 60ms
80ms
120ms
50ms (70ms ZUP60-14)
250ms
350ms
400ms
500ms
750ms
600ms
800ms
0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models
0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models
100ppm/°C from rated current after 30 minute warm up time
0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models
Better than 0.028% of rated voltage
.02%+5mV .02%+8mV .02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV
Better than 0.03% of rated voltage
0.4% + 40mA
0 - 7.5
0 - 13
0 - 24
0 - 40
0 - 66
0 - 88
0 - 132
Over temperature protected
3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits
3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits
CV / CC, Alarm, Foldback, Local/Remote, On/Off
TTL signal or dry contact relay
Open Collector
By either Voltage (0-4V) or Resistance (0-4k)
Up to 0.5V compensation per output cable
RS232 & RS485 standard, IEEE488 optional
Series: Up to two units; Parallel: Up to five units in master-slave configuration
85-265VAC (47-63Hz)
15/30A, 200W models, 15A, 400W models, 30A, 800W models
20
Complies with EN61000-3 Class A (0.99 typ)
Operating: 0 - 50°C; Storage: -20 to +70°C
Operating: 30 - 90% RH, Storage 10 - 95%RH
Internal fan
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH
Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G
UL3111-1, EN61010-1, CE Mark
EN55022-B conducted, A radiated, FCC Class B conducted, A radiated, VCCI-2 conducted, -1 radiated
Three Years
(2) Over 8 hour period following 30 minute warm up time
ZUP6
ZUP10
Notes: (1) Recovery to within +/-50mV after load change of 50-100%
(3) 25°C ambient (cold start)
1-800-526-2324 • www.us.tdk-lambda.com/lp/
152
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Bad blocks in NAND flash
1. Why do bad blocks appear? The NAND Flash process cannot guarantee that the NAND Memory Array (an array composed of NAND cells) maintains reliable performance during its life cycle (the charge may n...
fish001 Microcontroller MCU
About EVC4.0 database issues
I searched a lot on the Internet about how to use ADO to access data in EVC4.0. Most of them said that they used ADOCE3.1, which is a bunch of registration of DLLs, and there was an example. I tried i...
macro Embedded System
Please recommend a good soldering iron
[backcolor=white]Please recommend a good soldering iron. I don't want to use the ten-dollar soldering iron anymore. It has a short life and is not easy to use. I want to buy a good 30W soldering iron....
桂花蒸 Analog electronics
Distributed Control Systems
Distributed Control System Distributed control system (DCS) is also called distributed control system, distributed control system, and distributed control system. The industry calls it 4C technology, ...
decho0821 Embedded System
The Embarrassed Generation (Written to students born between 1987 and 1990, the generation living between the 80s and 90s)
Maybe everyone has seen it, but I still repost it, it's classic!!! [size=4][b][font=楷体_GB2312]This is an article on the campus website that has been viewed 80,000 times. If you see this log, please re...
zhangkai0215 Talking
[Show off] I got the electronic scale I exchanged for my chip coins
I was very happy to receive the goods delivered by JD this morning----The scale was well packaged, with a large box inside a small box, and a fixed and cushioned pad inside. I guess these two boxes co...
dontium Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1585  2930  983  696  2656  32  59  20  14  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号