60W DC-DC Regulated Single Output Converter
SKA60
series
¡½
Features :
¡E
2"
¡Ñ
2" compact size
SPECIFICATION
ORDER NO.
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
VOLTAGE ACCURACY
SWITCHING FREQUENCY
Note.3
Note.4
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
5V
1.2 ~ 12A
60W
2:1 wide input range
High efficiency up to 93%
1500VDC I/O isolation
Built-in remote ON / OFF control
Built-in remote sense
Trimming output 10%
Comply with CE / FCC without external components
Protections: Short circuit / Overload / Input and output Over voltage
Cooling by free air convection
Six-sided shield metal case
100% burn-in test
Low cost / High reliability
Output 3.3V available
2 years warranty
¡Ó
SKA60A-05 SKA60B-05 SKA60C-05 SKA60A-12 SKA60B-12 SKA60C-12 SKA60A-15 SKA60B-15 SKA60C-15
12V
0.5 ~ 5A
80mVp-p
15V
0.4 ~ 4A
100mVp-p
RIPPLE & NOISE (max.)
Note.2
60mVp-p
¡Ó
0.5%
¡Ó
0.5%
¡Ó
2.0%
250KHz min.
220uF
EXTERNAL CAPACITANCE LOAD (max.)
1000uF
EXTERNAL TRIM Adj. RANGE(Typ.)
10%
A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC
VOLTAGE RANGE
91%
90.5%
92%
92%
EFFICIENCY (Typ.)
¡Ó
100uF
92.5%
2715mA
120mA
92%
1370mA
60mA
92%
5400mA
160mA
93%
2690mA
120mA
92.5%
1370mA
85mA
INPUT
DC CURRENT
FILTER
REMOTE CONTROL
PROTECTION
OVER CURRENT
Full load 5505mA
No load
185mA
Pi network
2775mA
120mA
1370mA
60mA
5445mA
160mA
Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short
Fuse recommended
110% ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
All output equipped with short circuit
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Input(Typ.) A: >20 ~ 25VDC B: >40 ~ 50VDC C: >80 ~ 100VDC input voltage Protection type : Shut down o/p voltage, recovers automatically after fault condition is removed
Output(Typ.) 5Vo : 7V ~ 8.95V ; 12Vo : 15V ~ 19.2V ; 15Vo : 18V ~ 23.3V
-40 ~ +70
+100
PROTECTION SHORT CIRCUIT
(Note. 5)
OVER VOLTAGE
WORKING TEMP.
CASE TEMP.
¢J
max.
¢J
(Refer to "Derating Curve")
¢J
Protection type : Clamp by TVS diode
20% ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
-55 ~ +105 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
TEMP. COEFFICIENT
¡Ó
¢J
¢J
VIBRATION
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC EMISSION
EMC
EMC IMMUNITY
OTHERS
DIMENSION
WEIGHT
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:1.5KVDC
I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH
¢J
Compliance to EN55022 Class A, FCC part 15 Class A without external components
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H)
67g
Mechanical Specification
Unit:mm(inch)
50.8 (2.00)
7.62 5.08 7.62 5.08
(0.3) (0.2) (0.3) (0.2)
Pin Configuration
Pin No. Output
1
2
3
4
R.C
-Vin
+Vin
-R.S
Derating Curve
+R.S
+Vout
-Vout
TRIM
Pin No. Output
5
6
7
8
100
5.8 (0.23)
11 (0.43)
4
56
78
50.8 (2.00)
45.7 (1.8)
BOTTOM
VIEW
3 2
5.08
(0.2)
External Output Trimming
2
-Vin
+Vout
6
7
LOAD
VR
VR
3
+Vin
TRIM
8
UP
DOWN
1M
LOAD (%)
50
1
1.0
£[
-40
0
25
50 55
10.16 12.7
(0.4) (0.5)
£r
(0.04
¡Ó
0.005)
-Vout
Ta (
TRIMPOT
¢J
)
70
90
NOTE
1.All parameters are specified at normal input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
File Name:SKA60-SPEC 2012-07-18
¢J