The REC7.5-xxxxSRW/DRW-series offer single and dual regulated outputs in a DIP24 package
with 1kV, 2kV or 3kV options and are suitable for higher power industrial or medical
applications. Remote on/off control is possible with the /CTRL option and SMD pinning is
offered with the /SMD option. The converters can deliver 140% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents.
7.5 Watt
DIP24
&
SMD
Single
&
Dual
Output
Selection Guide
Part
Number
REC7.5-xx3.3SRW/H*/A/M
REC7.5-xx05SRW/H*/A/M
REC7.5-xx09SRW/H*/A/M
REC7.5-xx12SRW/H*/A/M
REC7.5-xx15SRW/H*/A/M
REC7.5-xx05DRW/H*/A/M
REC7.5-xx09DRW/H*/A/M
REC7.5-xx12DRW/H*/A/M
REC7.5-xx15DRW/H*/A/M
Input
Voltage
(VDC)
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
9-18, 18-36, 36-72
Output
Voltage
(VDC)
3.3
5
9
12
15
±5
±9
±12
±15
Output
Current
(mA)
1800
1500
833
625
500
±750
±417
±312
±250
Efficiency
(%)
78
79-82
81-84
82-85
83-86
79-82
81-84
82-85
83-86
Max
Capacitive
Load
(1)
6800µF
6800µF
6800µF
6800µF
6800µF
±2200µF
±2200µF
±2200µF
±2200µF
2011/65/EU
6/6
RoHS
E-358085
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
* add suffix /H1 for 1kVDC Isolation, /H2 for 2kVDC isolation or /H3
for 3kVDC Isolation (not available in H3/A/M/SMD combination)
* add suffix “/SMD” for SMD package, e.g. REC7.5-2405DRW/H1/A/M/SMD
* add suffix “/CTRL” for Remote Pin option
* add suffix „-R“ for Tape and Reel Packaging (only for SMD type available)
e.g. REC7.5-2405DRW/H1/A/M/SMD/CTRL-R
no plastic case is available for REC7.5
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-72Vin = 48
REC 7.5
Derating-Graph
(Ambient Temperature)
100
80
Output Power (%)
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Single
Efficiency / Load
100
80
60
40
Dual
Efficiency / Load
100
80
60
60
40
30
20
0
Safe Operating Area
2412
4805
2409D
4815D
-40
0
50
85 100
71
150
483.3
Efficiency %
4812
40
20
0
2405D
2412D
Operating Temperature °C
Efficiency %
20
0
0% 20%
40%
60%
Total Output current (%)
80%
100%
0% 20%
40%
60%
Total Output current (%)
80%
100%
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
Refer to Application Notes
www.recom-power.com
REV: 0/2015
E-157
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation (25% to 100% full load )
Minimum Load
Output Ripple and Noise (at 20MHz BW)
Operating Frequency (Full Load)
Input Filter
Efficiency at Full Load
No Load Power Consumption
Isolation Voltage
H1-Suffix
H2-Suffix
H3-Suffix
Isolation Capacitance
Isolation Resistance
REC7.5-S_DRW/H*/A/M
Series
2:1
±2% max.
0.4% max.
0.8% max.
3.3V output type
5, 9, 12 and 15V output types
10%
(2)
100mVp-p max.
50mVp-p max.
150kHz min. / 240kHz max.
PI Network
see Selection Guide
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
300mW max.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
50pFtyp.
1 GΩ min.
Continuous, Auto Restart
-40°C to +71°C (see Graph)
-55°C to +125°C
95% RH
Natural convection
Nickel Plated Metal with Non-Conductive Base
12°C/W
16g
15 pcs per Tube
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Short Circuit Protection (Max temp. = 50°C during short circuit conditions)
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Case Material
Thermal Impedance
Package Weight
Packing Quantity
REC 7.5
MTBF (+25°C)
(+71°C)
}
Detailed Information see
Application Notes chapter "MTBF"
using MIL-HDBK 217F
using MIL-HDBK 217F
800 x 10
3
hours
>200 x 10
3
hours
UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
EN60950-1:2006 +A12:2011
Certifications
UL General Safety
EN General Safety
EN Medical Safety
Notes
Note 1:
Note 2:
Report: E358085
Report: SPCLVD1212007
Report: MDD1205098-3 + RM1205098-3
IEC/EN 60601-1 3rd Edition; Medical Report + ISO14971 Risk Assessment
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
The REC 7.5 series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
Typical Characteristics
Overload Response
100
Vout (% nominal)
75
50
25
0
0
50
100
120
140
160
180
200
% of Rated Load
E-158
REV: 0/2015
www.recom-power.com
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
REC7.5-S_DRW/H*/A/M
Series
20.30
10.50
3.8
+0.5 /-0.25
24 PIN DIP Package
32.00
Pin Connections DIP24
Pin #
1
2
15.24
3
9
11
14
16
22
23
2.54
Top View
Single
–Vin
–Vin
NC
NC
+Vout
– Vout
+Vin
+Vin
Dual
–Vin
–Vin
Com
–Vout
+Vout
Com
+Vin
+Vin
CTRL/No Pin CTRL/No Pin
4.60
0.51
Recommended Footprint Details
1.00 ø+0.15/0
(1) 2 3
Bottom View
23 22
16
14
9
11
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
2.54
24 PIN SMD Package
32.00
31.40
11.20
/H3/A/M/SMD combination is not allowed
19.90
10.90
3.81
6.35
20.30
25.40
Pin Connections DIP24 SMD
Pin #
Single
CTRL/NC
–Vin
–Vin
NC
NC
+Vout
– Vout
+Vin
+Vin
Dual
CTRL/NC
–Vin
–Vin
Com
–Vout
+Vout
Com
+Vin
+Vin
NC
NC
2.54
1
2
3
9
11
14
2.03
16
22
23
REC 7.5
Recommended Footprint Details
Pin area
0.1 x 0.50
1 2 3 4 5
0.50
9 10 11 12
2.54
1.54
23.40
Bottom View
24 23 22 21 20
16 15 14 13
26.67
24.64
1
Top View
1,4,5,10,12
13,15,20,21,24
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
11 x 2.54
27.94
CTRL Option
Vin+
Fuse
22,23
2,3
ON = Open or 0V< Vctrl <1.2V
OFF = 2.2V< Vctrl <12V
0V
RECx-xxxx/CTRL
CTRL
1
1kW
1N4148
TTL Input
Off
On
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E coins can be used to buy things on designated websites, but I think the restrictions are a bit too big. For example, I bought a bread machine in the past, but I left it there after using it for a wh...
Is it more promising than learning other general single-chip microcomputers? What relevant knowledge should a beginner have? Answer: Generally, there is a difference in the level of embedded systems b...
The power ripple index of the DC/DC module is a very important parameter. A clean power supply is the premise for the stable operation of digital circuits and an important guarantee for the various pa...
I was looking for information today and suddenly found a Chinese version of the manual, hahahaha!!! http://www.ti.com.cn/product/cn/msp430g2413 The first document seems to be only available for the G ...
[color=#333333]Hello everyone, which pressure sensor has a power supply voltage of about 3V, a pressure measurement range of 0~10KPa (gauge pressure), and an output analog signal of 0 to 2.5V? Can any...
I just received mini2440 from Youshan, thank you very much for their support. I used qq2440 for a while, the NANDFLASH on it is 64M while mini2440 is 128M. Yesterday I saw a CD with 64M and 128M burni...
introduction
my country has a vast territory and a large population. The scale of housing construction is huge, and the amount of residential construction is large and wide. It is still on t...[Details]
In recent years, the market for mobile/portable devices such as smartphones and laptops has continued to grow rapidly. While these products continue to integrate more new features to enhance the ...[Details]
1. Introduction
Light control circuit plays a vital role in urban street lamps or corridor lighting. With light control circuit, the lights can be automatically turned on and off according to ...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]
TC9012F is a universal CMOS large-scale integrated circuit for infrared remote control signal transmission, suitable for remote control of TV, VTR, laser player and other equipment. In the market, ...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
Distributed Wireless Communication System (DWCS) uses distributed antennas, distributed processing control, joint signal processing and other technologies to improve the system's spectrum efficie...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
For battery-powered portable devices, in addition to breaking through the limitations of processing power, the performance of portable system power supplies also needs to be continuously improved. ...[Details]
Leakage current is generated by parasitic resistance paths between the measurement circuit and a nearby voltage source. This current can significantly reduce the accuracy of low current measurement...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
introduction
Temperature and humidity are the main environmental parameters of industrial and agricultural production. It is of great significance to measure them accurately and timely. Using a s...[Details]