EEWORLDEEWORLDEEWORLD

Part Number

Search

27E892

Description
27E892=SOCKET,KRPA,11,OCTAL,PO
CategoryThe connector    socket   
File Size200KB,6 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric Compare View All

27E892 Online Shopping

Suppliers Part Number Price MOQ In stock  
27E892 - - View Buy Now

27E892 Overview

27E892=SOCKET,KRPA,11,OCTAL,PO

27E892 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time11 weeks
Contact to complete cooperationNOT SPECIFIED
Contact materialNOT SPECIFIED
Device slot typeRELAY SOCKET
Type of equipment usedRELAY
Number of contacts11
Base Number Matches1
Catalog 1308242
Issued 3-03
P&B
DIN Rail Mount
Screw Terminal Socket
Track Mounting System
File E59244
File LR35144
Features
Sockets mount on standard 35mm DIN track & P&B “top hat” track.
Spring loaded integral clip holds sockets securely to the track.
Small screwdriver can be used to release sockets from track.
Any available hold-down springs must be ordered separately. See Relay
& Socket Usage Chart beginning on page 747.
• End clips can be used to further stabilize sockets on track.
Location of Socket Dimensions
Typical Relay
KRPA (DPDT)
KRPA (3PDT)
KUP
KH, PCL
K10, PCLH
RT (code 1)
RT (codes 3 & 5)
MT (DPDT)
MT (3PDT)
RM
PT (DPDT)
PT (3PDT)
PT (4PDT)
Base
8-pin octal-type
11-pin octal-type
11-blade square
14-blade square
8-blade square
5-blade square
8-blade square
8-pin octal-type
11-pin octal-type
11-blade square
8-blade square
11-blade square
14-blade square
Socket Part Number
27E891
27E892
27E893
27E894
27E895
RT78624
RT87625
MT78755
MT78750
RM78705
PT78702
PT78703
PT78704
Page
741
741
730
712
722
452
452
743
743
736
719
719
719
24A110 – DIN Rail Style Mounting Track
24A110 mounting track is designed to accept snap-mount sockets, as well
as all other P&B screw terminal sockets. Track is made of lightweight,
sturdy extruded aluminum and is shipped in three-foot (914cm) lengths with
mounting holes on six-inch (152mm) centers. Track can be cut to shorter
lengths or used end-to-end.
36.00
±
.060
(914.4
±
1.52)
1.375
±
.010
(34.93
±
.254)
3.00
(76.2)
6.00
(152.4)
.750
(19.05)
.187
(4.75)
.405
±
.0 07
(10.29
±
.178)
24A071 & 40G432 – End Clip
24A071 steel mounting clip with one #6-32 screw 7/16" (11.1mm) long is
used with a 40G432 insulator to prevent sockets from moving sideways or
sliding off the end of the track.
40G432
24A071
Our authorized distributors are more like to stock the items listed below in boldface.
Part Number
24A110
24A071
40G432
Dimensions are shown for
reference purposes only.
Description
DIN rail style extruded aluminum mounting track for DIN or standard sockets.
Steel mounting clip with one #6-32 screw 7/16" (11.1mm) long. Use with 40G432 below to make end clip.
Plastic insulator. Use with 24A071 above to make end clip.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
747
Refer to inside back cover.

27E892 Related Products

27E892 27E891 27E895 27E893 27E894
Description 27E892=SOCKET,KRPA,11,OCTAL,PO 27E891=SOCKET,KRPA,8,OCTAL,POL 27E895=SOCKET,K10,8,QC,POLY,NA 27E893=SOCKET,KU,11,QC,POLY,NA- 27E894=SOCKET,KH,14,SCW,POLY,N
Is it Rohs certified? conform to conform to conform to conform to conform to
Reach Compliance Code compliant compliant compliant compliant compliant
ECCN code EAR99 EAR99 EAR99 EAR99 EAR99
Contact to complete cooperation NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED TIN
Device slot type RELAY SOCKET RELAY SOCKET RELAY SOCKET RELAY SOCKET RELAY SOCKET
Base Number Matches 1 1 1 1 1
Factory Lead Time 11 weeks 8 weeks 11 weeks - 11 weeks
Contact material NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED -
Number of contacts 11 8 - 3 4
About WINCE network issues
Simply put, the NK.NB0 I compiled cannot obtain a normal address from the router. The addresses I finally get are all private addresses such as 169.254.*.*. If you set a static IP, you cannot ping it....
heyuqi Embedded System
Have you ever received such a blessing text message?
[table][tr][td]It is said that this is the most popular blessing message for the Year of the Tiger. I wonder if it is popular with you? 1 A new year, a new beginning. New hope, new vitality. New oppor...
lixiaohai8211 Talking
Ask: Application of writing macro instructions
SYS(WRITE _WORDS,90) For example, if you want to write the data of @100 into %mw200 of PLC , what should the data of @90 to @96 be? I understand that @90=0; @91=200; @92=?; @93=?; @94=?; @95=100; @96=...
eeleader Industrial Control Electronics
What is the difference between LM4F232 and TM4C123?
What is the difference between LM4F232 and TM4C123? I have an official LM4F232 board. I want to use it to run the TM4C123 TI-RTOS example. Is it possible?...
gongjian32 Microcontroller MCU
PXA310's SPI controlled MCP2515 cannot read?
The SPI of PXA310 is used to control MCP2515, and the transmission is normal. After writing the command word to 2515, the chip status register is read. The MISO pin signal is normal when observed by o...
huangruihua Embedded System
[Keep up with the times] CoIDE 1.4.1 supports STM32F4 and ARM GCC
Since the Cortex M4 chip was launched, there has been a lot of calls from users on the forum for CooCox to support M4 . After a period of hard work, on the happiest day of this month, CooCox released ...
Chocore stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1525  1317  1047  1988  1874  31  27  22  41  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号