Cell Type KR-DHL
Specifications
Nominal Capacity
Nominal Voltage
D
d
4000mAh
1.2V
Trickle
Standard
Trickle
Standard
133mA
400mA
above 48Hrs.
14 to 16Hrs.
0°C to +70°C [+32°F to 158°F]
-20°C to +70°C [ -4°F to 158°F]
-30°C to +70°C [ -22°F to 158°F]
4.2mΩ
(at 1000Hz)
146g/5.15oz
33.2
1.31
0
-0.9
0
-0.04
Charging Current
Charging Time
H
Charge
Ambient
Discharge
Temperature
Storage
mm
inch
mm
inch
mm
inch
H
Dimensions
of
Bare Cell
D
d
58.4
2.299
±0.016
32.3
±0.3
1.272
±0.012
10.0
0.335
±0.4
Internal Impedance (Av.)
(at 50% discharge)
Weight
Dimensions(D)×(H)
(with tube)
×
59.5
×
2.34
0
-1.5
0
-0.06
mm
inch
Typical Characteristics
Charge
Charge : 133mA
1.6
Discharge
(at high rate)
Charge : 400mA×16Hrs.
at 20˚C/68˚F
0˚C/32˚F
Cell Voltage (V)
1.4
Cell Voltage (V)
1.5
20˚C/68˚F
1.2
1.4
40˚C/104˚F
60˚C/140˚F
1.0
1.3
0
6
12
18
24
30
36
42
48
0.8
0
10
20
(2 It)
30
40
50
(1 It)
60
70
80
Charge Time (Hrs.)
Discharge Time (Mins)
Charge
Charge : 400mA
1.6
Discharge
Trickle charge (at high temperature)
0˚C/32˚F
20˚C/68˚F
Cell Voltage (V)
Charge : 133mA×48Hrs.
Charge : 133mA×24Hrs.
Discharge : 4000mA
at 45˚C/113˚F
1.4
Cell Voltage (V)
1.5
1.2
40˚C/104˚F
1.4
1.0
60˚C/140˚F
1.3
0
2
4
6
8
10
12
14
16
0.8
0
10
20
30
40
50
60
70
80
Charge Time (Hrs.)
Discharge Time (Mins)
Discharge
(at low rate)
Charge : 400mA×16Hrs.
at 20˚C/68˚F
Temperature
(Charge & Discharge)
1.4
Available Capacity (%)
100
90
80
70
60
50
40
Cell Voltage (V)
1.2
1.0
Charge Characteristics
Discharge Characteristics
Condition Charge : 133mA×48Hrs.
Discharge : 800mA
(End Volt 1.0V)
0.8
0
(0.5 It)
2
4
(0.2 It)
6
8
10
(0.1 It)
12
14
16
-20
-4
-10
14
0
32
10
50
20
68
30
86
40
104
50
122
60
140
70˚C
158˚F
Discharge Time (Hrs.)
Operating Temperature
CD031203