DS1815
3.3V EconoReset with Push-Pull Output
www.dalsemi.com
FEATURES
Automatically restarts a microprocessor after
power failure
Maintains reset for 150 ms after V
CC
returns
to an in-tolerance condition
Reduces need for discrete components
Precision temperature-compensated voltage
reference and voltage sensor
Accurate 5%, 10% or 20% power monitoring
Low-cost TO-92 or space saving surface-
mount SOT-23 packages available
Push-pull output for low current operation
Operating temperature -40°C to +85°C
PIN ASSIGNMENT
3
1
2
SOT-23 PACKAGE
1 2 3
1 2 3
TO-92 PACKAGE
See Mech.
Drawings Section
PIN DESCRIPTION
TO-92
1
2
3
RST
V
CC
GND
Active Low Reset Output
Power Supply
Ground
SOT-23
1
2
3
RST
V
CC
GND
Active Low Reset Output
Power Supply
Ground
DESCRIPTION
The DS1815 EconoReset uses a precision temperature reference and comparator circuit to monitor the
status of the power supply (V
CC
). When an out-of-tolerance condition is detected, an internal power-fail
signal is generated which forces reset to the active state. When V
CC
returns to an in-tolerance condition,
the reset signal is kept in the active state for approximately 150 ms to allow the power supply and
processor to stabilize.
1 of 5
111999
DS1815
OPERATION - POWER MONITOR
The DS1815 provides the functions of detecting out-of-tolerance power supply conditions and warning a
processor-based system of impending power failure. When V
CC
is detected as out of tolerance, the
RST
signal is asserted. On power-up,
RST
is kept active for approximately 150 ms after the power supply has
reached the selected tolerance. This allows the power supply and microprocessor to stabilize before
RST
is released.
BLOCK DIAGRAM (CMOS OUTPUT)
Figure 1
APPLICATION EXAMPLE
Figure 2
APPLICATION DIAGRAM:
RST
VALID TO 0 VOLTS V
CC
ON THE DS1815
Figure 3
2 of 5
DS1815
TIMING DIAGRAM: POWER-UP
Figure 4
TIMING DIAGRAM: POWER-DOWN
Figure 5
3 of 5
DS1815
ABSOLUTE MAXIMUM RATINGS*
Voltage on V
CC
Pin Relative to Ground
Voltage on
RST
Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
-0.5V to +7.0V
-0.5V to +5V
CC
+0.5V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
Supply Voltage
SYMBOL
V
CC
MIN
0.0
TYP
MAX
5.5
(-40°C to +85°C)
UNITS
V
NOTES
1
DC ELECTRICAL CHARACTERISTICS
PARAMETER
Output Voltage @ -500
µA
Output Current @ 2.4 V
Output Current @ 0.4 V
Operating Current V
CC
< 5.5
V
CC
Trip Point (DS1815-5)
V
CC
Trip Point (DS1815-10)
V
CC
Trip Point (DS1815-15)
Output Capacitance
SYMBOL
V
OH
I
OH
I
OL
I
CC
V
CCTP
V
CCTP
V
CCTP
C
OUT
(-40°C to +85°C; V
CC
=1.2V to 5.5V)
MIN
V
CC
-0.5V
+10
28
2.98
2.80
2.47
3.06
2.88
2.55
35
3.15
2.97
2.64
10
TYP
V
CC
-0.1V
350
MAX
UNITS
V
µA
mA
µA
V
V
V
pF
NOTES
1
2
2
3
1
1
1
AC ELECTRICAL CHARACTERISTICS
PARAMETER
RESET Active Time
V
CC
Detect to
RST
V
CC
Slew Rate
(V
CCTP
(MAX) to V
CCTP
(MIN))
V
CC
Slew Rate
(V
CCTP
(MIN) to V
CCTP
(MAX))
V
CC
Detect to
RST
SYMBOL
t
RST
t
RPD
t
F
t
R
t
RPU
(-40°C to +85°C; V
CC
=1.2V to 5.5V)
MIN
100
300
0
100
150
250
TYP
150
2
MAX
250
5
UNITS
ms
µs
µs
ns
ms
4, 5
6
NOTES
4
4 of 5
DS1815
NOTES:
1. All voltages are referenced to ground.
2. Measured with V
CC
≥
2.7V.
3. Measured with
RST
output open.
4. Measured with 2.7V
≤
V
CC
≤
3.3V.
5. t
R
= 5
µs.
6. The t
F
value is for reference in defining values for T
RPD
and should not be considered a requirement
for proper operation or use of the device.
PART MARKING CODES
“A”, “B”, &“C” represent the device type.
810 . . . . DS1810
811 . . . . DS1811
812 . . . . DS1812
813 . . . . DS1813
815 . . . . DS1815
816 . . . . DS1816
817 . . . . DS1817
818 . . . . DS1818
“D” represents the device tolerance.
A . . . . . . 5%
B . . . . . . 10%
C . . . . . . 15%
D . . . . . . 20%
5 of 5