Embedded Power for
Business-Critical Continuity
LPT60 Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Triple
Rev. 03.24.08
LPT60 Series
1 of 3
RoHS
Electrical Specifications
Special Features
•
•
•
•
•
•
•
•
•
•
Universal input
3" x 5" footprint
Remote sense on main output
Built-in EMI filter
Low output ripple
Adjustable main output
Overvoltage protection
Overload protection
110 KHz switching frequency
LPX60 enclosure kit available
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI:
85-264VAC
120-300VDC
47-440Hz
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1.5A max. (RMS) @ 115VAC
70% typical at full load (60% for LPT61)
FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
Safety ground
leakage current:
Output
Maximum Power:
Cross regulation:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
Remote sense:
60W for convection (LPT61, 35W);
80W with 30CFW forced air (LPT61, 55W)
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
Safety
0805/EN60950 (IEC950)
11774-3336-1255
(LC #86665)
UL:
UL1950
E132002
CSA:
CSA 22.2-234 Level 3
LR53982C
NEMKO:
EN 60950/EMKO-TUE
P95100123
(74-sec) 203
CB:
Certificate and report
1518, 1519, 1520
CE:
Mark (LVD)
VDE:
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
0° to 50°C ambient derate each output at 2.5% per degree
from 50° to 70°C, -20°C startup
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell
at four major resonances 0.75G peak 5 Hz to 500 Hz,
operational
-40° to 85°C
±.04% per °C
>550,000 hours at full load and 25°C ambient conditions
Rev. 03.24.08
LPT60 Series
2 of 3
Storage temperature:
Temperature coefficient:
MTBF demonstrated:
Ordering Information
Model
Number
LPT61
Output
Voltage
+3.3V
+5V
+12V
+5V
+12V
-12V
+5V
+15V
-15V
+5V
+12V
-5V
+5V
+24V
+12V
Minimum
Load
0.7A
0A
0A
0.7A
0.3A
0A
0.7A
0.3A
0A
0.7A
0.3A
0A
0.7A
0.1A
0A
Maximum Load
with Convnection
cooling
5A
2.5A
0.5A
7A
3A
0.7A
7A
2.8A
0.7A
7A
3A
0.7A
7A
1.5A
0.7A
Maximum Load
with 30CFM
Forced Air
8.5A
3.0A
1.0A
8A
3.5A
1A
8A
3.3A
1A
8A
3.5A
1A
8A
2.0A
1A
Peak Load
1
9.5A
3.3A
1A
10A
6A
1.5A
10A
4A
1.5A
10A
6A
1.5A
10A
3A
1.5A
Regulation
2
±2%
±2%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±7%
±5%
Ripple P/P (PARD)
3
50mV
50mV
120mV
50mV
120mV
120mV
50mV
150mV
150mV
50mV
120mV
50mV
50mV
240mV
120mV
LPT62
LPT63
LPT64
LPT65
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
Power Derating Curve
80W
30 CFM Forced Air Cooling
Output
Power
(Watts)
60W
40W
30W
40W
20W
0W
Natural
Convection
Cooling
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
0.22"
(5.6)
M1
GND
SK201
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Rev. 03.24.08
LPT60 Series
3 of 3
M2
+
_
Remote Sense
Connector
Voltage
Adj. Pot
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
3.00"
(76.2)
2.55"
(64.8)
SK 1
1
3
N
L
1
2
3
4
5
6
SK 2
Asia (HK)
0.15" (4)
DIA (4 places)
0.22"
(5.6)
4.56"
(115.8)
5.00"
(127)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
1.69"
(42.9)
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
0.12"
(3)
Pin Assignments
Connector LPT61
SK1-1
SK1-3
SK2-1
SK2- 2
SK2- 3
SK2-4
SK2-5
SK2-6
SK201-1
SK201-2
Neutral
Line
5V
3.3V
3.3V
Common
Common
+12V
+Sense
-Sense
LPT62
Neutral
Line
+12V
+5V
+5V
Common
Common
-12V
+Sense
-Sense
LPT63
Neutral
Line
+15V
+5V
+5V
Common
Common
-15V
+Sense
-Sense
LPT64
Neutral
Line
+12V
+5V
+5V
Common
Common
-5V
+Sense
-Sense
LPT65
Neutral
Line
+24V
+5V
+5V
Common
Common
+12V
+Sense
-Sense
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
Mating Connectors
AC Input:
DC Outputs:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
PINS: 08-58-0111
Molex 09-50-8061 (USA)
09-91-0600 (UK)
PINS: 08-52-0113
Remote Sense: Molex 22-01-2025
PINS: 08-52-0113
Astec Connector Kit #70-841-006, includes all of the above
1.
2.
3.
4.
5.
6.
7.
Specifications subject to change without notice.
All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm)
Mounting holes M1 and M2 should be grounded for EMI purposes.
Mounting hole M1 is safety ground connection.
Specifications are for convection rating at factory settings at 115 VAC input,
25°C unless otherwise stated.
Warranty: 2 year
Weight: 0.75lbs/0.34kg