TPS150
TOTAL POWER INT'L
KEY FEATURES
SWITCHING MODE 130W U CHANNEL POWER SUPPLIES
*Universal
input
*Built-in EMI filter
*Optional remote sense on main output
*Optional constant current charger
*Optional Power Good signal/Optional cover
*Optional±12VDC/±24VDC/±48VDC input
APPLICATIONS
*Telecommunications/Medical
machines
*Computer peripherals/Business machines
*Test & industrial equipments
ELECTRICAL SPECIFICATIONS
*Input range-----------90~264 VAC, auto ranging
*Frequency------------47~63Hz
*Inrush current--------40A typical, Cold start
@25℃,115VAC
*Efficiency------------65%~85% typical at full load
*EMI filter------------ FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
EMI & EMC
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE,EN 61000-3-2 (Class A) (Optional) and –3;
EN 61000-4-2,-3,-4,-5,-6 and -11
INPUT
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601 (EMI Class A)(COMPLY WITH)
OUTPUT
*Maximum power----130W convection (Refer next page)
“Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/- 0.5% per inquiry)
ENVIRONMENTAL
*Operating temperature :
0 to
50℃
ambient; derate each output at 2.5% per
degree from 50℃to 70℃
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85℃
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25℃ambient
conditions
Power Derating Curve
180W
130W
Output
Power
80W
(Watts)
30W
Natural
Convection
Cooling
0
10
20
30
40
50
60
70
65W
Ambient Temperature(
°
C)
PPS150
MODEL
OUTPUTVO ADJUSTMENT
LTAGE
RANGE
MAXIMUM
SWITCHING MODE 130W U CHANNEL POWER SUPPLIES
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
OUTPUTCURRENT
TRIPLE OUTPUT MODEL SELECTION CHART
TPS150-39
+18V
- 18V
+ 5V
±10%
Typical
Fixed
Fixed
4A
4A
2A
6.4A
6.4A
3.2A
0.4A
0.4A
0.2A
±5%
±5%
±10%
±1%
±1%
±1%
210W Typical
QUAD OUTPUT MODEL SELECTION CHART
+ 5V
TPS150-40
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
Fixed
±10%
Typical
Fixed
Fixed
15A
5.3A
0.8A
0.8A
15A
4.2A
1.5A
1.5A
15A
2.7A
1.5A
1.5A
9A
3.5A
1.5A
3A
9A
1.5A
1.5A
1.5A
15A
2A
1A
1.5A
4A
1.25A
0.8A
4A
13A
1.1A
1.1A
1.1A
12.5A
9A
2.5A
2.5A
12.5A
9A
2.5A
24A
8.5A
1.3A
1.3A
24A
6.7A
2.4A
2.4A
24A
4.3A
2.4A
2.4A
14.4A
5.6A
2.4A
4.8A
14.4A
2.4A
2.4A
2.4A
24A
8.5A
1.6A
2.4A
6.4A
2A
1.3A
6.4A
20.8A
1.76A
1.76A
1.76A
20A
14.4A
4A
4A
20A
14.4A
4A
1.5A
0.53A
0.08A
0.08A
1.5A
0.42A
0.15A
0.15A
1.5A
0.27A
0.15A
0.15A
0.9A
0.35A
0.15A
0.3A
0.9A
0.15A
0.15A
0.15A
1.5A
0.2A
0.1A
0.15A
0.4A
0.13A
0.08A
0.4A
1.3A
0.11A
0.11A
0.11A
1.25A
0.9A
0.25A
0.25A
1.25A
0.9A
0.25A
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±10%
±5%
±5%
±10%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1.5%
±1%
±1%
±1%
±1.5%
±1%
210W Typical
210W Typical
210W Typical
210W Typical
210W Typical
210W Typical
210W Typical
210W Typical
210W Typical
210W Typical
+12V
- 12V
-5V
+ 5V
+12V
- 12V
-5V
+ 5V
+12V
- 15V
+15V
+ 5V
+12V
- 12V
- 15V
+ 5V
+12V
- 12V
+48V
+ 5V
+12V
- 12V
+24V
+ 5V
- 15V
+15V
+24V
+ 5V
+15V
- 15V
+48V
+ 5V
+3.3V
+12V
-12V
+ 5V
+3.3V
+12V
TPS150-41
TPS150-42
TPS150-43
TPS150-44
TPS150-45Y
TPS150-46
TPS150-47
TPS150-48
TPS150-49
Fixed
±10%
±1%
+24V
1A
1.6A
0.1A
NOTES:
1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1μF and 47μF Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated, if 12 VDC input version; 25% derated if additional cover.