EEWORLDEEWORLDEEWORLD

Part Number

Search

19-002-173TL

Description
Interconnection Device
CategoryThe connector    The connector   
File Size220KB,2 Pages
ManufacturerAries Electronics
Download Datasheet Parametric View All

19-002-173TL Overview

Interconnection Device

19-002-173TL Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 171 thru 173
Flat Pin Staked Flex Jumpers
FEATURES:
• Aries Flat Pin Staked Flex Jumpers combine thin, flexible, solid Copper
conductors embedded between layers of tough, flexible, flame-
retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See DataSheet
11019
for 90° Pin Staked Flex Jumpers.
• For RoHS applications for Lead-Free Soldering use HT Cable.
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant
Polyester (Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide
(Kapton) insulation with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equiva-
lent to that of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper
Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min
Nickel per SAE-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over
50μ” [1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps.
• Cable voltage rating=300 Volts.
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp.).
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp.).
• Operating temperature=-67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square, .150 [3.81]
long minimum.
MOUNTING CONSIDERATIONS:
•Suggested PCB hole size=.032 ± .002 [.81 ± .05] dia.
Note: Aries specializes in custom design and production. In addition to the
standard products shown on this page, special materials, platings, sizes, and
configurations can be furnished, depending on quantities. Aries reserves the
right to change product specifications without notice.
ORDERING INFORMATION
XX-XXXXX-17XXXXXX
Optional Suffix:
HT = High
temp. cable
insulation
Optional Suffix:
TL = Tin/Lead
Plating
Optional Suffix:
P= polarization
stripe along one
edge of cable**
No. of conductors
(4 thru 40)
Kapton is a registered trademark of DuPont
Cable length: “L” in inches:
Min. Cable Length = 2.00” (-002-)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper series:
171: male Tin both ends
172: male Tin/female Tin
173: female Tin both ends
CABLE DETAIL
MALE CONTACT DETAIL
** Aries reserves the right to
ship with or without a polariza-
tion stripe unless otherwise
specified by the customer
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL:(908) 996-6841
FAX:(908) 996-3891
abc
EUROPE
TEL: +44 870 240 0249
FAX: +44 871 919 6033
europe@arieselec.com
11005
REV.I
Page 1 of 2
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Network remote induction card IC card one-card system solution
With the development of science and technology, the improvement of living standards and the acceleration of the pace of modern cities, people are increasingly pursuing more convenient, practical and f...
xyh_521 Industrial Control Electronics
The principles we must follow when contacting UPS power supply
When we first come into contact with UPS power supply, we must understand and abide by the process that the use of UPS power supply must have a set of strict and scientific operating procedures. If yo...
eeleader-mcu Industrial Control Electronics
SensorTag BLE4.0 Development
When developing SensorTag, how to develop if there is no Bluetooth 4.0 device? Is there any solution?...
shmily53 Wireless Connectivity
Challenges and design trends facing power management in next-generation mobile phones
In the future, mobile phones will integrate more functions or features that require power consumption. How to extend the battery life will become a major issue. In combination with the development tre...
songbo Power technology
Damn ARM7 internal clock problem!!!
PREINT = (CLK_Apb_PclkFreq()>>15) -1 ;// Set the reference clock divider CLK_Apb_PclkFreq() / 32768 -1 PREFRAC = (UINT32)CLK_Apb_PclkFreq() & 0x7fff;//CLK_Apb_PclkFreq() - (CLK_Apb_PclkFreq() / 32768)...
prayerwind The Industrial Cloud
MSP430F149 MCU implements uart data receiving interrupt
/******************************************************** Program function: MCU keeps sending data to PC, and displays ASCII characters corresponding to 0~127 on the screen----------------------------...
Aguilera Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2851  1444  2671  650  2345  58  30  54  14  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号