MEDER electronic
LS01 Series
Level Sensors with
Magnetic Floats
DESCRIPTION
Standard liquid level sensor. The sensor has to be
mounted vertically for best results.
Two versions are available:
PP
(Polypropylene) for water applications and
dilute acids
PA
(Polyamide) for use in oil, gasoline (petrol) and
brake fluid
The standard termination is a PVC single wire with
a cross section of 0.25 mm
2
and a length of 500
mm. The cable can be modified on request.
APPLICATIONS
•
Liquid container monitoring in household
appliances, automotive applications, test and
measurement, and control technology.
FEATURES
•
High power switches available
•
Other cables, connectors and colors available
•
Form A (normally open) and Form B (normally-
closed) types are available
•
IP 68 (only to screw thread)
All dimensions in mm [inch]
DIMENSIONS
SWITCHING STATUS
SW12
M8
Form A
Open
Form B
Closed
O-ring
marking
float
YM/P
4.50
[0.177]
[1.673]
10
[0.394]
Closed
Open
Lock washer
ø6.5
[ø0.256]
ø24±0.3
[0.945±0.012]
www.meder.com
297
[0.748]
25.0
[0.984]
19
32.50
[1.280]
42.50
500±10
[19.685±0.39]
5±1
[0.196±0.04]
LS01 Series
Level Sensors with
Magnetic Floats
MEDER electronic
ORDER INFORMATION
Part Number Example
LS01 - 1A66 - PA - 500
1A
is the contact form
66
is the switch model
PA
is the material
500
is the cable length (mm)
W
is the termination
W
Series
LS01 -
Options
Contact
Form
xx
1 Form A
1 Form B
Switch
Model
xx -
66, 85
Material
xx -
PA, PP
Cable
Length
(mm)
xxx
500 *
Termination
x
W
* Other cable lengths available. Standard graduation of length 0.5 m.
For other wire and termination details please contact factory.
TERMINATION
W
The cable cut length includes:
5 mm of wire stripped and tinned
MATERIALS
PA Version
Stem, nut
Float
Seal
PP Version
Stem, nut
Float
Seal
Polypropylene white
Polypropylene white
Nitrile rubber
Polyamide black
Polyamide white with marking
Alternative NBR
Nitrile rubber
www.meder.com
298
MEDER electronic
LS01 Series
Level Sensors with
Magnetic Floats
CONTACT DATA
All Data at 20° C
Contact Ratings
Switching Power
Switching Voltage
Switching Current
Carry Current
Static Contact Resistance
Dynamic Contact Resistance
Insulation Resistance across
Contacts
Breakdown Voltage across
Contact
Operate Time incl. Bounce
Release Time
Capacitance
Environmental Data
Shock Resistance
Vibration Resistance
Ambient Temperature
Stock Temperature
Soldering Temperature
1/2 sinus wave duration 11 ms
From 10 - 2000 Hz
10°C/ minute max. allowable
10°C/ minute max. allowable
5 sec. dwell
-20
-20
50
20
90
100
260
-20
-20
50
20
90
100
260
g
g
o
Switch Model
→
Contact Form
→
Conditions
Any DC combination of V & A not
to exceed their individual max.‘s
DC or peak AC
DC or peak AC
DC or peak AC
w/ 0.5 V & 10mA
Measured w/ 0.5 V & 50 mA ,
1.5 ms after closure
100 volts applied
Voltage applied for 60 sec. min.
Measured w/ 50 % overdrive
Measured w/ no coil suppression
at 10 kHz across contact
Switch 66
Form A
Switch 85
Form A
Min. Typ. Max. Min. Typ. Max. Unit
10
200
0.5
1.25
150
200
10
10
*
225 *
100
400
1.0
2.5
150
200
10
10
4000
W
V
A
A
mΩ
mΩ
Ω
VDC
0.5
0.1
0.2
0.2
1.0
0.1
ms
ms
pF
C
C
C
o
o
Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive
switch.
* Insulation resistance of 10
12
and breakdown voltage of 480 VDC is available.
These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if
more detail is required.
www.meder.com
299