EEWORLDEEWORLDEEWORLD

Part Number

Search

P2Z9ACA900W

Description
Phase Control Modules (345-800 Amperes/400-3000 Volts)
File Size83KB,6 Pages
ManufacturerPOWEREX
Websitehttp://www.pwrx.com/Home.aspx
Download Datasheet View All

P2Z9ACA900W Overview

Phase Control Modules (345-800 Amperes/400-3000 Volts)

POW-R-BRIK™
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Phase Control Modules
345-800 Amperes/400-3000 Volts
OUTLINE DRAWING
MARKING: DEVICE
AND DIRECTION
ACCORDING TO CIRCUIT
CONFIGURATION CHART
C
G TAPPED HOLE
x 0.50 DEEP
TYP. 3 PLACES
MARKING: K1
AI/K2 (ANODE)/(CATHODE),
AND A2 (ANODE) AS SHOWN
A2
D
B
L TYP. 4 PLACES
C
L
K1
C
L
X2
F
A
MARKING: STYLE NO. WITH DATE
CODE & MFG. LOCATION CODE
(CUSTOMER PART NO. OPTIONAL)
F
E Ø THRU HOLE TYP. 4 PLACES
(FOR TYP. 1/4-20 SOCKET HD. SCR.)
(& BELLEVILLE SPRING WASHER)
GATE (WHITE) & CATHODE
(RED) LEADS 12.5" LONG
WITH 0.375" LONG
STRIPPED ENDS
SENSOR (WHITE) LEADS
12.5
±0.5"
LONG WITH
0.375" IN LONG STRIPED ENDS
POW-R-BRIK™
Phase Control Modules
345-800 Amperes/400-3000 Volts
J
H
K
CASE ANODIZED PER
MIL-A-8625, TYPE II
C
L
THIS SURFACE
MUST BE PROTECTED
AND NOT DAMAGED
Outline Drawing
Z7A Outline
Dimension
A
B
C
D
E
F
G
Inches
6.30
3.02
3.15
2.47
0.328 Dia.
1.83
5/16-18
UNC-2B
H
J
K
L
1.27
2.09
2.25
0.56
Millimeters
153.16
76.70
80.01
62.73
Dia. 8.33
46.48
5/16-18
UNC-2B
32.25
53.08
57.15
14.22
Z9A Outline
Dimension
A
B
C
D
E
F
G
Inches
7.50
3.70
3.15
3.15
0.328 Dia.
2.03
3/8-16
UNC-2B
H
J
K
L
1.51
2.52
2.75
0.56
Millimeters
190.50
93.98
80.01
80.01
Dia. 8.33
51.56
3/8-16
UNC-2B
38.35
64.00
69.85
14.22
Description:
Powerex POW-R-BRIK™ Modules
are designed for medium and high
current power control applications.
POW-R-BRIK™ Modules feature
an electrically isolated package
that simplifies system packaging,
installation and cooling.
POW-R-BRIK™ Modules utilize
Compression Bonded
Encapsulation (CBE) mounting
and double side cooling of the
semiconductor elements. The Z7A
outline POW-R-BRIK™ uses
33mm or 38mm elements and the
Z9A outline POW-R-BRIK™ uses
50mm elements. Standard circuit
configurations include Dual SCR,
Dual Diode, SCR/Diode, and
Diode/SCR. Additional circuit con-
figurations, e.g. Single Element,
Common Cathode, Common
Anode, and special element types,
e.g. Fast Switch SCRs, Fast
Recovery Diodes, GTOs, and
Transistors are available.
Features:
Electrically Isolated Packaging
Anodized Aluminum Housing
Internal Copper Contacting
Gold Element Contacting
Internal Temperature Sensor
Compression Element
Contacting
Applications:
Mounting Bolt (E) Torque Limit is 11 ft.-lb.
Electrical terminal (G) torque limit is 11 ft.-lb. for type
Z7A and 20 ft.-lb. for Z9A.
Apply a thin coating of thermal joint compound to heat
sink surface prior to module mounting.
Module weights: Z7A weighs 6 lbs. while the Z9A module
weighs 11 lbs.
If incoming tests are done for isolation voltage, the volt-
age should be applied in a slow manner rather than
abruptly imposed on the device. The voltage should be
applied between the top terminals, which must be shorted
together, and the metal case.
The metal case is anodized and provides added voltage
isolation capability if not damaged: factory hi-pot test is
achieved without the benefit of the anodized coating.
Ordering Information:
Select the complete thirteen digit
module part number you desire
from the Configuration Reference
Description.
Example: P3Z7ACT700W16 is a
1600 Volt, 375 Ampere Average,
Dual SCR POW-R-BRIK™ Module
with the standard thermistor.
AC Motor Starters
DC Motor Controls
Resistance Welding Controls
Mining Power Centers
High Voltage Motor Starters
Transportation Systems
P-1
Could you please give me some advice, can the following circuit be established? What is the reason why it cannot be established?
[img]http://images22.51.com/6000/tf_digital/87d285dd879de62385f561622f9df420.jpg[/img] The circuit is drawn by myself, and my personal analysis is as follows. I hope you can correct me if there are an...
xiong8707 RF/Wirelessly
Weekly highlights: 2018.11.26-12.2
[size=4]Hi, everyone! Welcome to the post. It’s time to review the highlights of the week! Without further ado, come and read the post! [/size] [size=4] [/size] [size=4][b][color=#ff0000]Recommended e...
okhxyyo Robotics Development
[Help] LCD cannot be written
我想写一个计算的东西东西 但是不能显示//****************************************************************************** //MSP-FET430P440 Demo - Timer_A Toggle P5.1, CCR0 upmode ISR, 32kHz ACLK// //Description; Toggle P5....
liyang203 Microcontroller MCU
Selection of winning works of the 5th National Undergraduate Electronic Design Competition (2001)
[i=s] This post was last edited by paulhyde on 2014-9-15 09:23 [/i] I have read it myself, it may be useful, please download and have a look if you need it. =============== There is already software t...
yongzone Electronics Design Contest
Please help me with the BUS fault when reading and writing EEPROM of STM32 microcontroller
The STM32 microcontroller's EEPROM read and write has a BUS fault. Does anyone have experience with similar applications?...
qushaobo stm32/stm8
Please support 64-bit Xilinx ISE software
I have installed many but they can't run...
糊涂大发 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1909  1577  1002  32  1840  39  32  21  1  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号