Bulletin I2158 rev. A 08/02
SAFE
IR
Series
25ETS..S
INPUT RECTIFIER DIODE
Description/Features
The 25ETS.. rectifier
SAFE
IR
series has been
optimized for very low forward voltage drop, with
moderate leakage. The glass passivation
technology used has reliable operation up to 150°C
junction temperature.
Typical applications are in input rectification and
these products are designed to be used with
International Rectifier Switches and Output
Rectifiers which are available in identical package
outlines.
V
F
I
FSM
< 1V @ 10A
= 300A
V
RRM
800 - 1200V
Output Current in Typical Applications
Single-phase Bridge
Capacitive input filter T
A
= 55°C, T
J
= 125°C,
common heatsink of 1°C/W
20
Three-phase Bridge
23
Units
A
Major Ratings and Characteristics
Characteristics
I
F(AV)
Sinusoidal
waveform
V
RRM
Range (*)
I
FSM
V
F
T
J
@ 10 A, T
J
= 25°C
Package Outline
Units
A
V
A
V
°C
25ETS..
25
800 - 1200
300
1.0
- 40 to 150
D
2
Pak (SMD-220)
(*)
for higher voltage up to 1600V contact factory
www.irf.com
1
25ETS..S
SAFE
IR
Series
Bulletin I2158 rev. A 08/02
Voltage Ratings
V
RRM
, maximum
Part Number
peak reverse voltage
V
800
1200
V
RSM
, maximum non repetitive
peak reverse voltage
V
900
1300
I
RRM
150°C
mA
1
25ETS08S
25ETS12S
Provide terminal coating for voltages above 1200V
Absolute Maximum Ratings
Parameters
I
F(AV)
Max. Average Forward Current
I
FSM
I t
2
25ETS..S
25
250
300
316
442
Units
A
A
A
2
s
A
2
√s
Conditions
@ T
C
= 106° C, 180° conduction half sine wave
10ms Sine pulse, rated V
RRM
applied
10ms Sine pulse, no voltage reapplied
10ms Sine pulse, rated V
RRM
applied
10ms Sine pulse, no voltage reapplied
t = 0.1 to 10ms, no voltage reapplied
Max. Peak One Cycle Non-Repetitive
Surge Current
Max. I t for fusing
2
I
2
√t
Max. I
2
√t
for fusing
4420
Electrical Specifications
Parameters
V
FM
r
t
I
RM
Max. Forward Voltage Drop
Forward slope resistance
25ETS..S
1.14
9.62
0.87
0.1
1.0
Units
V
mΩ
V
mA
Conditions
@ 25A, T
J
= 25°C
T
J
= 150°C
T
J
= 25 °C
T
J
= 150 °C
V
F(TO)
Threshold voltage
Max. Reverse Leakage Current
V
R
= rated V
RRM
Thermal-Mechanical Specifications
Parameters
T
J
T
stg
Max. Junction Temperature Range
Max. Storage Temperature Range
to Case
Max. Thermal Resistance Junction
to Ambient
R
thCS
Typ. Thermal Resistance Case
to Heatsink
wt
T
Approximate Weight
Mounting Torque
Case Style
Min.
Max.
0.5
2 (0.07)
6 (5)
12 (10)
°C/W
g (oz.)
Kg-cm
(Ibf-in)
Mounting surface, smooth and greased
25ETS..S
- 40 to 150
- 40 to 150
0.9
62
Units
°C
°C
°C/W
°C/W
Conditions
R
thJC
Max. Thermal Resistance Junction
R
thJA
DC operation
D
2
Pak (SMD-220)
2
www.irf.com
25ETS..S
SAFE
IR
Series
Bulletin I2158 08/02
Maximum Allowable Case Temperature (°C)
150
140
130
Maximum Allowable Case Temperature (°C)
25ETS..S Series
R
thJC
(DC) = 0.9 K/W
150
140
130
120
110
30˚
25ETS..S Series
RthJC (DC) = 0.9 K/W
Conduction Angle
Conduction Period
120
110
100
90
80
0
5
10
15
20
25
30
Average Forward Current (A)
Fig. 1 - Current Rating Characteristics
30˚
60˚
90˚
120˚
180˚
60˚
100
90
0
5
90˚
120˚
180˚
DC
10 15 20 25 30 35 40
Average Forward Current (A)
Fig. 2 - Current Rating Characteristics
Maximum Average Forward Power Loss (W)
Maximum Average Forward Power Loss (W)
40
35
30
25
20
15
10
5
0
0
180˚
120˚
90˚
60˚
30˚
RMS Limit
60
50
40
30
DC
180˚
120˚
90˚
60˚
30˚
Conduction Angle
RMS Limit
20
10
0
0
10
20
Conduction Period
25ETS..S Series
T
J
= 150˚C
25ETS..S Series
T
J
= 150˚C
5
10
15
20
25
30
30
40
Average Forward Current (A)
Fig. 3 - Forward Power Loss Characteristics
Peak Half Sine Wave Forward Current (A)
Peak Half Sine Wave Forward Current (A)
Average Forward Current (A)
Fig. 4 - Forward Power Loss Characteristics
300
200
At Any Rated Load Condition And With
Rated V
Applied Following Surge.
RRM
Initial T
J
= 150˚C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
300
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Initial T
J
= 150˚C
No Voltage Reapplied
Rated V
Reapplied
RRM
200
100
100
25ETS..S Series
25ETS..S Series
0
1
10
100
Number Of Equal Amplitude Half Cycle Current Pulsed (N)
0
0.01
0.1
1
10
Fig. 5 - Maximum Non-Repetitive Surge Current
Pulse Train Duration (s)
Fig. 6 - Maximum Non-Repetitive Surge Current
www.irf.com
3
25ETS..S
SAFE
IR
Series
Bulletin I2158 rev. A 08/02
1000
T
J
= 25˚C
Instantaneous Forward Current (A)
100
T = 150˚C
J
10
25ETS.. Series
1
0
1
2
3
4
5
Instantaneous Forward Voltage (V)
Fig. 7 - Forward Voltage Drop Characteristics
1
T
ransient T
hermal Impedance Z
thJC
W)
(˚C/
D = 0.50
D = 0.33
D = 0.25
D = 0.17
D = 0.08
Steady State Value
(DC Operation)
Single Pulse
0.1
25ETS. .Series
0.01
0.0001
0.001
0.01
0.1
1
10
100
Square Wave Pulse Duration (s)
Fig. 8 - Thermal Impedance Z
thJC
Characteristics
4
www.irf.com
25ETS..S
SAFE
IR
Series
Bulletin I2158 08/02
Outline Table
4.69 (0.18)
4.20 (0.16)
1.32 (0.05)
10.16 (0.40)
REF.
6.47 (0.25)
15.49 (0.61)
1.22 (0.05)
93°
6.18 (0.24)
14.73 (0.58)
2.61 (0.10)
2.32 (0.09)
8.89 (0.35)
5.28 (0.21)
4.78 (0.19)
0.55 (0.02)
0.46 (0.02)
3X
1.40 (0.055)
REF.
0.93 (0.37)
0.69 (0.27)
1.14 (0.045)
2X
MINIMUM RECOMMENDED FOOTPRINT
11.43 (0.45)
1
3
4.57 (0.18)
4.32 (0.17)
2
0.61 (0.02) MAX.
5.08 (0.20) REF.
8.89 (0.35)
17.78 (0.70)
3.81 (0.15)
2.08 (0.08)
2X
2.54 (0.10)
2X
Dimensions in millimeters and inches
Marking Information
THIS IS A 25ETS12S
LOT CODE 8024
ASSEMBLED ON WW 02, 2000
IN THE ASSEMBLY LINE "L"
INTERNATIONAL
RECTIFIER
LOGO
ASSEMBLY
LOT CODE
PART NUMBER
25ETS12S
DATE CODE
YEAR 0 = 2000
WEEK 02
LINE L
www.irf.com