3-Phase AC Filters / DC Filters
https://www.schurter.com /PG80
FMAC SINE DCL
Sine wave output filter with a voltage dc link
Approvals and Compliances
Description
- Design corresponding to UL 1283, CSA 22.2 No. 8, IEC/EN60939
- Enhancement of the system efficiency
Applications
- Optimized for long motor cables (up to 1000 m) and operation under
full load
- Equipped with voltage connection to converter dc link circuit for best
results
- Frequency converters in uninterruptible power supplies, elevators, he-
ating-, ventilating- and air conditioning-systems, traction and conveyer
systems
- Cost saving technologie, increase of motor life time, deployment of
flexible lightweight unshielded instead of expensive shielded motor ca-
bles, reduced fitting work
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Detailed request for product, Microsite
Technical Data
Rated Current
Rated voltage
Approval for
Overload Current
Dielectric Strength
4 - 16 A @ Ta 40 °C
500/288 VAC; 50/60 Hz
4 - 16 A @ Ta °C / 500/288 VAC; 50 Hz
1.5 x Ir for 1 minute, per hour
500/288 VAC:
1.1 kVDC between L-L
2.5 kVDC between L-PE
Test voltage (2 sec)
16 - 24 kg
Metal
UL 94V-2
Mounting
Terminal
Operating Temperature
Climatic Category
Degree of Protection
Protection Class
Screw-on mounting on chassis, from
top
Screw clamps
-25 °C to 100 °C
25/100/21 acc. to IEC 60068-1
IP 20 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Weight
Material: Housing
Sealing Compound
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Standard
IEC/UL 60950
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
EMC Products
1
FMAC SINE DCL
Diagrams
3-Phase AC Filters / DC Filters
https://www.schurter.com /PG80
F1
F2
F3
A)
B)
3
3
1)
2)
3)
4)
M
3
5)
A)
U
B)
U
I
L1 L2 L3
PE
I
Note:
The inverter switching frequency must lie within the range from 2 to 20kHz. A
switching frequency below or above the mentioned range will result in poor perfor-
mances.
Sine wave output filters with dc-link produce leakage currents. These leakage cur-
rents could, in combination with certain OEM inverter types, disturb overall system
performance, causing a "over current or short to earth" error message on the inver-
ter. For such cases Schurter suggests the following three solutions or a combination
of each:
1) Increasing the switching frequency of the inverter (drawback: increased power
loss in the inverter)
2) Activating the low leakage sine wave output filter operation mode by removing
the factory set detachable screw (drawback: light increase of the leakage current in
the motor)
3) Connecting a ground wire choke type DEH in the inverters earth connection
(drawback: additional component)
1) Inverter 2) Ground choke 3) DC-Link 4) Sine wave output filter 5) Motor
All Variants
Rated Current
[A]
8
4
12
16
Rated voltage
[VAC]
500/288
500/288
500/288
500/288
Switching fre-
quency
[kHz]
2...20
2...20
2...20
2...20
Motor frequency
[Hz]
0...200
0...200
0...200
0...200
Rated motor
power
[kW]
3.0
1.5
5.5
7.5
Motor cable
lenght
[m]
<= 1000
<= 1000
<= 1000
<= 1000
DC resi-
stance
[mΩ]
220
450
140
110
Total power loss
[W]
14
8
20
28
Weight
[kg]
16 kg
13 kg
20 kg
24 kg
IB
2G
2H
2I
FMAC-0SIB-0862
FMAC-0S2G-0462
FMAC-0S2H-1262
FMAC-0S2I-1662
Housings
Order Number
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit
1 Pcs
4
EMC Products
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
07.12.2017