Compliance to EN55022 (CISPR22) Class A with external components (please refer to "EMC Suggestion Circuit")
Compliance to EN61000-4-2,3,4,5,6,8; EN55024, light industry level, criteria A
Aluminum
1000K hrs typ. MIL-HDBK-217F (25 )
57.9*61*12.7mm (2.28"*2.40"*0.5") (L*W*H)
92g
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 1uf ceramic & 10uf tantalum capacitor across output.
3. The power supply need to connect "+Vout" to "+R.S" and "-Vout" to "-R.S".
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
File Name:MHB75-SPEC 2011-09-08
75W DC-DC Half-Brick Regulated Single Output Converter
Mechanical Specification
All Dimensions In Inches [mm]
Tolerance Inches: X.XX= 0.02 , X.XXX= 0.010
Millimeters: X.X= 0.5 , X.XX= 0.25
MHB75
series
Unit:inch[mm]
0.18 min. 0.50
[4.6] [12.7]
Mounting Inserts M3*0.5
BOTTOM VIEW
R1.50
3
6
7
1.40
[35.56]
2.40
[61.0]
2.00
[50.8]
0.60
[15.24]
2
8
1
9
0.04
[1.02]
4
5
0.08
[2.03]
1.90
[48.3]
2.28
[57.9]
SIDE VIEW
Pin No. Assignment
Pin No.
1
2
3
Assignment
+Vin
R.C.
Case
Pin No.
4
5
6
Assignment
-Vin
-Vout
-R.S.
Pin No.
7
8
9
Assignment
Trim
+R.S.
+Vout
Remote ON/OFF Control
The MHB75 series allow the user to switch the power ON and OFF electronically by their remote ON/OFF feature.
The MHB75 series are available with "Positive Logic" (standard) or "Negative Logic" (option).
This is a list of things to note in logic design. Errors caused by this often make the design unreliable or slow. In order to improve design performance and increase reliability at speed, you must mak...
Let's share good resources. Haha, I think it's good. I'd like to give it a thumbs up [url=http://www.shpnet.cn/index.php?fromuid=94385]China Video Tutorial Base[/url]...
I want to create a file with system time as the name. Here is my code. There is a problem that I can't get over. The operating environment is wince5.0, developed with VS2005. Please give me some advic...
Abstract: The MAX1679/MAX1736 adopts a novel charge termination control scheme to relax the power supply requirements, use fewer external components, and reduce the overall cost of lithium battery cha...