Description
Power Line Filters AC 1-250 / DC250 10A 12.5 uA/ 25 uA max
CategoryAnalog mixed-signal IC    filter   
File Size340KB,3 Pages
ManufacturerCosel
Environmental Compliance
Download Datasheet Parametric View All

NAM-10-101 Online Shopping

Suppliers Part Number Price MOQ In stock  
NAM-10-101 - - View Buy Now

NAM-10-101 Overview

Power Line Filters AC 1-250 / DC250 10A 12.5 uA/ 25 uA max

NAM-10-101 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCosel
Reach Compliance Codeunknown
CertificationUL; CSA; VDE; ENEC-10
filter typeSINGLE PHASE EMI FILTER
high41 mm
high potential2500 V
Maximum leakage current0.025 mA
length92 mm
Manufacturer's serial numberNAM
Installation typeCHASSIS MOUNT
working frequency60Hz Hz
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
physical sizeL92.0XB53.0XH41.0 (mm)/L3.622XB2.087XH1.614 (inch)
Rated current10 A
Rated voltage250 V
Low leakage current type
Ordering information
NAM series
NAM -10 -000
1
2
3
4
-O
R
1
Model Name
2
Rated Current
3
Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
000
101
221
331
471
*
Line to ground
Leakage Current
capacitor
(Input 125/250V 60Hz)
(nominal value)
A/ 10 A max
Not Provided
5
100pF
12.5 A/ 25 A max
A/ 50 A max
220pF
25
330pF
37.5 A/ 75 A max
A/100 A max
470pF
50
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4
Options
D :DIN rail installation type
The terminal cover is retracted inside the unit
DIN rail installation type is option
*
The dimensions change when the option is set.
Refer to External view.
Features of NAM series
Low leakage current type
-
Single Phase 250 VAC
-
Push down type terminal block
Specifications
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Items
Rated Voltage[V]
Rated Current[A]
Test Voltage (Terminal-Mounting Plate)
Isolation Resistance (Terminal-Mounting Plate)
Leakage current 125/250V 60Hz
Voltage drop
Safety agency approval temperatures
Operating temperature
Operating humidity
Storage temperature/humidity
Vibration
Impact
Safety agency approvals
Case size (without projection) /Weight
NAM-04-000
4
NAM-06-000
6
NAM-10-000
10
NAM-16-000
16
NAM-20-000
20
NAM-30-000
30
AC 1f 250 / DC250
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
500 VDC 100MW min at room temperature and humidity
5 A/10 A max
1.0V max
-25 to +85C (Refer to Derating Curve)
-40 to +85C (Refer to Derating Curve)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
10 to 55Hz, 19.6m/s
2
(2G), 3min. Period, 1hour each X, Y and Z axis
196.1m/s
2
(20G), 11ms Once each X, Y and Z axis
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
53X41X92 mm [2.09X1.61X3.62 inches] (WXHXD) /300g max (Option : -D refer to external view)
Circuit Diagram
Case
Derating Curve
100
3
LOAD
4
Load Factor [%]
80
60
40
20
0
-40
CY : Line to ground capacitor
: Mounting Plate
-30
-20
40
50 55 60
70
80
90
1
LINE
2
CY
CY
Ambient Temperature [C]
NF-37
[Award Ceremony] Xilinx Industrial and Medical Quiz Winners Announced
Thank you for your active participation in this event. According to your answers, the following 10 netizens were selected to receive USB heating coasters. [font=楷体,楷体_GB2312][size=5][color=black][b]So...
EEWORLD社区 FPGA/CPLD
How to make a negative power supply for MAX660?
I found the circuit from the datasheet, but the output is 0V. I don't know why. Is it necessary to connect a crystal oscillator? When I soldered the PCB board, pins 7 and 6 were not connected....
20103242 Power technology
Power Supply for Operational Amplifiers
Is the power supply of the operational amplifier within a certain range, such as 5-15V?...
lsspb Analog electronics
Great opportunity!! Recommended to join Huawei
Xi'an Huawei Research Institute has started a new round of recruitment. Major: Computer, Communication, Electronics, Physics and other engineering majors (this time the major requirements are not very...
mcuer Embedded System
How to write data acquisition program when AD chip performs high-speed data acquisition
I wrote a data acquisition program and I saved the data directly into a TXT text file. But the number of points is wrong when acquiring at 40KHZ. Can an expert tell me how to achieve high-speed data a...
zhangy11 Embedded System
Does Microsoft have Windows CE engineer certification?
Just as the title!...
a8719978 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1822  1350  295  1288  1819  37  28  6  26  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号