BL600
CHARGERS
B L 6 0 0 L I T H I U M - I O N FA S T
B L 6 0 0 L I T H I U M - I O N FA S T
CHARGERS
•
•
•
•
•
•
•
•
•
•
•
BVL
Thermistor
Required
Number
of Cells
Volts
DC
Fast Charge
Maximum
**Current Amps
Ault Part No.
100-250 VAC
In Case IEC 320
LED Indicators
Charges Li-Ion Batteries
Optimizes Battery Life
Meets Safety Agency Requirements
Complies with EMI-RFI Regulations
Impact Resistant Polycarbonate Enclosure
Private Label Marking Available
3 Year Warranty
Modified and Custom Designs Also
Available
BL600-*-02-170-00-03K
BL600-*-03-314-00-03K
BL600-*-04-100-00-03K
BL600-*-02-170-00-21K
BL600-*-03-314-00-21K
BL600-*-04-100-00-21K
No
No
No
Yes
Yes
Yes
2
3
4
2
3
4
8.4
12.6
16.8
8.4
12.6
16.8
1.7
1.4
1.0
1.7
1.4
1.0
**Available Current Rating
2 Cell
3 Cell
4 Cell
0.10 to 1.70A
0.10 to 1.40A
0.10 to 1.00A
Ault Part No. Key
Ault Part No. Key
BL600 *
Product
Family
Name
02
170
00
03
K
Denotes
Number
Safety Timer
of Cells
(with or without
thermistors)
Fast Charge
Denotes standard
Current/Amps or custom
requirements
Connector Manufacturing
Location
A U LT I N C O R P O R AT E D
7105 Northland Terrace
|
Minneapolis, Minnesota 55428
|
USATEL (1) 763-592-1900
FAX (1) 763-592-1911
|
E-MAIL info@aultinc.com
|
WEB www.aultinc.com
© Copyright 2002 Ault Inc.
BL600
CHARGERS
Input
Voltage
Line Frequency
Current
Protection
B L 6 0 0 L I T H I U M - I O N FA S T
Environmental
100-250 VAC -10%, +6%
47 - 63 Hz
0.80A - 0.35A (lower with higher voltage)
Internal primary current fuse
Inrush limiting
Short circuit protection
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Cooling
0º to 40º C with no derating
-30º to +85º C
5% to 95% non-condensing
0-10,000 feet
Convectional - non vented case
Electrical
Topology
Dielectric Withstand
EMI
CE
MTBF
MTBF
Protection
Switching - DC battery charger
3000 VAC, 4243 VDC primary- secondary
Complies with EMC Directives
CE Compliant
100,000 calculated hours
100,000 calculated hours
Output current limiting
Short circuit protection
Mechanical
Case and Dimensions
LP6 - Desktop
4.22L x 2.60W x 1.53H (in)
107L x 66W x 38H (mm)
Black 94V0 polycarbonate
8 ounces, 224 grams (excluding cord)
6 ft., 2 conductor, 20 AWG, Ault #3
connector and 6 ft., 3 conductor, 20
AWG Ault #21 connector. Other con-
nectors are also available.
Case Material
Weight
Cords and Connectors
Safety Approvals
Agency Listings
CULus1950; TUV EN60950, CE
Charger Timers Available for 2, 3, and 4 Cell
(*from pg. 1)
1 = 3 hr/no thermistor
2 = 6 hr/no thermistor
3 = 9 hr/no thermistor
5 = 3hr hr/ thermistor
6 = 6hr hr/ thermistor
7 = 9hr hr/ thermistor
Input Configuration
Please specify the Charger Timer Code in your order
IEC320
w/ground
C14
(F)
Connectors
Configuration: In Case IEC320 with ground
LED Indicators
80%
No
Charge Completion Abnormal Battery
ON
ON
OFF
ON
Blink
Blink
OFF
OFF
Charge
Led1 (Yellow) ON
Led2 (Green)
OFF
Other Connectors are available by special order
A U LT I N C O R P O R AT E D
7105 Northland Terrace
|
Minneapolis, Minnesota 55428
|
USATEL (1) 763-592-1900
FAX (1) 763-592-1911
|
E-MAIL info@aultinc.com
|
WEB www.aultinc.com
© Copyright 2002 Ault Inc.