Industrial and process control, distributed power, medical, ATE, communications,
defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to -IN voltage
PC to -IN voltage
PR to -IN voltage
SC to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +53
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24C12T100BL2
24C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
V
OUT
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
B
Output Power
P
OUT
75W, 50W
125W, 100W, 50W
100W
150W, 100W, 50W
150W, 100W, 50W
150W,100W, 50W
150W, 100W, 50W
100W, 50W
150W, 100W, 50W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
24V Micro Family
Page 1 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Modules will operate to 16V
IN
after startup at >17.9V.
Below 18V, available power is reduced to 75% of max
rating.
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% /°C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Micro Family
Page 2 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20 ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30
Ω,
<30 pF
PC current = 1.0 mA
PC voltage = 5.5 V
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Micro Family
Page 3 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 75W (e.g. S24C3V3C75BL, V24C3V3C75BL)
Parameter
Min
84.6
80.0
4.14
Efficiency
S24C3V3C75BL (enhanced efficiency)
V24C3V3C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Typ
86.2
81.6
140
4.3
4
±0.02
26.1
26.1
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
23.1
15.8
175
4.46
6
±0.4
22.72
30.7
30.7
mV
Volts
Watts
%
Amps
Amps
Amps
3.3V
OUT
, 50W (e.g. S24C3V3C50BL, V24C3V3C50BL)
Parameter
Efficiency
S24C3V3C50BL (enhanced efficiency)
V24C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.6
75.0
4.14
Typ
84.0
79.2
240
4.3
1.6
±0.02
17.5
17.5
Max
Unit
%
300
4.46
3
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 125W (e.g. S24C5C125BL, V24C5C125BL)
Parameter
Efficiency
S24C5C125BL (enhanced efficiency)
V24C5C125BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
83.0
6.0
Typ
86.5
84.5
150
6.25
4.3
±0.02
28.8
28.8
Max
Unit
%
188
6.5
5.3
±0.2
25.0
33.8
33.8
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p Nominal input full load 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250mV
0.0
25.5
17.5
5V
OUT
, 100W (e.g. S24C5C100BL, V24C5C100BL)
Parameter
Efficiency
S24C5C100BL (enhanced efficiency)
V24C5C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.9
84.0
6.03
Typ
87.4
85.7
100
6.25
3.2
±0.02
23
23
Max
Unit
%
125
6.47
4.8
±0.2
20
27
27
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
2
24V Micro Family
Page 4 of 15
Rev 6.5
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. S24C5C50BL, V24C5C50BL)
Parameter
Efficiency
S24C5C50BL (enhanced efficiency)
V24C5C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
83.0
6.03
Typ
87.8
84.5
80
6.25
1.3
±0.02
11.5
11.5
Max
Unit
%
100
6.47
2.1
±0.2
10
13.5
13.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
2
8V
OUT
, 100W (e.g. S24C8C100BL, V24C8C100BL)
Parameter
Efficiency
S24C8C100BL (enhanced efficiency)
V24C8C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
85.0
9.36
Typ
89.0
86.4
145
9.7
3
±0.02
14.4
14.4
Max
Unit
%
182
10.1
3.4
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 150W (e.g. S24C12C150BL, V24C12C150BL)
Parameter
Efficiency
S24C12C150BL (enhanced efficiency)
V24C12C150BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.0
87.5
13.8
Typ
89.5
88.8
170
14.3
3.7
±0.02
14.4
14.4
Max
Unit
%
212
14.8
4.5
±0.2
12.5
16.9
16.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p Nominal input full load 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.8
8.8
12V
OUT
, 100W (e.g. S24C12C100BL, V24C12C100BL)
Parameter
Efficiency
S24C12C100BL (enhanced efficiency)
V24C12C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.7
87.0
13.7
Typ
90.2
88.4
209
14.3
4.4
±0.02
9.59
9.59
Max
Unit
%
262
14.9
6.1
±0.2
8.33
10.9
10.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
1. If I use an external crystal oscillator, how do I set the software? I use 32.768khz, how many M can it become? If I use the default state, how many will it be when it works?2. When programming C430...
[size=4][color=#000000] Microcontrollers were born in 1971 and have gone through three stages: SCM, MCU, and SoC. Early SCM microcontrollers were all 8-bit or 4-bit. The most successful one was INTEL'...
I would like to ask everyone, is there anyone who can use proteus, please leave me your QQ number, or add my QQ directly: 605256075, when adding, please indicate that you can use proteus, thank you!!!...
[b]The law of correlation is also called the law of universal connection. Its main contents include the following three aspects: [/b] [b]First, the various parts, elements, and links within any thing ...
I am using F149 chips. Are the compilation environment installers fet_r300u.exe and FET_R301.exe? It seems that the CD I bought does not indicate this version, but do I have the one I was given? Can t...
Hello everyone! I'm working on the DM9000 driver under wince5.0 and I'm having some problems! I added debugging information to the driver and found that there was a problem with my interrupt request! ...
The intelligent driving community has its own rhythm. Some are busy pushing new versions and focusing on R&D, others are busy with publicity and promotion, and still others are immersed in mass pro...[Details]
Abstract:
With the increasing complexity of smart vehicle electrical and electronic architectures, the full lifecycle management of vehicle electronic control components faces multiple challe...[Details]
New energy vehicles are increasingly popular with consumers due to policies and energy conservation. Once you've purchased your vehicle, maintenance is essential. However, due to the different powe...[Details]
The digital TV set-top box consists of a tuner, QAM demodulator, TS demultiplexer, MPEG-2 decoder, PAUNTSC video encoder, embedded CPU system and peripheral interfaces, CA module, and uplink data m...[Details]
According to Nikkei, a survey found that global electric vehicle battery supply is expected to reach more than three times the required quantity due to
cooling
demand for electric vehicles,...[Details]
Tiantai Robot's official Weibo account announced on the evening of August 20 that Tiantai Robot Co., Ltd., together with strategic partners including Shandong Future Robot Technology Co., Ltd., Sha...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
Preface
Low-voltage motors are widely used in nonferrous metallurgical plants. Their abnormal operation not only impacts normal production but can also threaten human life. Therefore, providin...[Details]
A pure sine wave inverter has a good output waveform with very low distortion, and its output waveform is essentially the same as the AC waveform of the mains power grid. In fact, the AC power prov...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
High-definition media consumption is experiencing a dual growth: an increase in the number of consumers and a transition to higher-definition content. This growth is driven by increasingly widespre...[Details]
0 Introduction
DVI (Digital Visual Interface) is a hot topic in current digital display research and application. Video processing technologies for DVI output not only address issues such as h...[Details]
With the continuous development of ultrasonic technology, ultrasound has been widely used in fields such as inspection, cleaning, welding, and medical treatment, and has even found its way into tex...[Details]
Pure electric vehicles have experienced rapid growth in recent years, and many consumers now consider them as a top choice when purchasing a car. But do you know how to choose a satisfactory and sa...[Details]
According to foreign media reports, German chipmaker Infineon has recently completed the acquisition of Marvell Technology's automotive Ethernet business for a total transaction amount of US$2.5 bi...[Details]