V12
Specifications
INPUT SPECIFICATIONS:
Voltage …....………........….......................................................... 90~264Vac
Frequency …………………………………………………………..... 47 to 63Hz
Inrush Current ……………… Cold Start@25℃ ............. 50A max. @240Vac
Leakage Current ……………………………………..….…….…… 1mA Typical
CFM40/60 Series Derating Curve
Open Frame versions:
CFM40S050, 40S090, 60S033, 60S050, 60S090
100%
Rated Load(%)
75%
50%
25%
0%
0
10
20
30
40
50
Ambient Temperature(
o
C)
60
70
20LFM(Natural Convection)
OUTPUT SPECIFICATIONS:
Holdup Time …………………………..………………...… 8ms typ. @115Vac
Short Circuit Protection …………………..…… Hiccup Mode (Auto Recover)
Over Voltage Protection ………………………….. TVS Component to Clamp
Temperature Coefficient ……………………............................... ±0.05%/℃
GENERAL SPECIFICATIONS:
Isolation ………………………..……………..…… Input to Output = 4,242VDC
Operating Temperature ................................ 0 ~ 70℃(see Derating Curve)
Storage Temperature …………………………....….......…........ -20~85℃
Humidity ....................................................... 93% RH max. Non-Condensing
Cooling ………………………..………………………..... Natural Convection
Switching Frequency ……………………………….…….……. 66KHz Typical
MTBF …………….… MIL-HDBK-217F, GB, 25℃/115VAC … 200K hrs min.
Altitude ……………………..……………………………….…….……… 2000m
Dimensions:
CFM40/60 Open Frame ………… 4.000x2.000x1.200Inches (101.60x50.80x30.48mm)
CFM40/60 Covered …………. 4.606x2.441x1.5750Inches (117.00x62.00x40.00mm)
CFM40S120, 40S150, 40S240, 40S300, 40S360, 40S480
CFM60S120, 60S150, 60S240, 60S300, 60S360, 60S480
100%
Rated Load(%)
75%
50%
25%
0%
0
10
20
30
40
50
Ambient Temperature(
o
C)
60
70
20LFM(Natural Convection)
Weight ……………………………. CFM40/60: 170g/175g (0.38/0.39 Pounds)
CFM40/60 Covered: 210g/215g (0.46/0.47 Pounds)
SAFETY AND EMC:
Emission and Immunity …....…. EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61204-3, EN61000-6-1
Safety ……………………………….… IEC60950-1, EN60950-1, UL60950-1
Covered versions: CFM40/60XXX-CA
CFM40S120, 40S150, 40S240, 40S300, 40S360, 40S480
100%
Rated Load(%)
75%
50%
25%
0%
0
10
20
30
40
50
Ambient Temperature(
o
C)
60
70
20LFM(Natural Convection)
NOTE:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
2. Line regulation is measured from High Line to Low Line with full load.
3. Load regulation is measured from full to 10% load.
4. Input connector mates with Molex housing 09-50-3031 and Molex
2878 series crimp terminal.
5. Output connector mates with Molex housing 09-50-3041 and Molex
2878 series crimp terminal.
6. Safety approvals do not apply to the Covered versions, only to the Open-
Frame versions.
CFM40S033, CFM40S050, CFM60S033, CFM60S050
100%
Rated Load(%)
75%
50%
25%
0%
0
10
20
30
40
50
Ambient Temperature(
o
C)
60
70
20LFM(Natural Convection)
CFM40S090, 60S090, 60S120, 60S150, 60S240, 60S300
CFM60S360, 60S480
100%
Rated Load(%)
75%
50%
25%
0%
0
10
20
30
40
50
Ambient Temperature(
o
C)
60
70
20LFM(Natural Convection)
2