Off-line systems with auto-ranging or PFC front ends, industrial and process control,
distributed power, medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V300A12T500BL2
300A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
P
OUT
160W
264W, 200W
400W, 300W
400W, 300W
500W, 400W
500W, 400W
500W, 400W
500W, 400W
500W, 400W
500W, 400W
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= 2V
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48 =
48V
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
Finish
Pin Style
Tin/Lead
Blank:
Short
Tin/Lead
L:
Long
Gold
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
300V Maxi Family
Page 1 of 14
Rev 10.1
10/2017
300V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
147.4
378.7
174.6
152.8
393.8
412.6
1.2
Min
180
Typ
300
Max
375
400
178.2
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.4
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 9.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
300V Maxi Family
Page 2 of 14
Rev 10.1
10/2017
300V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
300V Maxi Family
Page 3 of 14
Rev 10.1
10/2017
300V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
, 160W (e.g. S300A2C160BL, V300A2C160BL)
Parameter
Efficiency
S300A2C160BL (enhanced efficiency)
V300A2C160BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
74.5
72.5
2.7
Typ
82.5
74
262
2.8
7.9
±0.02
92
92
Max
Unit
%
327
2.9
8.1
±0.2
80
112
112
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 264W (e.g. S300A3V3C264BL, V300A3V3C264BL)
Parameter
Efficiency
S300A3V3C264BL (enhanced efficiency)
V300A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.0
80.0
4.14
Typ
84.5
81.2
288
4.3
8.1
±0.02
92
92
Max
Unit
%
360
4.46
9.4
±0.2
80
112
112
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S300A3V3C200BL, V300A3V3C200BL)
Parameter
Efficiency
S300A3V3C200BL (enhanced efficiency)
V300A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
80.5
78.1
4.14
Typ
84.5
79.6
80
4.3
6.2
±0.02
69.7
69.7
Max
Unit
%
100
4.46
12
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S300A5C400BL, V300A5C400BL)
Parameter
Efficiency
S300A5C400BL (enhanced efficiency)
V300A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.8
81.5
6.03
Typ
86.5
83
316
6.25
6.2
±0.02
92
92
Max
Unit
%
395
6.47
9.3
±0.2
80
112
112
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
300V Maxi Family
Page 4 of 14
Rev 10.1
10/2017
300V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 300W (e.g. S300A5C300BL, V300A5C300BL)
Parameter
Efficiency
S300A5C300BL (enhanced efficiency)
V300A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
83.2
6.03
Typ
86.5
84.2
150
6.25
12.0
±0.02
69
69
Max
Unit
%
188
6.47
13.2
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
8V
OUT
, 400W (e.g. S300A8C400BL, V300A8C400BL)
Parameter
Efficiency
S300A8C400BL (enhanced efficiency)
V300A8C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.7
82.5
9.36
Typ
87.0
83.8
320
9.7
14.6
±0.02
57.5
57.5
Max
Unit
%
400
10.1
16
±0.2
50
67.5
67.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
8V
OUT
, 300W (e.g. S300A8C300BL, V300A8C300BL)
Parameter
Efficiency
S300A8C300BL (enhanced efficiency)
V300A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
82
9.36
Typ
87.0
84.8
250
9.7
8.9
±0.02
43.1
43.1
Max
Unit
%
313
10.1
10
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. S300A12C500BL, V300A12C500BL)
Parameter
Efficiency
S300A12C500BL (enhanced efficiency)
V300A12C500BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.6
85.5
13.7
Typ
88.0
86.7
280
14.3
12.2
±0.02
48
48
Max
Unit
%
350
14.9
13.2
±0.2
41.6
60.5
60.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Thank you SOSO for sending me the book "MCU Engineer's Refining". I read it quickly and was touched. This book may be aimed at students or newcomers to the workplace. For engineers who often use MSP43...
When I got this chip today, I couldn't wait to pick up my project master ZIGBEE to tune it and join the networking experiment to see how the storage effect is. It took two days for the two of us to fi...
I found some drivers for ssd1289 on the Internet and wanted to port them to LM3S9B92. The program was to light up the TFT screen, but it didn't work.I need some help from an expert...#include "hw_ints...
[i=s]This post was last edited by Diguapatch on 2014-8-18 18:17[/i] [table=98%] [tr][td]The webench online design software has a multi-power design solution specifically for FPGAs and microprocessors....
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
I. Introduction
In the field of power conversion, isolated converters (forward, flyback, and double-ended) with low output DC voltage all use MOSFET as the rectifier device. Since these devi...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
Smart lighting control systems provide high controllability for various buildings and further enhance the level of green energy. They are the core products of energy conservation and digital techn...[Details]
With the continuous consumption of earth's energy and the scarcity of resources, the harm of greenhouse effect to human beings, and the serious pollution of the atmosphere to the earth, the intern...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]
The traditional display screen using 51 single-chip microcomputer to control LED dot matrix has relatively simple functions. If it is to achieve diversified functions, it often takes a lot of time ...[Details]
TC9012F is a universal CMOS large-scale integrated circuit for infrared remote control signal transmission, suitable for remote control of TV, VTR, laser player and other equipment. In the market, ...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
FPGAs are used in 81% of electronic systems, including many commercial and defense products, and most FPGAs use BGA packaging. The BGA packaging is characterized by small solder balls and small sol...[Details]
At very low temperatures, certain metals and alloys lose their resistance to electric
current
and become
superconductors
. Two parameters that are often measured are the transition ...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]
Direct digital frequency synthesis (DDS) has fast frequency switching and modulation capabilities and is widely used. However, when low power consumption and low cost are the main considerations, D...[Details]
Current
measurement:
Magnetic balance Hall current
sensor
is used
. The sensor can measure AC from DC to 100kHz.