The R0.25S and R0.25D converters are of the enclosed open frame type, i.e. they are not
potted. The converters are typically used in general purpose and industrial low ower
isolation and voltage matching applications where an SMD converter is required.
The converter series feature an extended ambient temperature operating range of -40°C
to +100°C without derating and optional continuous short circuit protection. In addition
to single, dual and independent outputs, two isolation options and three different case
formats, the converters are also available prepacked as tape and reel for use with
automatic insertion machines.
Selection Guide
Part
Number
SMD
R0.25S**-xx3.3
R0.25S**-xx05
R0.25S**-xx09
R0.25S**-xx12
R0.25S**-xx15
R0.25S**-xx24
R0.25D**-xx3.3
R0.25D**-xx05
R0.25D**-xx09
R0.25D**-xx12
R0.25D**-xx15
R0.25D**-xx24
R0.25DA**-xx0505
R0.25DA**-xx1212
Input
Voltage
(VDC)
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
9
12
15
24
±3.3
±5
±9
±12
±15
±24
5/5
12/12
Output
Current
(mA)
76
50
28
21
17
10.4
±38
±25
±14
±10.4
±8.3
±5.2
25/25
10/10
Capacitive
Load
(max.)
1000µF
470µF
470µF
150µF
68µF
68µF
470µF
220µF
68µF
68µF
68µF
33µF
220µF/220µF
68µF/68µF
0.25 Watt SMD
Single, Dual
& Independent
Outputs
(3kV)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
2011/65/EU
6/6
RoHS
E358085
UL-60950-1 Certified
EN-60950-1 Certified
EN-60601-1 Certified*
*(/H suffix)
R0.25S
R0.25D(A)
Derating-Graph
(Ambient Temperature)
Standard Case
100
80
xx = Input Voltage (other input and output voltage combinations available on request)
* add Suffix “H” for 3kV Isolation, e.g. R0.25S-0505/H, R0.25D-0505/H, R0.25S12-0505/H, R0.25D12-0505/H
* add Suffix “P” for Continuous Short Circuit Protection, e.g. R0.25S8-0505/P, R0.25S-0505/HP, R0.25D12-0505/HP
* add suffix -R for tape & reel packing e.g. R0.25S-0505-R. For more details see Application Notes.
Case and Pinning Options (note restrictions on /H option)
R0.25S** : ** without marking denotes 5 pins out of 8 fitted (includes /H option)
** with marking 8 denotes 8 pins out of 8 fitted (/H option not available)
** with marking 12 denotes 10 pins out of 12 fitted (includes /H option)
R0.25D** : ** without marking denotes 6 pins out of 10 fitted (includes /H option, no DA option)
R0.25D(A): ** with marking 10 denotes with 10 pins out of 10 fitted (/H option not available)
R0.25D(A): ** with marking 12 denotes 10 pins out of 12 fitted (includes /H option - except R0.25DA)
Output Power (%)
60
40
20
0
Safe Operating Area
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
(low line to high line at max. load)
3.3V output types
5V, 5/5V output types
9V output type
12V, 12/12V, 15V, 24V output types
Output Ripple and Noise (20MHz BW limited)
Operating Frequency
±10%
±5% typ., ±7% max.
2% max.
15% typ., 20% max.
Output Power (%)
-40
100
110
Operating Temperature °C
0
50
150
Big Case (with marking 12)
100
80
60
40
30
20
0
12% typ., 15% max.
7% typ., 10% max.
6% typ., 10% max.
100mVp-p max.
Safe Operating Area
-40
20kHz min. / 50kHz typ. / 90kHz max.
continued on next page
REV: 0/2015
150
100
115
Operating Temperature °C
0
50
Refer to Application Notes
www.recom-power.com
E-8
ECONOLINE
DC/DC-Converter
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltage
H-Suffix
R0.25DA Output/ Output Isolation Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Reflow Temperature
Vapor Phase Process
Relative Humidity
Humidity Susceptibility Test
Package weight
Packing Quantity
R0.25S_R0.25D
Series
60%-70%
Specifications valid for 10% minimum load only
(tested for 1 second)
1000VDC
(rated for 1 minute***)
500VAC / 60Hz
(tested for 1 second)
3000VDC
(rated for 1 minute***)
1500VAC / 60Hz
(tested for 1 second)
1000VDC
75pF max.
Viso=500V
10 GΩ min.
1 Second
Continuous
-40°C to +100°C (see Graph)
-50°C to +125°C
ROHS compliant
245°C (30 sec), Peak 255°C (5 sec) max.
(for more details see Application Notes)
230°C (90 sec) max.
95% RH
1000 hrs / 90% humidity / +85°C ambient
1.0g (R0.25S), 1.2g (R0.25D(A))
R0.25S, R0.25S8
40 pcs per Tube
R0.25S12, R0.25D, R0.25D10
33 pcs per tube
R0.25D12, R0.25DA
33 pcs per tube
All Types
500 pcs per Reel
using MIL-HDBK 217F
4423 x 10
3
hours
using MIL-HDBK 217F
2161 x 10
3
hours
EN55022
Report: US/14402A/UL
Report: E358085
Report: MDD1205098-2 + RM1205098-2
Medical Report + ISO14971 Risk Assessment
Report: SPCLVD1211033-3
Level A
IEC 60950-1:2001 1st Ed.
UL 60950-1 2nd Ed.
C22.2 No. 60950-1-03
IEC/EN 60601-1 3rd Edition
EN60950-1:2006 + A12:2011
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
MTBF (+25°C)
Detailed Information see
Application Notes chapter "MTBF"
(+85°C)
Certifications
Conducted / Radiated Emissions
CB Test Report
UL General Safety
CUL General Safety
EN Medical Safety
}
R0.25S-
R0.25D
EN General Safety
***Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Typical Characteristics
R0.25S**-xx05
Efficiency / Load
R0.25D**-xx05
Efficiency / Load
100
80
60
40
Tolerance Envelope
+10%
Efficiency %
100
80
60
3.305
0505
0505
3.305
Efficiency %
+5%
V Nom.
Typical L
o
ad Line
+5%
1%
5%
40
20
0
1205
20
0
1205
Output Voltage
0% 20%
40%
60%
Total Output current (%)
Deviation / Load
80%
100%
0% 20%
40%
60%
Total Output current (%)
Deviation / Load
80%
100%
25.000
25.000
20.000
10%
50%
100%
Deviation from Nominal (%)
20.000
15.000
10.000
5.000
0.000
-5.000
-10.000
Output Load Current (%)
3.305
0505
Deviation from Nominal (%)
15.000
10.000
5.000
0.000
-5.000
-10.000
1205
3.305
1205
0%
40%
20%
60%
Total Output current (%)
80%
100%
0505
0%
40%
20%
60%
Total Output current (%)
80%
100%
www.recom-power.com
REV: 0/2015
E-9
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
R0.25S_R0.25D
Series
Note: /H option is available in
these pin packages
6 PIN Dual SMD Package
5 PIN Single SMD Package
12.75
10.7
8
5
10
7
6.7
RECOM
R0.25S-xxxx
xxxx
RECOM
R0.25D-xxxx
xxxx
15.24
10.7
6.7
2.54 x 3
7.0
8.50
11.10
7.0
2.54x4
8.50
11.10
1 2
4
1 2
4 5
Pin Connections
Recommended Footprint Details
0.50
12.00
8
Top View
Pin #
1
2
4
5
7
Single
–Vin
+Vin
–Vout
+Vout
No Pin
NC
No Pin
Dual
–Vin
+Vin
Com
–Vout
+Vout
No Pin
NC
Bottom View
Recommended Footprint Details
0.50
12.00
10
Top View
5
4
1.80
7
Bottom View
1 2
1 2
4 5
1.80
2.54
1.20
8
10
2.54
1.20
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
8 PIN Single SMD Package
Note: /H option is not available in
these pin packages
10 PIN Dual SMD Package
R0.25S-
R0.25D
12.75
10.7
8 7 6 5
10 9 8 7 6
RECOM
R0.25D10-xxxx
xxxx
RECOM
R0.25S8-xxxx
xxxx
15.24
10.7
6.7
2.54 x 3
7.0
8.50
11.10
6.7
2.54x4
7.0
8.50
11.10
1 2 3 4
Pin Connections
Pin #
1
2
3
4
5
6
7
8
9
10
Single
–Vin
+Vin
NC
–Vout
+Vout
NC
NC
NC
-
-
1 2 3 4 5
Recommended Footprint Details (Dual)
Dual
–Vin
+Vin
NC
Com
–Vout
NC
+Vout
NC
NC
NC
Dual
Independent
–Vin
+Vin
No Pin
-Vout1
+Vout1
-Vout2
+Vout2
No Pin
No Pin
NC
Bottom View
Bottom View
0.50
12.00
10 9 8 7 6
Top View
Recommended Footprint Details
0.50
12.00
8 7 6 5
Top View
1 2 3 4 5
1.80
Bottom View
1 2 3 4
1.80
2.54
1.20
2.54
1.20
Recommended Footprint Details Dual Independent
0.50
12.00
10
Top View
7 6
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
1 2
4 5
1.80
2.54
1.20
R0.25S** :** without marking denotes 5 pins out of 8 fitted (includes /H option)
** with marking 8 denotes 8 pins out of 8 fitted (/H option not available)
e.g. R0.25S-0505, R0.25S-0505/H, R0.25S-0505/HP
e.g. R0.25S8-0505, R0.25S8-0505/P
R0.25D** :** without marking denotes 6 pins out of 10 fitted (includes /H option)
e.g. R0.25D-0505, R0.25D-0505/H, R0.25D-0505/HP
** with marking 10 denotes with 10 pins out of 10 fitted (/H option not available) e.g. R0.25D10-0505, R0.25D10-0505/P
E-10
REV: 0/2015
www.recom-power.com
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
12 PIN Single and Dual SMD Package
15.24
12 11 10
RECOM
xxxx
R0.25S_R0.25D
Series
Note: /H option is available in
this pin package
10.7
Pin Connections
8 7
6.7
2.54x5
7.0
8.50
11.10
Recommended Footprint Details
Pin #
1
2
3
5
6
7
8
10
11
12
Single
–Vin
+Vin
NC
–Vout
NC
NC
+Vout
NC
NC
NC
Dual
–Vin
+Vin
NC
Com
-Vout
NC
+Vout
NC
NC
NC
R0.25S_R0.25D12-xxxx
1 2 3
5 6
R0.25S** :** with marking 12 denotes 10 pins
out of 12 fitted (includes /H option)
e.g. R0.25S12-0505
R0.25S12-0505/H
R0.25S12-0505/HP
0.55
Separation
> 3.8 mm
12 1110
1 2 3
8 7
5 6
1.80
R0.25D** :** with marking 12 denotes 10 pins
out of 12 fitted (includes /H option)
e.g. R0.25D12-0505
R0.25D12-0505/H
R0.25D12-0505/HP
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Bottom View
12.00
Top View
1.20
EMC Filtering - Suggestion for EN55022 Class B (Conducted and Emitted)
470pF/4kVDC
Fuse
Input
L1
Output
+
R0.25S-
R0.25D
C1
470pF/4kVDC
Fuse
Input
L1
+Vout
Standard and /H versions
C1
L1
Vin
2.2μF 3.3μH
3.3V
2.2μF 4.7μH
5V
1.0μF 22μH
12V
1.0μF 22μH
15V
470nF 47μH
24V
+
C1
Com
-Vout
470pF/2kVDC
Fuse
Input
L1
+Vout1
-Vout1
/P and /HP versions
C1
L1
Vin
2.2μF 3.3μH
3.3V
2.2μF 4.7μH
5V
1.0μF 22μH
12V
1.0μF 22μH
15V
470nF 47μH
24V
+
C1
+Vout2
-Vout2
470pF/2kVDC
C1 = MLCC
L1 = SMD Inductor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
What problems will occur when different cameras use centralized power supply? I found that the screen of some cameras is dim. What is the structure of the camera power supply circuit? How to solve suc...
The much-talked-about "Xu Ting Withdrawal Case" has finally come to an end, although the court's verdict is still controversial among netizens. But after the dust settled, we are still reflecting on o...
This is the code I used to create a ListCtrl, but it doesn't display. I dragged and dropped a ListCtrl in the Dialog dialog box and it still doesn't display. Does Wince SDK not support ListCtrl? [code...
[i=s]This post was last edited by lizoyu on 2016-3-27 22:36[/i] I have recently been working on my graduation project, which involves a stepper motor. Originally, I used a driver to drive it smoothly,...
Long ago, the lifespan of cars in my country was 15 years. Once a car reached 15 years old, it was forced to be scrapped. However, the policy was later changed. As long as the car does not exceed 6...[Details]
Is pure electric vehicles a false proposition for long-distance driving? At least from my personal perspective, based on current technological and infrastructure standards, I believe so. Below, I'l...[Details]
Topics: Bring Your Own Device (BYOD) trends; the impact of using employees' own mobile devices to control access to work facilities and equipment on information security; and ways to securely imple...[Details]
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[Details]
Since the beginning of this year, price wars have intensified, new models have been launched one after another, used cars with zero kilometers have become a hot topic, and the industry's internal c...[Details]
While the current industry consensus is that autonomous vehicles are robots and that their systems are managed using robotics-developed thinking, there are also cases where autonomous driving is ac...[Details]
According to Nikkei, Japan has performed poorly in responding to China's power semiconductor challenges.
There are five major companies in Japan's power chip market: Mitsubishi Electric,...[Details]
With the increasing popularity of automated equipment, linear modules, a common auxiliary device for automated equipment, have also seen a bright future. In particular, in recent years, many small ...[Details]
Compiled from semiengineering
The industry is increasingly concerned about power consumption in AI, but there are no simple solutions. This requires a deep understanding of software and ...[Details]
As the power density of modern electronic systems continues to increase, effective thermal management has become critical to ensuring system performance, reliability, and longevity—especially in hi...[Details]
The drive shaft is the shaft in a universal joint that transmits power. As a high-speed, low-support rotating body, its dynamic balance is crucial. Generally, drive shafts undergo dynamic balancing...[Details]
The drive shaft is a high-speed, low-support rotating body, so its dynamic balance is crucial. Generally, drive shafts undergo dynamic balancing tests and adjustments on a balancing machine before ...[Details]
1. Static Balance
Static balancing is performed on one correction surface of the rotor. The remaining unbalance after correction is used to ensure that the rotor is within the specified range ...[Details]
introduction
Commercial air conditioner PCBs involve both high-voltage and low-voltage power. The power supply for commercial air conditioners often passes through the controller. This forces ...[Details]
This article, part of Texas Instruments' "Power Supply Design Tips" series,
focuses on flyback converter design, discussing key design considerations for a 53VDC to 12V/5A continuous conduction...[Details]