Protections: Short circuit / Overload / Over voltage / Over temperature
1500VAC I/O isolation
Cooling by free air convection
100% full load burn-in test
24V and 48V input voltage design refer to LVD
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
INPUT
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
(for SD-200C-24 type only)
SD-200B
5V
34A
0 ~ 34A
170W
4.5 ~ 5.5VDC
±0.5%
±1.0%
B:19 ~ 36VDC
79%
12V
16.7A
0 ~ 16.7A
200.4W
120mVp-p
11 ~ 16VDC
±1.0%
±0.5%
±1.0%
24V
8.4A
0 ~ 8.4A
201.6W
150mVp-p
23 ~ 30VDC
±1.0%
±0.5%
±1.0%
48V
4.2A
0 ~ 4.2A
201.6W
200mVp-p
43 ~ 53VDC
±1.0%
±0.5%
±1.0%
D:72 ~144VDC
86%
10.4A/24V
81%
5.4A/48V
84%
5.2A/48V
SD-200C
5V
40A
0 ~ 40A
200W
100mVp-p
4.5 ~ 5.5VDC
±2.0%
±0.5%
±1.0%
12V
16.7A
0 ~ 16.7A
200.4W
120mVp-p
11 ~ 16VDC
±1.0%
±0.5%
±1.0%
(for D type only)
24V
8.4A
0 ~ 8.4A
201.6W
150mVp-p
23 ~ 30VDC
±1.0%
±0.5%
±1.0%
48V
4.2A
0 ~ 4.2A
201.6W
200mVp-p
43 ~ 53VDC
±1.0%
±0.5%
±1.0%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
300ms, 50ms at full load
C:36 ~ 72VDC
82%
85%
86%
6.7A/48V
86%
5A/48V
10.8A/24V
10.6A/24V
10.4A/24V
C:45A/48VDC
D:45A/96VDC
105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
5.75 ~ 6.75V 16.8 ~ 20V
31.5 ~ 37.5V 53 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
5.75 ~ 6.75V
16.8 ~ 20V
31.5 ~ 37.5V
53 ~ 65V
Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +60
℃
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
℃
, 10 ~ 95% RH
±
0.03%/
℃
(0 ~ 50
℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1approved (for SD-200C-24 type only), IEC60950-1 CB approved by TUV (for D type only)
I/P-O/P:1.5KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A
218.2K hrs min. MIL-HDBK-217F (25
℃
)
215*115*50mm (L*W*H)
1.1Kg; 12pcs/14.4Kg/0.92CUFT
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:SD-200-SPEC 2015-05-29
200W Single Output DC-DC Converter
■
Features :
2:1 wide input range
SD-200
series
Protections: Short circuit / Overload / Over voltage / Over temperature
1500VAC I/O isolation
Cooling by free air convection
100% full load burn-in test
24V and 48V input voltage design refer to LVD
2 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
INPUT
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
NOTE
(for D type only)
SD-200D
5V
40A
0 ~ 40A
200W
4.5 ~ 5.5VDC
±0.5%
±1.0%
300ms, 50ms at full load
B:19 ~ 36VDC
82%
3.5A/96V
C:45A/48VDC
C:36 ~ 72VDC
82%
3.5A/96V
D:45A/96VDC
D:72 ~144VDC
84%
3.5A/96V
90%
3.5A/96V
12V
16.7A
0 ~ 16.7A
200.4W
120mVp-p
11 ~ 16VDC
±1.0%
±0.5%
±1.0%
24V
8.4A
0 ~ 8.4A
201.6W
150mVp-p
23 ~ 30VDC
±1.0%
±0.5%
±1.0%
48V
4.2A
0 ~ 4.2A
201.6W
200mVp-p
43 ~ 53VDC
±1.0%
±0.5%
±1.0%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
5.75 ~ 6.75V
16.8 ~ 20V
Protection type : Shut down o/p voltage, re-power on to recover
31.5 ~ 37.5V
53 ~ 65V
Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +60
℃
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
℃
, 10 ~ 95% RH
±
0.03%/
℃
(0 ~ 50
℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
IEC60950-1 CB approved by TUV (for D type only)
I/P-O/P:1.5KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
℃
/ 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A
218.2K hrs min. MIL-HDBK-217F (25
℃
)
215*115*50mm (L*W*H)
1.1Kg; 12pcs/14.4Kg/0.92CUFT
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.