EEWORLDEEWORLDEEWORLD

Part Number

Search

HWS50A-15-A

Description
Toggle Switches 1 Pole 2 Position Standard Lever QC
CategoryPower/power management   
File Size482KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet Parametric View All

HWS50A-15-A Online Shopping

Suppliers Part Number Price MOQ In stock  
HWS50A-15-A - - View Buy Now

HWS50A-15-A Overview

Toggle Switches 1 Pole 2 Position Standard Lever QC

HWS50A-15-A Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerTDK Corporation
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 115 V
Number of Outputs1 Output
Output Power50 W
Open Frame/EnclosedEnclosed
Input Voltage265 VAC/370 VDC
Output Current-Channel 13.5 A
Commercial/MedicalCommercial
Isolation Voltage500 VDC
Mounting StyleChassis
Length120 mm
Width31.5 mm
Height82 mm
Input Frequency63 Hz
Load RegulationRegulated
PackagingBulk
Power - Convection50 W
Factory Pack Quantity1
Unit Weight10.582189 oz
HWS15A-150A/A Series
50-150W Single Output Industrial Power Supplies
Features
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
Higher Efficiency Than HWS series
Key Market Segments & Applications
Specifications
Model
Input Voltage Range
Input Current (Typ) (1)
Inrush Current (1)
-
A
A
-
Power Factor (1)
-
Temperature Coefficient
%/°C
Overcurrent Protection
%
Overvoltage Protection
V
Hold Up Time (Typ)
ms
Leakage Current (max)
mA
Remote Sense
-
Indicator
-
Operating Temperature (with cover) °C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Withstand Voltage
VAC
Isolation Resistance
M Ohms
Vibration (non operating)
-
Shock
m/s
2
Safety Agency Approvals
-
Line Dip
-
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD) (with cover)
Inches
mm
MTBF - Telcordia SR-332 issue 3**
Hours
Warranty
-
HWS15A/A
HWS30A/A
HWS50A/A
HWS100A/A
HWS150A/A
85 - 265VAC (47 - 63Hz) or 120 - 370VDC* (Withstands 300VAC for 5s)
0.35 / 0.2
0.65 / 0.4
0.65 / 0.35
1.3 / 0.65
1.9 / 0.95
14 / 28
Meets EN61000-3-2
-
-
0.97/0.91
0.98/0.93
0.98/0.93
<0.02%/°C
>105%
Yes
20
>0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
No
Yes
Green LED = ON
-10°C to +70°C, derate linearly to 20% load from 50°C to 70°C (2)
-30 to +85°C
Operating: 30 - 90%RH, Non operating 10 - 95%RH
Convection
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
190
240
300
470
520
1.24x3.23x3.15 1.24x3.23x3.74 1.24x3.23x4.72
1.3x3.23x6.3
1.65x3.23x6.3
31.5x82x80
31.5x82x95
31.5x82x120
33x82x160
42x82x160
12,116,851
8,169,868
3,726,622
2,963,512
2,676,081
Limited lifetime warranty (See website for terms & conditions)
* Safety certified for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input
(1) 100/200VAC
(2) HWS15A/A derates linearly to 50% load from 50 to 70°C
1-800-526-2324 • www.us.tdk-lambda.com/lp/
14
Disclaimer: us.tdk-lambda.com/lp/legal.htm
【Project Outsourcing】Photodetector Design
Overview: The two optical signals are converted into electrical signals, which are then amplified and sampled by an A/D converter. Feature Request: 1.RS232 serial communication; 2.Switch control of sa...
hzxfy Medical Electronics
Questions about creating schematic package in Orcad
When using Orcad to create schematic packages, is it better to put all the packages into one OLB library, or to generate one OLB library for each package? As shown in the picture:...
elec32156 PCB Design
[MSP430 Sharing] Dynamic reactive power compensator based on power chip ATT 7 0 2 2 B
This paper introduces the energy metering chip AT17022B and MSP430F449 produced by 11 company, and combines the application of various power parameter collection in the dynamic reactive power compensa...
鑫海宝贝 Microcontroller MCU
There are 3 more opportunities to participate in the DIY emergency light project. If you are interested, please submit your proposal
There are currently three opportunities to participate in this emergency lighting project.What you need to do: 1. Use MAXIM chip to DIY emergency light, submit the plan and schematic diagram; 2. Apply...
soso DIY/Open Source Hardware
Can someone tell me: when the voltage regulator wakes up from low power consumption.
The wake-up delay of STANDBY should be = the time for the voltage regulator to wake up from low power consumption + the HSI RC wake-up time. The latter HSI oscillator startup time tsu = 1-2μs. How muc...
ye12 stm32/stm8
pxa270 + spi + wifi problem!!! Urgent!!! Waiting online!!!!!!
Now I use Lingyi's WIFI. The hardware platform is PXA270 and the interface is SPI. At present, the system has initialized SPI, and then read the WIFI ID normally. However, when loading the firmware, t...
shortt Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 787  2734  2773  1828  1332  16  56  37  27  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号