EEWORLDEEWORLDEEWORLD

Part Number

Search

FSB-20-104-H

Description
Power Line Filters AC 3 Phase 500 20A High Attenuation
Categorysemiconductor    Power management   
File Size372KB,3 Pages
ManufacturerCosel
Download Datasheet Parametric View All

FSB-20-104-H Online Shopping

Suppliers Part Number Price MOQ In stock  
FSB-20-104-H - - View Buy Now

FSB-20-104-H Overview

Power Line Filters AC 3 Phase 500 20A High Attenuation

FSB-20-104-H Parametric

Parameter NameAttribute value
Product CategoryPower Line Filters
ManufacturerCosel
RoHSDetails
Unit Weight4 lbs
FSB series(10,20,30A)
R
Three phase input type(2-stage filter)
Ordering information
FSB -30 -324
1
2
3
4
-O
1
Model Name
2
Rated Current
3
Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Leakage Current
*
1
Line to ground Line to ground
Upper row :
D-connection
capacitor CY1 capacitor CY2
Lower berth : Wye-connection (nominal value) (nominal value)
1.0mA/2.0mA max
203
0.01μF
0.01μF
0.1mA/0.2mA max
2.5mA max/Not applicable
573
*
2
0.01μF
0.047μF
0.35mA max/Not applicable
2.5mA/5.0mA max
693
0.022μF
0.047μF
0.35mA/0.7mA max
3.5mA/7.0mA max
104
0.033μF
0.068μF
0.5mA/1.0mA max
12mA max/Not applicable
254
*
2
0.033μF
0.22μF
1.5mA max/Not applicable
12mA/24mA max
324
0.1μF
0.22μF
1.5mA/3.0mA max
160mA max/Not applicable
335
*
2
0.033μF
3.3μF
20mA max/Not applicable
180mA/270mA max
355
0.22μF
3.3μF
25mA/50mA max
Code
*
When the line to ground capacitor code is different, the
The terminal cover is retracted inside the unit
Features of FSB series
EMI/EMC Filter for motor drive system (AC servo)
-
Improve saturation resistance (There is such as performance improvement
type “-254-HU”)
-
Book type (Space-saving type)
-
Quick and easy push-down terminal
Just connect the wires,push-down and tighten the screws with a screwdriver
attenuation characteristic is different.
*
1
Input 250/500V 60Hz (Only
D-connection
of “355” is 250/400V 60Hz)
*
2
Only “U” type is applied.
Specifications
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
*3
*4
*5
*6
4
Option
H :Ultra high attenuation type
U :Improve differential mode attenuation (Rated voltage 250V)
Only “573”, “254”, “335” is applied.
Items
Rated Voltage[V]
Rated Current[A]
Test Voltage (Terminal-Mounting Plate)
Isolation Resistance (Terminal-Mounting Plate)
Leakage current 250/500V 60Hz
DC registance
Safety agency approval temperatures
Operating temperature
Operating humidity
Storage temperature/humidity
Vibration
Impact
Safety agency approvals
Case size (without projection)
Weight
FSB-10-324
FSB-20-324
FSB-30-324
AC Three Phase 500 (voltage range:528 max) 50/60Hz
*3 *4
10
20
30
2,800 VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity
*5
500 VDC 100MW min at room temperature and humidity
*6
12mA/24mA max
100mW max
38mW max
20mW max
-25 to +85C (Refer to Derating Curve)
-40 to +85C (Refer to Derating Curve)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
10 to 55Hz, 19.6m/s
2
(2G), 3min. Period, 1hour each X, Y and Z axis
196.1m/s
2
(20G), 11ms Once each X, Y and Z axis
UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil 3-1, ENEC
66X100X240 mm (WXHXD)
[2.60X3.94X9.45 inches] (WXHXD)
1.8kg max
Only capacitor code “355”,Three Phase
D-connection
: 400 (440 max), Wye-connection : 500 (528 max)
Only “FSB-OO-OOO-U”, Three Phase 250 (275 max)
Only capacitor code “203”, “573”, “693”, “104”, 2,500VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity.
Only capacitor code “335”, “355”, Isolation resistance specification is deleted.
Circuit Diagram
(1) Line to ground capacitor code : 203, 693, 104, 324
LINE
LINE
1
1
2
2
3
3
Case
Case
LOAD
LOAD
4
4
5
5
6
6
Derating Curve
(2) Line to ground capacitor code : 355
Load Factor [%]
LINE
LINE
1
1
2
2
3
3
Case
Case
LOAD
LOAD
4
4
5
5
6
6
100
80
70
60
40
20
10
0
-40
CY1
CY1
CY1
CY1
CY1, CY2 :
CY1, CY2 :
:
:
CY2
CY2
CY2
CY2
Line to ground capacitor
Line to ground capacitor
Mounting plate
Mounting plate
CY1
CY1
CY1
CY1
CY1, CY2 :
CY1, CY2 :
:
:
CY2
CY2
Line to ground capacitor
Line to ground
Mounting plate capacitor
Mounting plate
-30
-20
40
50
60
70
80
90
Ambient Temperature [C]
*Keep
free ventilation holes for cooling.
(3) Line to ground capacitor code : 573, 254
Option : U
LINE
LINE
1
1
2
2
3
3
Case
Case
LOAD
LOAD
4
4
5
5
6
6
(4) Line to ground capacitor code : 335
Option : U
LINE
LINE
1
1
2
2
3
3
Case
Case
LOAD
LOAD
4
4
5
5
6
6
EMI/EMC
Filter
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY2
CY2
CY2
CY2
Line to ground capacitor
Line to ground
Mounting plate capacitor
Mounting plate
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY1
CY2
CY2
Line to ground capacitor
Line to ground
Mounting plate capacitor
Mounting plate
CY1, CY2 :
CY1, CY2 :
:
:
CY1, CY2 :
CY1, CY2 :
:
:
NF-106

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 857  444  1674  1158  555  18  9  34  24  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号