AC/DC SWITCHING POWER SUPPLY
AC INPUT 85~264
SINGLE CHANNEL OUTPUT
300 WATTS
FHF-SX-U1
SERIES
General Description
FH-Series is a new generation of power supplies. It’s
the latest design following international standards and
market demands. This type of power supply has all in
one: These supplies incorporate Power Factor Correction
(PFC), low line distortion per IEC61000-3-2 and
universal inputs. (EMI) complies with VDE 0871/B,
EN50022/B, FCC level B. Safety complies with VDE/EN
60950-1, CSA 234. Size is compatible with WR-series.
High efficiency and near unity power factor: an optimal
combination of cost and performance for both power user
and supplier.
Application
Industrial
Features
1.
Power factor correction
Power factor > .98
Immunity against surge and burst
Input
Input Voltage Nominal:
Input Voltage Range:
Input Current:
Frequency:
Input Frequency Range:
Phase:
Inrush Current:
*1
Leakage Current:
AC115-230V
AC85-264V
2.4-4.9A
50/60Hz
47-63Hz
Single
12A(max.) at AC115V
24A(max.) at AC230V
1mA(maximum)at 25
C
(
rated input/output and
rated input frequency)
2.
3.
Options
N/A
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com
DIMENSION DIAGRAM(mm)
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com
BLOCKDIAGRAM
** Note: All FHF series have “ - U1” suffix
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com
Environmental Specification
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Vibration
Shock
Cooling
Environmental Agencies
Line Conducted Noise
Line Harmonic Distortion
Safety
MTBF [H]
Switching Frequency[kHz]
- 5 to +50˚C
30 to 85%/RH(non - condensing)
- 20 to +85
˚C
10 to 85%/RH(non - condensing)
Primary - Secondary AC3,000V for 1minute
Primary - Frame Ground AC2,500V for 1minute
Secondary- Frame Ground AC500V for 1minute
Primary - Secondary- Frame Ground
50MΩ(minimum) by DC500V
insulation tester
5- 10Hz:10mm double amplitude,10 - 55Hz:19.6m/s2,20minutes'
period for 60minutes each along X,Y,Z axes(non
-
operating)
294m/s
2
Convection
Built to meet FCC Part15 - B Class B
Built to meet VCCI Class B
Built to meet
VDE0801
Class B
Built to meet IEC61000
- 3- 2
UL:60950- 1 2
nd
edition C- UL: CSA C22.2 No.950
VDE EN60950
- 1 2006,
IEC950, VDE0805
130,000
100(typ.)
Available, automatic return at rated 110%
Available, automatic return at rated 110%
Available
Available
Available
Available
~119.9 x 169.9 x 93.0
1900g
Function/Protection
Over current Protection
Over voltage Protection
Remote Sense
Remote On/Off
Power Fail Detection
Series Operation
Parallel Operation
Mechanical
Dimension [mm]
Weight [g](typical)
Conditions:
*1 cold start
*2 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth
*3 when output current changed from 50% to 150% of rated output current rapidly at rated input
*4 at - 10 to +50˚C
*5 for 7hour period after 1hour warm-up at 25˚C and rated input/output
*6 safety approved at 25
˚
C
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com
DERATING CURVE
EFFICIENCY CURVE
OCP CURVE
ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753
Visit us at: www.eta-usa.com
email at: sales@eta-usa.com