• Optional with undervoltage release or remote trip release
• All single elements wired
• With EMC-shield
• Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
Rated currents I
n1)
125/250 VAC; 50/60 Hz
12/16 A
@ T
a
40 °C; VDE
12/16/20 A @ T
a
40 °C; UL/CSA
10 up to 16 A; VDE, see table 1
10 up to 20 A; UL/CSA, see table 1
< 0,5 mA (250 V/60Hz)
< 5 µA (250 V/60Hz)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
Filter
TA 45
Leackage current, Standard
Medical
Test voltage (2 sec)
Allowable ambient air
temperatures T
a
–10 °C to +55 °C
Climatic category
10/055/21 acc.to IEC/EN 60068-1
Degree of protection (front side) IP40 acc. to IEC 60529
suitable for equipment with prot. cl. I,
Protection class
acc. to IEC 61140
Terminals
quick-connect 6,3 x 0,8 mm
Panel thickness s
s = max. 8 mm
Materials: Housing, plastic part Thermoplastic, black, UL94 V-0
Appliance-inlet
Circuit breaker
type TA 45
acc. to IEC/EN 60320-1/C20,
Protection class I,
pin-temperature 70 °C (cold condition)
acc. to IEC/EN 60934, UL 1077,
CSA 22.2 no 235
2-pole rocker switch,
non-illuminated.
Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at I
n
< 3 A/240 VAC: 10 x I
n
at I
n
≥
3 A/240 VAC: 300 A
acc.to IEC 60939/EN 133200/
UL 1283/CSA C22.2 no 8
Line filter,
standard and medical
1)
Application note
The rated current of the line-filter must be equal or higher than the
rated current of the circuit-breaker.
www.schurter.com
POWER ENTRY MODULE
/ GERÄTESTECKER-KOMBIELEMENT
Technical data (continued)
Circuit breaker
Tripping characteristics
/
In < 3 A
[ min ] [ sec ]
10'000
Type
/ Typ
Rated current
Nennstrom
TA45
In <3 A
1 pole protected
1polig geschützt
2 pole protected
2polig geschützt
+23
°C
EF12
Tripping characteristics
/
In
≥
3… < 18 A
[ min ] [ sec ]
10'000
Type
/ Typ
Rated current
Nennstrom
TA45
3 A
≥
In <18 A
1 pole protected
1polig geschützt
2 pole protected
2polig geschützt
+23
°C
Tripping characteristics
/
In
≥
18 A
[ min ] [ sec ]
10'000
Type
/ Typ
Rated current
Nennstrom
TA45
In
≥18
A
1 pole protected
1polig geschützt
2 pole protected
2polig geschützt
+23
°C
60
30
20
10
5
200
100
1
50
2`000
1`000
500
60
30
20
10
5
200
100
1
50
2`000
1`000
500
60
30
20
10
5
200
100
1
50
2`000
1`000
500
Ambient temp.
Umgebungstemp.
Ambient temp.
Umgebungstemp.
Ambient temp.
Umgebungstemp.
20
10
5
2
1
0,5
Tripping time
Tripping time
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
10
20
10
5
2
1
0,5
20
10
5
2
1
0,5
Tripping time
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
10
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
10
Multiple of rated current
[ x In ]
Multiple of rated current
[ x In ]
Multiple of rated current
[ x In ]
Effect of ambient temperature
The unit is calibrated for an ambient tempe-
rature of +23 °C. To determine the rated
current for a lower or higher ambient tempe-
rature, use a correction factor from the table
on the right side:
* Ambient temperature [°C] /
* Umgebungs-
–10
–5
0
+23
+30
+40
+55
Correction
factor /
0,89
0,91
0,92
1,00
1,03
1,08
1,16
Example
Rated current at +23 °C
Nennstrom bei +23 °C
Ambient temperature
Umgebungstemperatur
Correction factor
Korrekturfaktor
Chosen rated current at
+40 °C ambient temperature
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
* Temperature must be measured at the rear
of the breaker next to the terminals after
equipment operating temperature has been
reached.
Dimensions
Screw-on mounting
76,2*
37
±0.15
+0.05
32.2
-0.10
Panel cut-out
10.6
41.2
0.8
2.8
32.9
R3
.0
5
R
3.
55
±
0.
05
79.2
-0.15
+0.05
90
-0.15
12.2
±0.08
40.55
90
±0.10
12.55
R
5
3.5
.05
±
0
R
2.
R
5.5
8
10.9
s
9.5
59.5
5.3
R6
.5
Ø 3.3
±0.05
Ø 6.4
Ø
3.6
33.9
±0.10
Mounting screw torque 0,5 Nm
*
Version
TA45 with undervoltage release
www.schurter.com
4.55
±0.05
4.
7
81
±0.10
+0.05
80.05
101
POWER ENTRY MODULE
/ GERÄTESTECKER-KOMBIELEMENT
Derating curve
Correlation between max. operating current I and the ambient air
temperature T
a
Diagram
Line-switch non-illuminated
EF12
Operating current I in % of In /
Standard version
Medical version
Ambient air temperature T
a
ºC /
Umgebungstemperatur T
u
in °C
Technical data of filters-components
Rated current
/
Nennstrom
(A)
12
16
20
12
16
20
Filter-Type
/
Filter-Typ
Standard
Inductance
/ Induktivitäten
L 1/L2 (mH)
2 x 0,8
2 x 0,6
2 x 0,3
2 x 0,8
2 x 0,6
2 x 0,3
Capacitance
/ Kapazitäten
CX (nF)
CY (nF)
100
2 x 2,2
R
(MΩ)
1
1
DC-Resistance
@ 25 °C (mΩ)
7,5
5
3,5
7,5
5
3,5
Medical
Medical
100
1
1
Attenuation loss line-filter
/
Einfügungsdämpfung Netzfilter
12 A
Standard version
/
Standardversion
16 A
20 A
12 A
Medical version
16 A
20 A
Order code for EF12 (order example)
Type /
Order code TA45 /
(2-pole rocker-switch
without accessories) /
Line filter, rated current,
1 = 20 A, 2 = 16 A, 3 = 12 A
Line filter version,
1 =
standard,
2 =
medical
Terminals
1 =
Quick connect terminals
6,3 x 0,8 mm
Panel mount:
0 =
Screw-on version
Protection class: 0 = Class I, housing black
Wiring: 1 = wired
F2
.
A B T W F 1 5 0 C 0
.
see table 1
11 10. 0 1
Please note that Schurter will establish an internal new part number for logistical use in addition to the order code. For example, order code F2ABTWF200C0111
will reflect the internal part number of EF12.0035.1110.01.
Application note
The rated current of the line-filter must be equal or less than the rated current of the circuit-breaker
Other versions on request
• Rocker switch illuminated
}
www.schurter.com
POWER ENTRY MODULE
/ GERÄTESTECKER-KOMBIELEMENT
Table 1
Selection for type TA45
Order example
• Line-switch
• 2-pole, rocker actuated
• Quick connect terminal
5
3
P1
EF12
150
C0
ABT
W
F
a
Other types on request
Diagram
P2
P1
P2
P1
P2
P1
Without illumination
With illumination
/
220…240 V
Mit Beleuchtung
110…120 V
6
5
6
3
4
3
ABC
A02
A04
ABT
A12
A14
ABD
A32
A34
}
Colours
Switch front
/
Rocker
W
B
6
black
/ schwarz
black
/ schwarz
black
/ schwarz
white
/ weiss
black
/ schwarz
–
–
–
orange transp.
Rocker legend
Surface
/
Illustration
/
Colour of print
/
O
Surface
/
Illustration
/
Colour of print
O
O
O
F
H
K
L
embossed
printed
/ bedruckt
printed
/ bedruckt
printed
/ bedruckt
l
M
white
black
white
P
R
printed
/ bedruckt
printed
/ bedruckt
printed
/ bedruckt
l
black
white
black
OFF OFF
ON
I
I
ON
l
O
Position of the rocker legend
e. g F
• Without thermal overload protection: code C00
I
n
= 16 A
• With thermal overload protection: rated current In (A)