EEWORLDEEWORLDEEWORLD

Part Number

Search

MAX6465UK38-T

Description
Supervisory Circuits Ultra-Low-Power Voltage Detectors and Microprocessor Supervisory Circuits
CategoryPower/power management    The power supply circuit   
File Size179KB,10 Pages
ManufacturerMaxim
Websitehttps://www.maximintegrated.com/en.html
Download Datasheet Parametric View All

MAX6465UK38-T Online Shopping

Suppliers Part Number Price MOQ In stock  
MAX6465UK38-T - - View Buy Now

MAX6465UK38-T Overview

Supervisory Circuits Ultra-Low-Power Voltage Detectors and Microprocessor Supervisory Circuits

MAX6465UK38-T Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerMaxim
Parts packaging codeSOT-23
package instructionSOT-23, 5 PIN
Contacts5
Reach Compliance Codenot_compliant
ECCN codeEAR99
Adjustable thresholdNO
Analog Integrated Circuits - Other TypesPOWER SUPPLY SUPPORT CIRCUIT
JESD-30 codeR-PDSO-G5
JESD-609 codee0
length2.9 mm
Humidity sensitivity level1
Number of channels1
Number of functions1
Number of terminals5
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Package body materialPLASTIC/EPOXY
encapsulated codeLSSOP
Encapsulate equivalent codeTSOP5/6,.11,37
Package shapeRECTANGULAR
Package formSMALL OUTLINE, LOW PROFILE, SHRINK PITCH
Peak Reflow Temperature (Celsius)245
power supply1.2/6 V
Certification statusNot Qualified
Maximum seat height1.45 mm
Maximum supply current (Isup)0.0035 mA
Maximum supply voltage (Vsup)6 V
Minimum supply voltage (Vsup)1 V
Nominal supply voltage (Vsup)3.6 V
surface mountYES
technologyBICMOS
Temperature levelAUTOMOTIVE
Terminal surfaceTin/Lead (Sn/Pb)
Terminal formGULL WING
Terminal pitch0.95 mm
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
width1.625 mm
19-2533; Rev 2; 12/05
Ultra-Low-Power Voltage Detectors and
µP Supervisory Circuits
General Description
The MAX6461–MAX6466 family of ultra-low-power voltage
detectors and µP reset supervisory circuits monitors bat-
tery, power-supply, and system voltages. Each circuit
includes a precision bandgap reference, a comparator,
internally trimmed resistor networks that set specified trip
thresholds, and an internal 5% threshold hysteresis circuit
(see the
Functional Diagram).
Output is asserted when
V
CC
falls below the internal V
TH-
and remains asserted
until V
CC
rises above V
TH
+ (V
TH
+ = V
TH
-
×
1.05). These
devices provide excellent circuit reliability and low cost
by eliminating external components and adjustments
when monitoring nominal system voltages from +1.6V to
+5.5V. The MAX6461/MAX6462/MAX6463 are voltage
detectors with a propagation delay of 17µs.
The MAX6464/MAX6465/MAX6466 are µP supervisory
circuits with a minimum reset timeout period of 150ms. All
devices are available with thresholds from +1.6V to +5.5V
in 100mV increments.
The family is available with three output stage options:
push-pull with active-low output, push-pull with active-
high output, and open drain with active-low output. These
devices are available in SC70 and SOT23 packages
specified over the -40°C to +125°C temperature range.
Ultra-Low 1.0µA Supply Current
Preset Thresholds from +1.6V to +5.5V in 100mV
Increments
Internal 5% Threshold Hysteresis
±2.5% Threshold Accuracy Over Temperature
Internal Timeout Period Option (150ms min)
Immune to Short Voltage Transients
No External Components
Available in Three Output Options: Push-Pull
(Active Low/Active High) and Open Drain (Active
Low)
Fully Specified from -40°C to +125°C
Small SC70 and SOT23 Packages
Features
MAX6461–MAX6466
Ordering Information
PART
MAX6461XR_
_-T
MAX6461UR_ _-T
MAX6461UK_ _-T
MAX6462XR_
_-T
MAX6462UR_ _-T
MAX6462UK_ _-T
TEMP RANGE
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
-40°C to +125°C
PIN-PACKAGE
3 SC70-3
3 SOT23-3
5 SOT23-5
3 SC70-3
3 SOT23-3
5 SOT23-5
Applications
Precision Battery Monitoring
Load Switching/Power Sequencing
Power-Supply Monitoring in Digital/Analog
Systems
Noise-Immune µP Reset Circuits
Portable/Battery-Powered Equipment
Cellular Phones/Cordless Phones
PDAs
Portable Medical Devices
The MAX6461–MAX6466 are available in factory-set thresholds
from 1.6V to 5.5V in approximately 100mV increments. Choose
the desired voltage threshold suffix from Table 1 and insert it in
the blank spaces in the part number. There are 30 standard ver-
sions with a required order increment of 2500 pieces. Sample
stock generally is held on the standard versions only (Table 2).
Nonstandard versions require a 10k-piece order increment.
Contact factory for availability. All devices available in tape-and-
reel only.
Devices are available in both leaded and lead-free packaging.
Specify lead-free by replacing “-T” with “+T” when ordering.
Ordering Information continued at end of data sheet.
Selector Guide appears at end of data sheet.
Pin Configurations
TOP VIEW
GND 1
N.C.
1
5
V
CC
(OUT)/OUT 1
MAX6461–
MAX6466
(OUT)/OUT 2
3
V
CC
GND 2
MAX6461–
MAX6466
GND 2
4
(OUT)/OUT
MAX6461–
MAX6466
3
V
CC
SC70-3
( ) ARE FOR THE MAX6462/MAX6465 ONLY
GND 3
SOT23-3
SOT23-5
________________________________________________________________
Maxim Integrated Products
1
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
Ask a LWIP question
I am running LWIP on LM3S in RAW mode. I called TCP_WRITE() in a FOR loop to send data. I found that if the number of loops is too many, the subsequent data will fail to be sent. How many times can TC...
ebuffalo Microcontroller MCU
MCU Life-The Most Tough Life Biography
On a certain day in a certain delivery room, you were born (power up), but you didn't cry. The doctor lifted you up and slapped you hard on the buttocks, and you cried loudly (reset, reset successful)...
daijun MCU
【MSP430 Sharing】Wireless communication solution for engineering machinery instruments based on RF technology
Aiming at the communication problem of various signals of large-scale engineering machinery and remote display of instruments in the driving control room, a design scheme for realizing wireless data c...
鑫海宝贝 Microcontroller MCU
Where can I find 12V DC motor driver IC?
Where can I find a 12V DC motor driver IC?...
wlh1204 Analog electronics
Which teacher is familiar with the electrical part of the electric actuator?
The questions I want to ask are: 1. Working cycle: maximum 15% or 2min continuous use, 15min rest, are you afraid of burning out the components? Why? [/size][/size][/font] [font=宋体][size=10.5pt][size=...
simonprince Analog electronics
How to use the arrow keys to control the mouse movement? I made one. After pressing the arrow keys, the mouse position moves, but when the mouse moves, it returns to its original position. Why?
How to use the arrow keys to control the mouse movement? I made one. After pressing the arrow keys, the mouse position moves, but when the mouse moves, it returns to its original position. Why?...
stdio_h_0 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1093  2589  1771  973  790  23  53  36  20  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号