EEWORLDEEWORLDEEWORLD

Part Number

Search

ED2-3TNJ

Description
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.011A (COIL), 4.5VDC (COIL), 50mW (COIL), 1A (CONTACT), 220VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size106KB,16 Pages
ManufacturerNEC ( Renesas )
Websitehttps://www2.renesas.cn/zh-cn/
Download Datasheet Parametric View All

ED2-3TNJ Overview

POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.011A (COIL), 4.5VDC (COIL), 50mW (COIL), 1A (CONTACT), 220VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

ED2-3TNJ Parametric

Parameter NameAttribute value
Maximum operating temperature85 Cel
Minimum operating temperature-40 Cel
stateACTIVE
Coil power50 mW
Relay actionTransient
Relay functionDouble Knife Double Throw
Coil resistance405 ohm
Electrical life1.00E6 Cycle(s)
Manufacturer SeriesED2
Maximum DC coil current0.0110 A
Maximum DC coil voltage4.5 V
Maximum AC contact current1 A
Maximum DC contact current1 A
Maximum AC contact voltage250 V
Maximum DC contact voltage220 V
DC coil operating voltage3.38 V
DC coil release voltage0.4500 V
width7.5 mm
high9.4 mm
length or diameter15 mm
Installation featuresThrough hole installation
operating hours3 ms
Relay typePOWER/SIGNAL RELAY
release time2 ms
Terminal typewelding
DATA S H E E T
MINIATURE SIGNAL RELAY
ED2/EF2 SERIES
Ultra-low power, compact and lightweight, High breakdown voltage,
Surface mounting type
DESCRIPTION
NEC's new miniature signal relays, ED2/EF2 series, achieved 50 mW of ultra low power consumption.
FEATURES
Low power consumption (50 mW)
Applicable for the surge voltage standard of FCC (1500 V, 10
×
160
µ
s) and BELLCORE (2500 V, 2
×
10
µ
s)
Two types for through-hole mounting (ED2 series) and surface mounting (EF2 series)
Variation of dense mounting type and/or long-joint-life type for latest SMT
• Compatible configuration and terminal allocation with dense mounting type of EE2 series
• Upgraded soldering joint reliability between the relay terminal and PCB by optimization of the terminal
configuration;
20-year-joint-life under 35˚C-per-day-temperature-difference specified in IPC-SM-785 for telecommuication
equipment
APPLICATIONS
Electronic switching systems, PBX, terminal equipment, telephone system, instrumental equipment.
For Right Use of Miniature Relays
DO NOT EXCEED MAXIMUM RATINGS.
Do not use relays under exceeding conditions such as over ambient temperature, over voltage
and over current. Incorrect use could result in abnormal heating, damage to related parts or
cause burning.
READ CAUTIONS IN THE SELECTION GUIDE.
Read the cautions described in NEC's "Miniature Relays" (ER0046EJ∗) when you choose relays
for your application.
The information in this document is subject to change without notice.
Document No. ER0304EJ2V0DS00 (2nd edition)
Date Published February 1999 M
Printed in Japan
©
1997
SoC chip debugging experience
Before introducing the bug, let me continue to explain the tips that are often used in debugging in wave. 1. Highlight the signal in Wave Select the signal in the Wave (left click once), press the let...
Jacktang DSP and ARM Processors
Self-powered switch realizes ZigBee transmission
Designing a ZigBee application for use with an energy harvesting source presents many challenges. One of the most difficult harvesters to work with is a self-powered switch, as very little energy is g...
fish001 Wireless Connectivity
Dynamic power management based on Linux: making embedded devices more energy-efficient
To differentiate their products in a crowded and competitive market, manufacturers of handheld devices often consider battery life and power management as key selling points for cell phones, PDAs, mul...
zbz0529 Power technology
STM32F103C8T6 serial port download
The minimum system board of STM32F103C8T6 (made by myself) can run after downloading the program using the serial port, but the program disappears after reset or power failure. I want to know how to u...
ojk1989 stm32/stm8
Why is there a difference between using JLINK emulation and not using it?
My STM32's USART1 is connected to a GSM module. When I use JLINK online simulation, I can see data coming through the serial port after sending a text message. But I download the code directly to the ...
keidy stm32/stm8
Components List of the 2013 National Undergraduate Electronic Design Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 03:45[/i] Official authentic...
生命奇迹泉 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 999  1903  1593  265  1566  21  39  33  6  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号