EEWORLDEEWORLDEEWORLD

Part Number

Search

DWR06-205

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size470KB,24 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

DWR06-205 Online Shopping

Suppliers Part Number Price MOQ In stock  
DWR06-205 - - View Buy Now

DWR06-205 Overview

Industrial Pressure Sensors FEMA

DWR06-205 Parametric

Parameter NameAttribute value
Product CategoryIndustrial Pressure Sensors
ManufacturerHoneywell
ProductPressure Switches
Operating Pressure0.1 bar to 0.6 bar
Pressure TypeDifferential
Accuracy< 1 %
Port SizeG 1/2, G 1/4
Operating Supply Voltage250 VAC
Maximum Operating Temperature+ 70 C
Minimum Operating Temperature- 25 C
Mounting StylePanel
Operating Supply Current8 A
PackagingBulk
Pressure PortPort
Factory Pack Quantity1
DWR
Pressure monitors
Especially suitable as a pressure monitor
or pressure limiter for fuel gases (DVGW
Worksheet G 260) and liquid fuels (e.g. fuel oil),
as well as for steam systems according to TRD
604 and hot-water systems to DIN EN12828,
systems in accordance to DIN EN12952-11
SIL 2 according IEC 61508-2
DWR625
Technical data
Pressure connection
External thread G 1/2 (pressure gauge
connection) to DIN 16 288 and internal thread
G 1/4 to ISO 228 Part 1 (for gas applications
internal thread permissible only up to 4 bar).
Switching device
Rugged housing (200) made of seawater-
resistant diecast aluminium.
Materials
Pressure bellows: Material no. 1.4571
Sensor housing: Material no. 1.4104 Switch
housing: GD AI Si 12 (DIN 1725)
Mounting position
Vertically upright and horizontal.
Ambient temperature at switching device
–25 to +70°C,
Medium temperature –25 to +70°C. The
maximum medium temperature at the pressure
sensor must not exceed the permitted ambient
temperature at the switching device.
Temperatures may reach 85°C for short periods.
Higher medium temperatures are possible
provided the above limit values for the switching
device are ensured by suitable measures
(e.g. siphon).
Mounting
Directly on the pressure line (pressure gauge
connection) or on a flat surface with two 4 mm
Ø screws.
Calibration
The DWR series is calibrated for rising pressure.
This means that the adjustable switching pressure
on the scale corresponds to the switching point at
rising pressure. The reset point is lower by the
amount of the switching differential. (See also
page 27, 2. Calibration at upper switching point).
In version ...-203 the switching differential is
adjustable. The basic calibration is maintained.
Bursting pressure
For all types
100 bar, verified by TÜV test.
Switching differential
For values see Product
Summary.
Contact arrangement
Single pole changeover
switch.
Switching
capacity
Normal
250 VAC 250 VDC 24 VDC
(ohm) (ind) (ohm) (ohm)
8A 5A
0.3 A
8A
Component tested for
Function
Direction of action
Sensor
Steam
Systems according to TRBS
Hot water
Systems according to DIN EN12828
Fuel gases
DVGW Worksheet G 260
Pressure tank
DIN EN764-7
Pressure monitor or pressure limiter
(with external interlock)
For maximum and minimum pressure monitoring
(DWFS, SDBFS)
"of special construction"
by testing with 2 million cycles.
Product Summary
Type
Setting range
Switching
differential
(mean values)
Maximum
working
pressure
Dimen-
sioned
drawing
p. 25 + 26
1 + 15
1 + 18
63 bar
1 + 16
63 bar
1 + 16
Protection class
IP 54 according to
DIN 40 050
-DWR
see page 69
s
tested
DVGW
TÜV
Protection Class:
IP 54
Accessories
Solenoid valves
Switching differential adjustable
DWR06–203
0.1…0.6 bar
0.08…0.5
DWR1–203
0.2…1.6 bar
0.15…0.6
DWR3–203
0.2…2.5 bar
0.17…1.2
DWR6–203
0.5…6 bar
0.3…1.4
DWR625–203
0.5…6 bar
0.4…2.5
DWR16–203
3…16 bar
0.75…3.15
DWR25–203
4…25 bar
1.3…6.0
DWR40–203
8…40 bar
2.3…6.6
bar
bar
bar
bar
bar
bar
bar
bar
6 bar
16 bar
25 bar
1 + 15
1 + 18
1 + 17
Flow monitors
Pressure monitors without differential adjustment
DWR06
0.1…0.6 bar
0.04 bar
DWR1
0.2…1.6 bar
0.06 bar
DWR3
0.2…2.5 bar
0.1 bar
DWR6
0.5…6 bar
0.2 bar
DWR625
0.5…6 bar
0.25 bar
DWR16
3…16 bar
0.5 bar
DWR25
4…25 bar
1.0 bar
DWR40
8…40 bar
1.3 bar
6 bar
16 bar
25 bar
1 + 17
Temperature sensors
Thermostats
Pressure transmitters
and DIN EN12953-9. The DWR is used to
monitor maximum and minimum pressures.
This pressure switch is "of special construction"
and has been tested with 2 million operating
cycles. TÜV and DVGW tests exists.
Pressure switches
Mechanical pressure switches
Tested to PE Directive 97/23/EC
59
Some problems with quartus ii calling modelsim simulation
Hello to all the FPGA enthusiasts, does anyone know what is wrong with the following error? : Below is the error that occurs when quartus calls modelsim simulation, and the waveform cannot be displaye...
xuhongming FPGA/CPLD
A match made in heaven: analog components and the msp 432
[font=微软雅黑][size=3]Reprinted from: deyisupport[/size][/font][font=微软雅黑][size=3] [/size][/font] [align=left][color=#000][font=微软雅黑][size=3]Microcontrollers and analog components complement each other. ...
maylove Microcontroller MCU
Regarding the use of scroll bars in Dialog.
Use EVC4+WINCE.NET to scroll the scroll bar using the following code: void C2MSetting::OnVScroll(UINT nSBCode, UINT nPos, CScrollBar* pScrollBar) { int nDelta; int nMaxPos = m_rcOriginalRect.Height() ...
5880527 Embedded System
Electronic Design Competition Component Selection
[i=s]This post was last edited by paulhyde on 2014-9-15 09:35[/i] [size=12pt][/size] [size=12pt][font=Times New Roman][/font][/size] [size=12pt][font=Times New Roman]2009[/font][/size][font=宋体][size=1...
shuining Electronics Design Contest
It was found that ATMEL Studio was not stable
When using ATMEL Studio for simulation, you often encounter a phenomenon that after several simulations, you may not be able to enter the program file when you start the simulation again. You must exi...
dcexpert Microchip MCU
Beacon Application in Wearable Devices – Android & Bluetooth
According to IDC, the smart wearable technology market will grow five times in 2015 compared to 2014, with product shipments expected to exceed 25 million units, and most of them will use Bluetooth Sm...
fish001 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 541  2017  1392  994  1193  11  41  29  21  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号