Specially designed for oxygen service, supply and transport applications Kavlico’s P1E pressure sensor apply
ISO15001 cleaning procedures and are delivered with a protection cap on the thread in an individual hermetically
sealed packaging. P1E sensors are approved to be used in medical gas service applications such as breathing
oxygen and high pressure oxygen service and distribution applications.
The sensor offers a compact, low weight and a hermetically sealed design that incorporates Kavlico´s thin film strain
gauge technology in a 304 stainless steel housing. Due to the hermetically sealed design the sense element is
impervious to almost any media, and does not require an internal seal. The robust design ensures high repeatability
and long term stability. P1E sensors are designed for a wide range of liquid and gaseous media and a wide
temperature range from -30° C to +100°C (media to 120°C). To ensure a world-wide usage the senor is cULus
listed and CE certified.
www.kavlico.com
Technical Specifications
Pressure Ranges
from 0 to …
Proof pressure
Burst pressure
bar (gage)
bar (gage)
bar (gage)
10
20
100
16
32
160
25
50
200
100
200
600
250
375
1000
400
600
1600
Physical
Operating Life Cycle
Vibration Resistance
Shock Resistance
Drop Test
Weight
Ingress Protection
Medium Temperature
Storage Temperature
Media
min. 10 million full pressure cycles over the full range
IEC 60068-2-64 (RANDOM) 20 PSD
25 g minimum according to DIN EN 60068-2-27
1 meter drop on concrete as per SAE J1455 / DIN EN 60068-2-3-1
Approx. 50 grams (without mating connector)
IP 65 or IP67 - depending on electrical connector
-30°C to + 120°C
-30°C to + 100°C
All class II fluids and gases compatible with stainless steel 304 (1.4301)
Environmental Temperature
-30°C to + 100°C
Performance
Accuracy
*1
Non-linearity
*2
Non-repeatability
1-year stability
Temp. Coefficients - Zero
Temp. Coefficients - Span
*1
*2
≤
0.5 % of span
*3
0.2 % of span
*3
0.1 % of span
0.2 % of span
0.2 % of span / 10 K within temperature range 0°C to + 80°C
0.2 % of span / 10 K within temperature range 0°C to + 80°C
Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with pressure port down.
BFSL according to IEC 61298-2 reference conditions to EN 61298-1
Others on request
*3
www.kavlico.com
Data Sheet P1E
2
Electrical
Output Signal
Operating Supply Signal
Power Consumption
Overvoltage Protection
Short-circuit Proofness
Insulation Voltage
Load
Response Time
*4
4…20 mA
8-30 VDC
≤
600 mW
min. 33 VDC
not applicable
500 VDC
≤
(Vsup-8 VDC)/(0.02 A) [Ω]
≤
2 ms max. to 63% of full scale pressure with step change on input
Reverse Polarity Protection
Yes
*4
for min. 10 seconds on assigned pins
Approvals & Certificates
Pressure equipment directive 97/23/EC
EMC directive 2004/108/EEC, EN 61 326 Emission (Group 1, Class B)
and Immunity (industrial locations), EMI, ESD protected
In accordance with ISO 15001
2011/65/EU ROHS Directive
CE Compliance
Cleanliness specification
ROHS
www.kavlico.com
Data Sheet P1E
3
Dimensions
Pressure Sensor with Electrical Connection
Dimensions in mm [Inch]
M12 Pin Call Outs
Output
4-20 mA
Pin 1
Vsup
Pin 2
...
Pin 3
lout
Pin 4
...
18 mm Pin Call Outs
Output
4-20 mA
Pin 1
Vsup
Pin 2
lout
Pin 3
...
Pin 4
...
9.4 mm Pin Call Outs
Output
4-20 mA
Pin 1
Vsup
Pin 2
lout
Pin 3
...
Pin 4
...
Pressure Connections and Recommended Installation Torque
Dimensions in mm [Inch]
Name
Thread
Torque
G1/4A DIN 3852-A
External
20 Nm
www.kavlico.com
Data Sheet P1E
4
How to Order
P1E
Pressure Ranges BarG
010
016
025
100
250
400
0 – 10
0 – 16
0 – 25
0 – 100
0 – 250
0 – 400
100
1
A
4
A
Built-in Electrical Connection
A
Compatible with DIN 175301-803 A (18 mm)
Sensor delivered without mating connector
Output
1
4 - 20 mA
B
GDS 307 Industrial Standard (9.4 mm)
Sensor delivered without mating connector
C
M12 - 4 pole
assembly
Sensor delivered without mating connector cable
External Seal ring
A
None
C
Aluminium Washer G1/4
washer will be fixed with plastic cap
D
Copper Washer G1/4
washer will be fixed with plastic cap
Pressure Connection (port)
4
G1/4”A DIN 3852-A
Example:
P1E-100-1-A-4-A
Description:
P1E Sensor, 0 - 100 bar Gage, 4…20 mA Electrical Output, no external seal ring, G1/4” A DIN 3582-A Pressure
Connection, with Built-in Connector Compatible with DIN175301-803 A (18mm)
Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring
conditions. Non-compliance can result in serious injury and/or damage to the equipment.
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of
contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use
or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for
the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition,
deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not
been expressly agreed by us prior to the sale of our products.
[FPGA entry to actual combat] Spectrum relocation process in the upsampling process of wireless communication; Students who do not understand the knowledge points in the video can ask questions in the...
My serial port program has encountered a problem, and I have no idea how to solve it. Please help me. I use a 256-byte buffer to store and access commands sent by users from the terminal. If I enter t...
1. Program (I) #define OSC_FREQ (11059200UL) //Oscillator frequency (Hz) #define OSC_PER_INST (12) //Number of oscillation periods per instruction //Data type #define tByte unsigned char #define tWord...
[i=s]This post was last edited by dontium on 2015-1-23 13:27[/i]Fairchild introduced the low -power single-chip switching power supply FSD200, which has an output power of 7W at 230V±15%, a dual-in-li...
My graduation project is the design and simulation of the carbon dioxide and light intensity control system in the greenhouse. Oh, I am done for. I am really going crazy. I can't install Protues on Wi...
introduction
Since the beginning of the 21st century, the world of information has changed rapidly. Maybe a high-tech product will be released today and a better similar product will be releas...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
The automotive lighting and signal control system is responsible for controlling the vehicle's lighting, signal lights, electric horns, reversing and brake buzzers. Traditional automotive lighting...[Details]
The typical fault troubleshooting listed below is for reference of maintenance personnel.
When the computer is turned on, the indicator light is off and there is no screen display
Mainte...[Details]
With concerns about the growing energy crisis, motor efficiency has become an important and timely topic. This is because motors use 63% to 70% of the electricity produced in the United States and ...[Details]
1. Overview
At present, an information revolution is in the ascendant around the world, led by microelectronics, computers and communication technologies, and centered on information technolog...[Details]
1 Introduction
With the improvement of people's quality of life, lamps are no longer just basic indoor lighting tools, but also a kind of practical art for architectural decoration. When ther...[Details]
Overview
By transmitting ultrasonic energy into the human body and receiving and processing the returning reflected signals, phased array ultrasound systems can generate images of organs and s...[Details]
introduction
LEDs continue to gain popularity in automotive applications, thanks to their long lifespan and the flexibility they offer for body styling and interior design. Some may be surpris...[Details]
1 What is an LED floodlight?
LED downlights are also called spotlights, projection lamps, and spotlights. They are mainly used for architectural decorative lighting and commercial space lighti...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
Infrared remote control is widely used in home appliances, but the remote controls produced are not compatible with each other. The universal remote controls commonly seen on the market can only co...[Details]
Applying fieldbus technology on new beer production lines is the first choice for large beer companies with strong management level and technical strength. Guangzhou Zhujiang Beer Group Co., Ltd. i...[Details]