EEWORLDEEWORLDEEWORLD

Part Number

Search

PST060RG12S

Description
Industrial Pressure Sensors FEMA
CategoryThe sensor   
File Size327KB,8 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

PST060RG12S Online Shopping

Suppliers Part Number Price MOQ In stock  
PST060RG12S - - View Buy Now

PST060RG12S Overview

Industrial Pressure Sensors FEMA

PST060RG12S Parametric

Parameter NameAttribute value
Product CategoryIndustrial Pressure Sensors
ManufacturerHoneywell
ProductPressure Switches
Operating Pressure0 bar to 60 bar
Pressure TypeDifferential
Accuracy0.5 %
Output TypeDigital / Analog
Port SizeG 1/2
Output Voltage36 VDC
Operating Supply Voltage36 V
Maximum Operating Temperature+ 60 C
Minimum Operating Temperature- 20 C
Mounting StylePanel
Operating Supply Current100 mA
PackagingBulk
Pressure PortPort
Factory Pack Quantity1
ELECTRONIC PRESSURE SWITCHES
PRODUCT DATA
PST... and PST...-R
FEATURES
polybutylene terephtalate (PBT)
-20...+60 °C
-35...+80 °C
-20...+100 °C
0...95%, non-condensing
0.5% of final value
0.3% per 10 K (0.5% per 10 K
in case of 250/400/600 mbar)
Total weight
380 grams
Parts in contact with medium
High-pressure versions 1.4571 + 1.4542
Low-pressure / flush
1.4571 + 1.4435
Process connection
Manometer connection G1/2" external thread
Flush connection
G3/4" external thread
Electrical connection
PST series
5-prong M12 plug, A-coded as per
DIN IEC 60947-5-2
PST...-R series
Extra 3-prong M12 plug
Protection class
II as per EN 60335-1
Protection type
IP65 as per EN 60529
Climate class
C as per DIN IEC 60654
Power supply
15...36 Vdc, max. 100 mA
EMC
compatible as per EN61326/A1
Switch outputs (all versions)
Open-Collector outputs Two; configurable as high-side/
low-side or as push-pull switches,
max. load: 250 mA / 15...36 Vdc
Reaction time
30 ms
Switching difference
(SP and RP) configurable
Relay outputs (PST...-R series)
Contact type
1 switch-over contact
Min. electrical lifetime 250,000 switching cycles
Switching performance, gold contacts (AgSn0
2
+Au)
AC1 (resistive)
1.5 VA (24 Vdc / 60 mA, 230 Vac /
6.5 mA)
AC15 (inductive)
unsuitable
Max. switch-on current 60 mA for < 5 ms
Min. switching perf.
50 mW (either > 5 V or > 2 mA)
Switching performance, silver contacts (AgSn0
2
)
AC1 (resistive)
690 VA (230 Vac / 3 A)
AC15 (inductive)
230 VA (230 Vac / 1 A)
Max. switch-on current 30 A for < 5 ms
Min. switching perf.
500 mW (> 12 V or > 10 mA)
Diagnostic output
Output configuration
warning output (plug 2),
max. 20 mA, 15...36 Vdc
Transmitter output (analog output)
Voltage / current
0...10 V and 4...20 mA,
configurable in expert mode
Transient response
approx. 300 ms
Housing and back
Max. ambient temp.
Storage temperature
Temperature, medium
Relative air humidity
Accuracy, total
Medium temp. drift
APPLICATION
Honeywell FEMA's PST and PST...-R series Electronic
Pressure Switches require adjustment (configuration and
parameterization) in only two modes (the basic mode and
the expert mode) and are suitable for an extremely wide
range of applications, including the precision-adjustment
and monitoring of system pressures in the field of plant
construction, fluidics, process technology, and pneumatics,
as well as in the monitoring and control of pumps and
compressors.
Due to their monitored sensors with a standardized warning
output, these devices are suitable for use in manufacturing
lines in the automotive industry as well as in the area of
machine tool construction. These switches provide
sufficient accuracy (0.5% of final value) for measurement
monitoring in many laboratory applications.
®
U.S Registered Trademark
Copyright © 2009 Honeywell Inc.
All Rights Reserved
EN0B-0346GE51 R0609
I made a 485 communication board, can you help me take a look?
Professional MCU software and hardware developmentAddress: Nangang District Convention and Exhibition Center, HarbinQQ: 909987836Tel: 13766867932The download attachments include: schematic diagram, ci...
tzl MCU
About OP07
Can someone tell me what the diodes in this circuit do, especially why IN4148 is added to the feedback and output of OP07?...
nandehutu520 Analog electronics
How to set read protection for TM4C123
How to set read protection for TM4C123? The functions provided by the library are FlashProtectSet(0x0,FlashExecuteOnly); FlashProtectSave(); As long as protection is set, the chip will not work.Has an...
autodash Microcontroller MCU
A method for realizing a matrix keyboard using N+1 lines
[font=宋体] As the most commonly used input device, keyboard input still has its irreplaceable role. [font=宋体][size=12pt][color=#000000]First, let's make a brief introduction to the traditional keyboard...
tiankai001 MCU
ADuC7061 interrupt mode realizes serial communication
/****************************** * name: * function: * return: ********* *************************/ #include "string.h" #include "global.h" #include "function.h" #include #include unsigned char UartDat...
zhoouauruheng ADI Reference Circuit
Issues that need attention when using the interrupt system of PIC16F87X microcontroller
Abstract: The hardware structure and instruction system of the PIC series microcontroller developed by Microchip Technology Inc. in the United States adopt a unique design method. It has made some gro...
rain Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 960  950  1674  915  1147  20  34  19  24  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号