EEWORLDEEWORLDEEWORLD

Part Number

Search

PX2AM1XX050PAAAX

Description
Industrial Pressure Sensors PX Pressure
CategoryThe sensor   
File Size2MB,10 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

PX2AM1XX050PAAAX Online Shopping

Suppliers Part Number Price MOQ In stock  
PX2AM1XX050PAAAX - - View Buy Now

PX2AM1XX050PAAAX Overview

Industrial Pressure Sensors PX Pressure

PX2AM1XX050PAAAX Parametric

Parameter NameAttribute value
Product CategoryIndustrial Pressure Sensors
ManufacturerHoneywell
RoHSDetails
ProductTransducers
Accuracy0.25 %
Output TypeAmplified
Factory Pack Quantity1
Heavy Duty Pressure Transducers
PX2 Series, 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi
FEATURES
50069942
Datasheet
Datasheet
Issue
I
• Pressure range: 1 bar to 70 bar | 100 kPa to 7 MPa | 15 psi to
1000 psi
• Pressure reference: Absolute, sealed gage or vented gage
• Pressure port types: 7/16-20 UNF 1/4 in 45° Flare Female
Schrader (SAE J512), 7/16-20 UNF 45° Flare Male (SAE
J513), 7/16-20 UNF 37° Flare Male (SAE J514), G1/4 (ISO
1179-3), G1/8 (ISO 1179-3), M12 x 1.5 (ISO 6149-3),
1/4-18 NPT, 1/8-27 NPT, 9/16-18 UNF, (SAE J1926-3), or
7/16-20 UNF (SAE J1926-3)
• Electrical connector types: Metri-Pack 150 (UL 94 HB or V-0
options), Micro M12, DIN, Deutsch, or cable harness
DESCRIPTION
Honeywell’s PX2 Series Heavy Duty Pressure Transducers
are a portfolio of configurable pressure sensors that use
piezoresistive sensing technology with ASIC (Application
Specific Integrated Circuit) signal conditioning in a stainless
steel housing. The PX2 Series is fully calibrated and
compensated for offset, sensitivity, temperature effects and
non-linearity using the on-board ASIC. These transducers
measure absolute, sealed gage, or vented gage pressure. The
absolute versions have an internal vacuum reference and
an output value proportional to absolute pressure, sealed
gage versions have an internal pressure reference of one
atmosphere at sea level, and vented gage versions measure
pressure with respect to ambient pressure. They are RoHS
compliant and are designed and manufactured according to
ISO 9001 standards.
VALUE TO CUSTOMERS
• Media compatibility: Common HFC (hydrofluorocarbon)
refrigerants such as R410A and R134A, next generation low
global warming potential (GWP) refrigerants such as R448A
(Solstice® N40), R32 and R1234ZE, engine oil, petroleum-
based hydraulic fluids, DOT 3 brake fluid, and dry air. For
ammonia and other corrosive media, see Honeywell’s SPT
Series.
• Enhanced durability: The PX2 Series can operate in the
rigorous environments commonly found in HVAC/R and air
compressor applications. The sensor can survive at least 10
million pressure cycles and has an ingress protection rating
up to IP69K.
PORTFOLIO
Honeywell’s PX2 Series joins the PX3 Series, MLH Series, and
SPT Series heavy duty pressure transducers.
The PX2 Series is not recommended for use with media
involving water, saturated air such as steam and vapor, and
ammonia.
(1 m, 2 m, 3 m, or 5 m)
• Total Error Band: ±2.0 %
• Operating and compensated temperature range: -40°C to
125°C [-40°F to 257°F]
• Response time: <2 ms
• Life: Minimum of 10 million cycles to operating pressure
• Output transfer function: Ratiometric, regulated or current
• Mechanical shock rating: 100 G per MIL-STD-202F, Method
213B, Cond. F
• Vibration rating: 20 G sweep, 10 Hz to 2000 Hz
• Ingress protection: Up to IP69K
• Radiated immunity protection: Up to 100 V/m (ISO 11452-2)
• Flame retardant options: UL 94 HB standard on all electrical
terminations; UL 94 V-0 available upon request
POTENTIAL APPLICATIONS
• Industrial: Refrigerant pressure monitoring in HVAC/R
systems; air compressor system pressure
• Transportation: Air system monitoring; hydraulic oil pressure
monitoring
Sensing and Internet of Things
This file should only be compiled with iccavr or aavr with processor option -v1
#error This file should only be compiled with iccavr or aavr with processor option -v1 Has anyone encountered this problem with IAR AVR?...
glabhenly Embedded System
Radio Communications
How to get started with RT radio communication~~~...
liuyiyuan Embedded System
Altium Designer 16 Copper Pour
[i=s]This post was last edited by yqm on 2016-3-9 10:03[/i] I installed Altium Designer 16 today and found that the quick edit copper pour tool in AD9.4 is gone. How can I edit the copper pour in the ...
yqm PCB Design
EMC Methods in Designing Circuit Control Boards for Household Appliances
The small size and low cost of home appliance control boards mean that high-cost materials will not be used in the circuit to solve the electromagnetic interference problem. The interference of home a...
探路者 Mobile and portable
Questions about ARM interrupt processing - Questions in Chapter 9 of "ARM Embedded System Development - Software Design and Optimization"
Happy New Year, everyone! Haha, I have a little confusion here. Let's discuss it together. This question is from the book "ARM Embedded System Development - Software Design and Optimization". See belo...
liloude ARM Technology
Looking for the schematic diagram of LPCXpresso LPC1227 REVB
I can't find it on the official website. Also, how to install the LPC-Link driver? Thank you....
wudayongnb NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2762  1025  1621  75  977  56  21  33  2  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号